F84 辐射防护仪器 标准查询与下载



共找到 379 条与 辐射防护仪器 相关的标准,共 26

This International Standard specifies the classification, general design requirements, performance characteristics and test procedures for in vivo counting systems for detecting trace amounts of radionuclides in the bodies of persons working in nuclear power plants, laboratories and facilities handling radionuclides, and inhabitants living on territory which may be contaminated by either naturally occurring or artificial radionuclides. The purpose is to determine the dose equivalent to organs and the effective dose of internal radiation for the whole body. This standard is applicable both to equipment with spectroscopic capabilities and instruments for rapid screening for gross internal contamination only. This standard is applicable to instruments for the monitoring of certain critical organs (for example, lungs, thyroid gland, etc.) as well as instruments for monitoring the whole body. The standard applies to equipment for the measurement of the activity of gamma-emitting radionuclides in humans in order to determine the committed dose equivalent due to internal contamination in accordance with the recommendations of the ICRP 60 and ICRP 61. The requirements of the standard are applicable to the installed apparatus, to vehiclemounted equipment and to portable instruments. However, Annex B defines the additional mechanical and environmental performance requirements and the additional testing required for transportable and portable assemblies. The general and radiological requirements of all types of in vivo counters are included in this standard. Depending on the type of instrument and the organ to be checked, measurement geometry may require the subject of the monitoring procedure to stand, sit, or lie. The detection assembly includes one or more radiation detector. Normally, these are shielded-scintillation or semi-conductor detectors. Where identification of the location of contamination is required, the detectors may be collimated. The measurement assembly includes functional units for the processing of signals from the detection assembly as well as units for the display of the measured activity. For the measurement of body mass a built-in weighing machine may be used. The standard specifies general types, specific measuring characteristics, main test procedures, electrical and mechanical characteristics Text deleted, as well as the requirements related to background radiation of the environment. This equipment is not intended for the determination of external contamination of the human body or the clothing of personnel. This standard is not applicable to equipment such as radiation detectors intended for introduction into the human body.

Radiation protection instrumentation - In vivo counters - Classification, general requirements and test procedures for portable, transportable and installed equipment

ICS
CCS
F84
发布
2006-06-30
实施
2006-06-30

The scope of this International Standard is to define the performance of installed monitors used for the detection of gamma and neutron radiation emitters contained in objects/ containers or vehicles, general characteristics, mechanical characteristics, environmental requirements, test procedures and documentation. This standard is applicable to installed monitors designed to detect special nuclear and other radioactive materials by their emitted gamma and/or neutron radiation. They are used to monitor vehicles, cargo containers, people, or packages and are typically located at national and international borders, but may be used at any location where there is a need for this type of monitoring. This standard does not apply to hand-held monitors. Information regarding the detection of special nuclear material (SNM) is contained in Annex A. This standard provides the purchaser with information that may be used to determine the performance of the monitor in detecting the presence of radioactive sources. This standard does not provide the data needed to determine the performance of the monitor in measuring the quantity of the radioactive material. In this standard, the term radioactive material includes both special nuclear and radioactive material unless otherwise specifically noted. The radioactive material may be transported by vehicle, carried by person, or concealed in a cargo container or in a package moved by conveyor belt, such as international mail parcels. Conformance with the requirements of this standard does not guarantee that a radioactive source will always be discovered. The selection of the location and the configuration of the monitoring system on each site needs to be optimised to achieve the best performance, however, this is outside the scope of this standard.

Radiation protection instrumentation - Installed radiation monitors for the detection of radioactive and special nuclear materials at national borders

ICS
13.280;17.240
CCS
F84
发布
2006-06
实施
2019-05-09

この規格は,X線及びγ線の1cm線量当量率を測定する放射線サーべイメータ(以下,サーべイメータという。)について規定する。

Portable photon ambient dose equivalent rate meters for use in radiation protection

ICS
17.240
CCS
F84
发布
2006-03-25
实施

この規格は,原子力施設,放射線施設などで使用される,α線放出核種及び最大エネルギー0.15 MeV以上のβ線を放出するβ線放出核種による,手,足及び身体表面の汚染を測定するa線及び/又はβ線用ハンドフットモニタ及び体表面汚染モムタ(以下,モニタという。)について規定する。

