共找到 476 条与 火警监视、报警与消防调度系统 相关的标准,共 32 页
Components of automatic fire detection systems; Part 6: Heat sensitive detectors; rate of rise point detectors without a static element
Signs for orientation at automatic fire detectors
Signs for orientation at automatic fire detectors
Components of automatic fire detection systems; Part 9: Fire sensitivity test
Components of automatic fire detection systems; Part 8: High temperature heat detectors
Components of automatic fire detection systems; Part 6: Heat sensitive detectors; rate of rise point detectors without a static element
Components of automatic fire detection systems; Part 7: Point type smoke detectors; Detectors using scattered light, transmitted light or ionization
Manual call point; explosion proof, for use in operation roomsBrandmelder nach dieser Norm müssen gem?? der ? Verordnung über elektrische Anlagen in explosionsgef?hrdeten R?umen (siehe Bundesgesetzblatt (BGB1. I, Seite 697) vom 15. August 1963) der Bau
Manual call point; explosion proof, for use in operation rooms
Components of automatic fire detection systems. Part 5: Heat sensitive detectors; Point detectors containing a static element
Components of automatic fire detection systems; Part 1: Introduction
Acoustics-sound signal for emergency evacuation.
Fire fighting equipment; fixing for projectors; boring, pivot, jointDas in dieser Norm festgelegte Gelenkstück ist für Arbeitsstellen-Scheinwerfer nach DIN 14 644 und Stative nach DIN 14 683 bestimmt.
Fire fighting equipment; fixing for projectors, boring pivot, joint
Advice on the construction of simple smoke viewers, particularly suitable for fitting to individual flues to supplement information provided by more complex instruments installed in a common flue.
Recommendations for the construction of simple smoke viewers
Requirements for the construction and operation of instruments designed to give an alarm when smoke emission from a chimney exceeds a chosen Ringelmann shade.
Specification for simple smoke alarms and alarm metering devices
This specification describes the requirements for the design,manufacture, testing and installation of radiation sensing (surveillance type) fire warning systems far use i n aircraft.
FIRE WARNING SYSTEMS, AIRCRAFT, RADIATION SENSING TYPE, TEST AND INSTALLATION OF
Heat detectors for fire protective signaling systems intended for installation in ordinary indoor and outdoor locations.
UL Standard for Safety Heat Detectors for Fire Protective Signaling Systems COMMENTS DUE: FEBRUARY 18, 2008
UL Standard for Safety Control Units and Accessories for Fire Alarm Systems (Tenth Edition; Reprint with revisions through and including March 29@ 2018)
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号