(a) Definitions. As used in this part, the units of radiation dose are:

Energy. Part20:Standards for protection against radiation. Subpart A:General Provisions. Section20.1004:Units of radiation dose.

ICS
CCS
F00
发布
1991-03-21
实施
1991-03-21

(a) The regulations in this part establish standards for protection against ionizing radiation resulting from activities conducted under licenses issued by the Nuclear Regulatory Commission. These regulations are issued under the Atomic Energy Act of 1954, as amended, and the Energy Reorganization Act of 1974, as amended.

Energy. Part20:Standards for protection against radiation. Subpart A:General Provisions. Section20.1001:Purpose.

ICS
CCS
F00
发布
1991-03-21
实施
1991-03-21

Nothing in this subpart relieves the licensee from complying with other applicable Federal, State, and local regulations governing any other toxic or hazardous properties of materials that may be disposed of under this subpart.

Energy. Part20:Standards for protection against radiation. Subpart K:Waste Disposal. Section20.2007:Compliance with environmental and health protection regulations.

ICS
CCS
F00
发布
1991-03-21
实施
1991-03-21

A licensee or applicant for a license may apply to the Commission for approval of proposed procedures, not otherwise authorized in the regulations in this chapter, to dispose of licensed material generated in the licensee’s activities. Each application shall include:

Energy. Part20:Standards for protection against radiation. Subpart K:Waste Disposal. Section20.2002:Method for obtaining approval of proposed disposal procedures.

ICS
CCS
F00
发布
1991-03-21
实施
1991-03-21

(a) Each licensee shall maintain records of the radiation protection program, including:

Energy. Part20:Standards for protection against radiation. Subpart L:Records. Section20.2102:Records of radiation protection programs.

ICS
CCS
F00
发布
1991-03-21
实施
1991-03-21

本标准规定了质量管理手册编写的基本要求和方法。 本标准适用于在合同或非合同环境下核工业系统产品研制,生产单位编写《手册》,工程设计及承建单位在编写《手册》时亦可参照使用。

Guidelines for the preparation of nuclear industry quality management manual

ICS
CCS
F00
发布
1990-08-10
实施
1991-01-01

The following casks are approved for storage of spent fuel under the conditions specified in their Certificates of Compliance.

Energy. Part72:Licensing requirements for the independent storage of spent nuclear fuel, high-level radioactive waste, and reactor-related greater than class c waste. Subpart K:General License for Storage of Spent Fuel at Power Reactor Sites. Section72.21

ICS
CCS
F00
发布
1990-06-18
实施
1990-06-18

(a) Except as provided under a regional licensing program identified in paragraph (b) of this section, an applicant or licensee or facility licensee shall submit any communication or report concerning the regulations in this part and shall submit any application filed under these regulations to the Commission as follows:

Energy. Part55:Operators’ licenses. Subpart A:General Provisions. Section55.5:Communications.

ICS
CCS
F00
发布
1989-05-29
实施
1989-05-29

Applicants for construction permits, manufacturing licenses, operating licenses, import and export licenses, approvals of facility standard reference designs, re-qualification and replacement examinations for reactor operators, and special projects and holders of construction permits, licenses, and other approvals shall pay fees for the following categories of services:

Energy. Part170:Fees for facilities, materials, import and export licenses, and other regulatory services under the atomic energy act of 1954, as amended. Section170.21:Schedule of fees for production and utilization facilities, review of standard referen

ICS
CCS
F00
发布
1988-12-29
实施
1988-12-29

(a) Each operator shall take respirable dust samples of the concentration of respirable dust in the active workings of the mine as required by this part with a sampling device approved by the Secretary and the Secretary of Health and Human Services under part 74 (Coal Mine Dust Personal Sampler Units) of this title.

Mineral Resources. Part70:Mandatory health standards—underground coal mines. Section70.201:Sampling; general requirements.

ICS
CCS
F00
发布
1982-06-29
实施
1982-06-29

(a) Approved sampling devices shall be operated at the flowrate of 2.0 L/min if using a CMDPSU; at 2.2 L/min if using a CPDM; or at a different flowrate recommended by the manufacturer.

Mineral Resources. Part70:Mandatory health standards—underground coal mines. Section70.205:Approved sampling devices; operation; air flowrate.