Hand and foot monitors and personnel surface contamination monitors for alfha and/or beta emitters

ICS
17.240
CCS
F84
发布
2006-03-25
实施

Radiation Protection Instruments. Supplement 1 Detection Limits and Decision Thresholds for Nuclear Radiation Measurements. Application Direction of ISO 11929 and DIN 25482 Series Standards

ICS
CCS
F84
发布
2006
实施

American National Standard Performance Criteria for Alarming Personal Radiation Detectors for Homeland Security

ICS
17.240
CCS
F84
发布
2006
实施

American National Standard Evaluation and Performance of Radiation Detection Portal Monitors for Use in Homeland Security

ICS
17.240
CCS
F84
发布
2006
实施

American National Standard Performance Criteria for Mobile and Transportable Radiation Monitors Used for Homeland Security

ICS
17.240
CCS
F84
发布
2006
实施

American National Standard Performance Criteria for Alarming Personal Radiation Detectors for Homeland Security

ICS
17.240
CCS
F84
发布
2006
实施

American National Standard for Portable Radiation Detection Instrumentation for Homeland Security

ICS
17.240
CCS
F84
发布
2006
实施

Portable Radiation Detection Instrumentation for Homeland Security

ICS
17.240
CCS
F84
发布
2006
实施

American National Standard Performance Criteria for Hand-held Instruments for the Detection and Indentification of Radionuclides

ICS
17.240
CCS
F84
发布
2006
实施

이 규격은 정상적인 사용 조건에서 유출액이나 지표수 속의 방사능을 연속적으로 감시하기 위한

Radiation protection instrumentation-Equipment for continuously monitoring beta and gamma emitting radionuclides in liquid effluents or in surface waters

ICS
13.280
CCS
F84
发布
2005-06-30
实施
2005-06-30

이 규격은 환경 중 일반적으로 지상 1 m 영역에 불연속되어 있는 방사성 핵종을 현장에서

Radiation protection instrumentation-Measurement of discrete radionuclides in the environment-In situ photon spectrometry system using a germanium detector

ICS
13.280
CCS
F84
发布
2005-06-30
实施
2005-06-30

이 규격은 환경으로 방출되는 기체 유출물 속의 어떤 기체 형태의 삼중수소(tritium)를

Equipment for continuous monitoring of radioactivity in gaseous effluents-Part 5:Specific requirements for tritium monitors

ICS
13.280
CCS
F84
发布
2005-05-31
实施
2005-05-31

이 규격은 모든 형태의 방사성 요오드를 동시, 지연 또는 불연속 순차적(discrete s

Equipment for continuous monitoring of radioactivity in gaseous effluents-Part 4:Specific requirements for radioactive iodine monitors

ICS
13.280
CCS
F84
发布
2005-05-31
实施
2005-05-31

この規格は,光子エネルギー10 keV~3 MeVの照射線量測定器,空気カーマ側定器,空気吸収線量測定器及び線量当量測定器(以下,測定器という。)の校正方法(ただし,特定標準器又は特定ニ次標準器などによる計量法に基づく校正は除く。)について規定する。

Methods of calibration for exposure meters, air kerma meters, air absorbed dose meters and dose-equivalent meters

ICS
17.240
CCS
F84
发布
2005-03-20
实施

Performance criteria are defined, and plutonium radiation is characterized. Thespecifications apply to plutonium handling and storage facilities, excluding reactors and irradiated fuel reprocessing facilities. This standard does not apply to the construc

Performance Criteria for Instrumentation Used for Inplant Plutonium Monitoring

ICS
27.120.20
CCS
F84
发布
2005-03-10
实施

The essential performance parameters and general placement for monitoring the release of radionuclides associated with a postulated serious accident at a reactor facility are defined for various types of instrumentation. The predominant consideration in

Performance Specifications for Reactor Emergency Radiological Monitoring Instrumentation

ICS
27.120.20
CCS
F84
发布
2005-03-10
实施

Equipment for continuous monitoring radioactivity in gaseous effluents - Part 5 : specific requirements for tritium monitors.

ICS
17.240
CCS
F84
发布
2005-03-01
实施
2005-03-05



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号