共找到 71 条与 防护用具与设备 相关的标准,共 5 页
この規格は,原子力関連の事業所において,放射性汚染防護のために使用する放射性汚染防護用作業靴(以下,作業靴という。)について規定する。
Protective footwear for radioactive contamination
The General Services Administration has authorized the use of this commercial item description as a replacement for Military Specifications MIL-V-16720E and MIL-V-16721D which are cancelled.
ARM SLEEVE, RADIOACTIVE CONTAMINANTS, PROTECTIVE [Use: DLA A-A-50385 CANC NOTICE 1, DLA A-A-50385]
この規格は,原子力施設などにおいて,放射性汚染に対する防護を目的として使用する防誇服のうち,換気加圧服及び非換気非加圧服について規定する。
Clothing for protection against radioactive contamination
This specification covers the requirements for type of radioactive contaminant protective hood made of polyester and cotton twill cloth.
HOOD, RADIOACTIVE CONTAMINANTS, PROTECTIVE
Decontamination of radioactively contaminated surfaces. Testing of decontamination agents for textiles.
Enclosures for protection against ionizing radiation. Lead shielding units for 150 mm, 200 mm and 250 mm thick walls. Part 1 : chevron units of 150 mm and 200 mm thickness.
Instruments measuring over a more limited energy range fall within the scope provided they cover at least the range of 80 keV to 1,5 MeV. The assemblies comprise at least a detector sub-assembly and a measuring sub-assembly. Specifies standard general ch
Radiation protection instrumentation; installed dose ratemeters, warning assemblies and monitors; X and gamma radiation of energy between 50 keV and 7 MeV
Specifies the properties of the various lead units used in the construction of basic units (bricks, posts) and functional units (aperture bricks, windows, sphere units, plugs and reducing units). Annex A is for information only.
Enclosures for protection against ionizing radiation; lead shielding units for 150 mm, 200 mm and 250 mm thick walls; part 1: chevron units of 150 mm and 200 mm thickness
Design applications for grounding, bonding and shielding
Radioactive Contamination Protective Gloves
Prezentul standard stabile?te dimensiunile de baz? ale dulapurilor ?i structurilor de fixare sau combina?ii ale acestora pe care se pot monta sertare ?i panouri de 482,6 mm, destinate echipamentelor electronice.
Electronic equipments. Cabinets and pitches of rack structures, series 482,6 mm. Dimensions
Ihis specification mers the rquhemmts for construction and testhg of the Radiac Detector DF236/pDw-75, individuai, indrrect reading, neutr0nqam-n dmhter for detecting, measuring neutr0n and gamma doses received by individual soldiers operating in nuclear environments.
RADIAC DETECTOR DT-236( )/PDR-75
Design, inspection, selection and use of protective clothing against radioactive contamination
This standard specifies dimensions and requirements for glove boxes. The purpose of the standard is to give uniform guidelines to manufacturers, suppliers, users and authorities on dimensions and requirements, in particular on the leak-tightness of gove boxes. The standard shall be applied to glove boxes which are used for handling radioactive materials emitting ionizing radiation. The standard shall not be applied to glove boxes used in processes on a technical state.#,,#
Laboratory equipment; glove boxes; dimensions and requirements
RADIATION PROTECTION. CLOTHING FOR PROTECTION AGAINST RADIOACTIVE CONTAMINATION. DESIGN,SELECTION,TESTING AND USE.
Gives the characterisitcs of two types of clothing: ventilated-pressurized garments and unventilated-unpressurized garments. These characteristics include the manufacture materials, design and size, accessories, breathing air supply and internal ventilation. Annex A describes a test method according to which any new type of garment can be assigned a protection factor that makes it easier for the user to make a choice. Annexes B and C give methods for measuring leak tightness and air supply flow rates of ventilated-pressurized garments. Annex F gives, for guidance, recommendations for choosing protective clothing.
Radiation protection; Clothing for protection against radioactive contamination; Design, selection, testing and use
This standard specifies requirements relating to components of contamination protection boxes. These boxes are used in hot cells with shieldings made of lead bricks and special components complying with DIN 25407 part 1 and 2.; The components complying with this standard and those complying with DIN 25407 part 1 and 2 are used to build hot cells with sealed interiors and surrounding lead shieldings (Alpha-Gamma-Technique).
Components for contamination protection boxes; nozzles, rings for remote handling tongs, windows and posting systems
This specification covers the requirements for protective arm sleeves made of flexible vinyl plastic film.
ARM SLEEVE, RADIOACTIVE CONTAMINANTS, PROTECTIVE [Use: DLA A-A-50385 CANC NOTICE 1, DLA A-A-50385]
Gives general advice on the selection of materials which may become contaminated by radioactive substances and which require subsequent decontamination. Appendix A provides information relating to the radiation resistance of materials.
Surface materials for use in radioactive areas - Guide to the selection of materials