G62 一般无机试剂 标准查询与下载



共找到 981 条与 一般无机试剂 相关的标准,共 66

本标准规定了化学试剂硝酸铅的技术要求、试验方法、检验规则、包装及标志。

Chemical reagent.Lead nitrate

ICS
71.040.30
CCS
G62
发布
2000-06-05
实施
2001-05-01

本标准规定了化学试剂汞的技术要求、试验方法、检验规则、包装及标志。

Chemical reagent.Mercury

ICS
71.040.30
CCS
G62
发布
2000-06-05
实施
2001-05-01

本标准规定了化学试剂氯化汞的技术要求、试验方法、检验规则、包装及标志。

Chemical reagent.Mercury(Ⅱ)chloride

ICS
71.040.30
CCS
G62
发布
2000-06-05
实施
2001-05-01

本标准规定了化学试剂无水亚硫酸钠的技术要求、试验方法、检验规则、包装及标志。

Chemical reagent.Sodium sulfite anhydrous

ICS
71.040.30
CCS
G62
发布
2000-06-05
实施
2001-05-01

本标准规定了化学试剂铬酸钾的要求、试验方法、检验规则、包装及标志。

Chemical reagent.Potassium Chromate

ICS
71.040.30
CCS
G62
发布
1999-06-16
实施
2000-06-01

本标准规定了化学试剂定氮合金的要求、试验方法、检验规则、包装及标志。

Chemical reagent.Devarda's Alloy

ICS
71.040.30
CCS
G62
发布
1999-06-16
实施
2000-06-01

本标准规定了化学试剂磷酸氢二铵的要求、试验方法、检验规则、包装及标志。

Chemical reagent.Diammonium hydrogen phosphate

ICS
CCS
G62
发布
1999-06-16
实施
2000-06-01

本标准规定了化学试剂磷酸二氢铵的要求、试验方法、检验规则、包装及标志。

Chemical reagent.Ammonium dihydrogen phosphate

ICS
71.040.30
CCS
G62
发布
1999-06-16
实施
2000-06-01

本标准规定了化学试剂草酸铵的技术要求、试验方法、检验规则、包装及标志。

Chemical reagent Diammonium oxalate monohydrate

ICS
71.040.30
CCS
G62
发布
1999-04-20
实施
2000-04-01

本标准规定了化学试剂硫酸钡的技术要求、试验方法、检验规则、包装及标志。

Chemical reagent Barium sulfate

ICS
71.040.30
CCS
G62
发布
1999-04-20
实施
2000-04-01

本标准规定了采用目视比浊法测定磷化溶液中硫酸根含量的方法原理、试剂、分析步骤及分析结果的计算。   本标准适用于磷化溶液中硫酸根含量的测定。测量范围:0.30~0.60g/L

Analytical method of phosphating solution - Determination of sulfate radical content by visual turbidimetry

ICS
71.040.30
CCS
G62
发布
1999-03-12
实施
1999-07-01

It shall be unlawful to interfere with, attempt to interfere with, conspire to interfere with, obstruct or restrict the mobility of or block the path of travel of any fire department emergency vehicle in any way, or to interfere with, attempt to inter

Liquid and Solid Organic Peroxides

ICS
71.040.30
CCS
G62
发布
1999-01-01
实施

The BOCA National Mechanical Code was initially prepared and updated on the premise that adequate code requirements are essential to the safe installation and maintenance of all mechanical equipment and systems in order to protect the public health, sa