ICS
CCS
F00
发布
1982-06-29
实施
1982-06-29

(a) Each operator shall take respirable dust samples of the concentration of respirable dust in the active workings of the mine as required by this part with a sampling device approved by the Secretary and the Secretary of Health and Human Services under part 74 (Coal Mine Dust Personal Sampler Units) of this title.

Mineral Resources. Part90:Mandatory health standards—coal miners who have evidence of the development of pneumoconiosis. Section90.201:Sampling; general requirements.

ICS
CCS
F00
发布
1980-12-05
实施
1980-12-05

(a) The respirable dust sampling required by this part shall be done by a certified person.

Mineral Resources. Part90:Mandatory health standards—coal miners who have evidence of the development of pneumoconiosis. Section90.202:Certified person; sampling.

ICS
CCS
F00
发布
1980-12-05
实施
1980-12-05

(a) Approved sampling devices shall be maintained and calibrated by a certified person

Mineral Resources. Part90:Mandatory health standards—coal miners who have evidence of the development of pneumoconiosis. Section90.203:Certified person; maintenance and calibration.

ICS
CCS
F00
发布
1980-12-05
实施
1980-12-05

The concentration of respirable dust shall be determined by dividing the weight of dust in milligrams collected on the filter of an approved sampling device by the volume of air in cubic meters passing through the filter and then converting that concentration to an equivalent concentration as measured with an MRE instrument. To convert a concentration of respirable dust as measured with an approved sampling device to an equivalent concentration of respirable dust as measured with an MRE instrument, the concentration of respirable dust measured with the approved sampling device shall be multiplied by the constant factor prescribed by the Secretary for the approved sampling device used, and the product shall be the equivalent concentration as measured with an MRE instrument.

Mineral Resources. Part71:Mandatory health standards—surface coal mines and surface work areas of underground coal mines. Section71.206:Approved sampling devices; equivalent concentrations.

ICS
CCS
F00
发布
1980-12-05
实施
1980-12-05

(a) Each operator shall take respirable dust samples of the concentration of respirable dust in the active workings of the mine as required by this part with a sampling device approved by the Secretary and the Secretary of Health and Human Services under part 74 (Coal Mine Dust Personal Sampler Units) of this title.

Mineral Resources. Part71:Mandatory health standards—surface coal mines and surface work areas of underground coal mines. Section71.201:Sampling; general requirements.

ICS
CCS
F00
发布
1980-12-05
实施
1980-12-05

(a) The respirable dust sampling required by this part shall be done by a certified person.

Mineral Resources. Part71:Mandatory health standards—surface coal mines and surface work areas of underground coal mines. Section71.202:Certified person; sampling.

ICS
CCS
F00
发布
1980-12-05
实施
1980-12-05

(a) If an operator abates a violation of § 90.100 (Respirable dust standard) or § 90.101 (Respirable dust standard when quartz is present) by reducing the respirable dust level in the position of the part 90 miner, the operator shall submit a written respirable dust control plan for that part 90 miner in that position within 15 calendar days after thecitation is terminated to the District Manager for approval. The respirable dust control plan and revisions thereof shall be suitable to the conditions and the mining system of the coal mine and shall be adequate to continuously maintain respirable dust within the permissible concentration for the part 90 miner in the position identified in the citation.

Mineral Resources. Part90:Mandatory health standards—coal miners who have evidence of the development of pneumoconiosis. Section90.300:Respirable dust control plan; filing requirements.

ICS
CCS
F00
发布
1980-12-05
实施
1980-12-05

Each operator shall continuously maintain the average concentration of respirable dust in the mine atmosphere during each shift to which each miner in the active workings is exposed at or below 2.0 milligrams of respirable dust per cubic meter of air. Concentrations shall be measured with an approved sampling device and expressed in terms of an equivalent concentration determined in accordance with § 71.206 (Approved sampling devices; equivalent concentrations).

Mineral Resources. Part71:Mandatory health standards—surface coal mines and surface work areas of underground coal mines. Section71.100:Respirable dust standard.

ICS
CCS
F00
发布
1980-12-05
实施
1980-12-05

(a) Whenever a Part 90 miner is transferred in order to meet the respirable dust standard in § 90.100 (Respirable dust standard) or § 90.101 (Respirable dust standard when quartz is present), the operator shall transfer the miner to an existing position at the same coal mine on the same shift or shift rotation on which the miner was employed immediately before the transfer. The operator may transfer a Part 90 miner to a different coal mine, a newly-created position or a position on a different shift or shift rotation if the miner agrees in writing to the transfer.