Liquid and Solid Oxidizers

ICS
71.040.30
CCS
G62
发布
1999-01-01
实施

1.1 This specification covers requirements for water suitable for use in methods of chemical analysis and physical testing. Four grades are specified: Type IType IIType IIIType IVElectrical conductivity, max, 181S/cm at 298 K (25oC)0.0561.00.255.0Electrical resistivity, min, Mcm at 298 K (25oC)181.0 4.00.2pH at 298 K (25oC)A AA 5.0 to 8.0Total organic carbon (TOC), max, 181g/L5050200no limitSodium, max, 181g/L1510 50Chlorides, max, 181g/L1510 50Total silica, max, 181g/L3 3500no limitMicrobiological contamination-When bacterial levels need to be controlled, reagent grade types should be further classified as follows:Type A Type BType CMaximum heterotrophic bacteria count10/1000 mL10/100 mL100/10 mLEndotoxin, EU/mlB 0.030.25not applicable AThe measurement of pH in Type I, II, and III reagent waters has been eliminated from this specification because these grades of water do not contain constituents in sufficient quantity to significantly alter the pH.B EU = Endotoxin Units.1.2 The method of preparation of the various grades of reagent water determines the limits of impurities and shall be as follows:1.2.1 Type I grade of reagent water shall be prepared by distillation or other equal process, followed by polishing with a mixed bed of ion exchange materials and a 0.2-181m membrane filter. Feedwater to the final polishing step must have a maximum conductivity of 20 181S/cm at 298K (25oC).1.2.2 Type II grade of reagent water shall be prepared by distillation using a still designed to produce a distillate having a conductivity of less than 1.0 181S/cm at 298 K (25oC). Ion exchange, distillation, or reverse osmosis and organic adsorption may be required prior to distillation if the purity cannot be attained by single distillation. Note 18212;Because distillation is a process commonly relied upon to produce high purity water, the levels specified for Type II reagent water were selected to represent the minimum quality of water that a distillation process should produce.1.2.3 Type III grade of reagent water shall be prepared by distillation, ion exchange, continuous electrodeionization reverse osmosis, or a combination thereof, followed by polishing with a 0.45-181m membrane filter.1.2.4 Type IV grade of reagent water may be prepared by distillation, ion exchange, continuous electrodeionization reverse osmosis, electrodialysis, or a combination thereof.1.3 The choice of one of the various grades may be designated by the method or by the investigator.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Reagent Water

ICS
CCS
G62
发布
1999
实施

1.1 This specification covers requirements for water suitable for use in methods of chemical analysis and physical testing. Four grades are specified: Type IType IIType IIIType IVElectrical conductivity, max, 181S/cm at 298 K (25oC)0.0561.00.255.0Electrical resistivity, min, Mcm at 298 K (25oC)181.0 4.00.2pH at 298 K (25oC)A AA 5.0 to 8.0Total organic carbon (TOC), max, 181g/L5050200no limitSodium, max, 181g/L1510 50Chlorides, max, 181g/L1510 50Total silica, max, 181g/L3 3500no limitMicrobiological contamination-When bacterial levels need to be controlled, reagent grade types should be further classified as follows:Type A Type BType CMaximum heterotrophic bacteria count10/1000 mL10/100 mL100/10 mLEndotoxin, EU/mlB 0.030.25not applicable AThe measurement of pH in Type I, II, and III reagent waters has been eliminated from this specification because these grades of water do not contain constituents in sufficient quantity to significantly alter the pH.B EU = Endotoxin Units.1.2 The method of preparation of the various grades of reagent water determines the limits of impurities and shall be as follows:1.2.1 Type I grade of reagent water shall be prepared by distillation or other equal process, followed by polishing with a mixed bed of ion exchange materials and a 0.2-181m membrane filter. Feedwater to the final polishing step must have a maximum conductivity of 20 181S/cm at 298K (25oC).1.2.2 Type II grade of reagent water shall be prepared by distillation using a still designed to produce a distillate having a conductivity of less than 1.0 181S/cm at 298 K (25oC). Ion exchange, distillation, or reverse osmosis and organic adsorption may be required prior to distillation if the purity cannot be attained by single distillation. Note 18212;Because distillation is a process commonly relied upon to produce high purity water, the levels specified for Type II reagent water were selected to represent the minimum quality of water that a distillation process should produce.1.2.3 Type III grade of reagent water shall be prepared by distillation, ion exchange, continuous electrodeionization reverse osmosis, or a combination thereof, followed by polishing with a 0.45-181m membrane filter.1.2.4 Type IV grade of reagent water may be prepared by distillation, ion exchange, continuous electrodeionization reverse osmosis, electrodialysis, or a combination thereof.1.3 The choice of one of the various grades may be designated by the method or by the investigator.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Reagent Water

ICS
71.040.30 (Chemical reagents)
CCS
G62
发布
1999
实施

This commercial item description (CID) covers the requirements for diatomaceous earth which is intended for use in chemical manufacturing as an inert filler and as a filter aid in filtration and purification processes.

DIATOMACEOUS EARTH

ICS
71.040.30
CCS
G62
发布
1998-05-12
实施

Reference materials -- Standard solution -- Ammonium ion

ICS
71.040.30
CCS
G62
发布
1997-09-20
实施

Reference materials -- Standard solution -- Phosphate ion

ICS
71.040.30
CCS
G62
发布
1997-09-20
实施

Reference materials -- Standard solution -- Copper

ICS
71.040.30;71.060.10
CCS
G62
发布
1997-09-20
实施

Chemical reagent Zinc oxide

ICS
71.040.30
CCS
G62
发布
1997-04-21
实施
1998-01-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号