H26 金属无损检验方法 标准查询与下载



共找到 1513 条与 金属无损检验方法 相关的标准,共 101

Non-destructive testing - Ultrasonic testing - Examination for discontinuities perpendicular to the surface

ICS
19.100
CCS
H26
发布
2012-04
实施

Founding - Ultrasonic testing - Part 3: Spheroidal graphite cast iron castings; German version EN 12680-3:2011

ICS
77.040.20
CCS
H26
发布
2012-02-01
实施

Copper and copper alloys - Eddy current test for measuring defects on seamless round copper and copper alloy tubes - Part 2: Test with an internal probe on the inner surface; German version EN 1971-2:2011

ICS
23.040.15;77.150.30
CCS
H26
发布
2012-02
实施

Non-destructive testing - Terminology - Terms used in ultrasonic testing with phased arrays; Trilingual version EN 16018:2011

ICS
01.040.19;19.100
CCS
H26
发布
2012-02
实施

Copper and copper alloys - Eddy current test for measuring defects on seamless round copper and copper alloy tubes - Part 1: Test with an encircling test coil on the outer surface; German version EN 1971-1:2011

ICS
77.150.30
CCS
H26
发布
2012-02
实施

Copper and copper alloys. Eddy current test for measuring defects on seamless round copper and copper alloy tubes. Test with an internal probe on the inner surface

ICS
23.040.15;77.150.30
CCS
H26
发布
2012-01-31
实施
2012-01-31

Copper and copper alloys. Eddy current test for measuring defects on seamless round copper and copper alloy tubes. Test with an encircling test coil on the outer surface

ICS
77.150.30
CCS
H26
发布
2012-01-31
实施
2012-01-31

This Japanese Industrial Standard specifies the classification of leak testing methods commonly used and the guideline for the selection method of adoption thereof. However, this Standard is not intended for the enforcement of practical selection methods.

Non-destructive testing -- Selection of leak testing method

ICS
19.100
CCS
H26
发布
2012-01-20
实施

Non-destructive testing -- Penetrant testing and magnetic particle testing -- Viewing conditions

ICS
19.100
CCS
H26
发布
2012-01-20
实施

Non-destructive testing -- Penetrant testing -- Part 6: Penetrant testing at temperatures lower than 10 degree C

ICS
19.100
CCS
H26
发布
2012-01-20
实施

This Japanese Industrial Standard specifies the method for measurement of the ultrasonic attenuation coefficient of solids at a frequency of 2 MHz or more.

Method for measurement of ultrasonic attenuation coefficient of solids

ICS
19.100
CCS
H26
发布
2012-01-20
实施

Automated eddy current examination of steel pipes and tubes

ICS
23.040.10;77.040.20;77.140.75
CCS
H26
发布
2012-01-20
实施

Non-destructive testing -- Penetrant testing -- Part 5: Penetrant testing at temperatures higher than 50 degree C

ICS
19.100
CCS
H26
发布
2012-01-20
实施

NB/T 47013的本部分规定了承压设备的泄漏检测方法。 本部分适用于在制和在用承压设备的泄漏检测,可以用来确定泄漏部位和测量泄漏率。 本部分规定的各种检测方法与技术要求分别在各附录中规定。

Nondestructive testing of pressure equipments.Part 8:Leak Testing

ICS
77.040.20
CCS
H26
发布
2012-01-04
实施
2012-03-01

NB/T 47013的本部分规定了承压设备的目视检测方法。 本部分适用于在制和在用承压设备的目视检测。对于与承压设备有关的支承件和结构件等的目视检测,也可参照本部分执行。 本部分不适用于其他无损检测方法中的目视观察活动。

Nondestructive testing of pressure equipments. Part 7:Visual examination

ICS
77.040.20
CCS
H26
发布
2012-01-04
实施
2012-03-01

NB/T 47013的本部分规定了金属材料承压设备的声发射检测方法和结果分级与评价。 本部分适用于在制和在用金属承压设备活性缺陷的声发射检测与监测。 本部分不适用于泄漏声发射检测和监测。

Nondestructive testing of pressure equipments.Part 9:Acoustic emission testing

ICS
77.040.20
CCS
H26
发布
2012-01-04
实施
2012-03-01

1.1 This practice covers a basic procedure of ultrasonically inspecting cylindrical forgings with bores from the bore surface. 1.2 This practice applies to the manual testing mode. It does not restrict the use of other testing modes, such as mechanized or automated. 1.3 This practice applies to cylindrical forgings having bore sizes equal to or greater than 2.5 in. [64 mm]. 1.4 This practice is expressed in inch-pound and SI units; however, the inch-pound units shall apply unless the purchase order or contract specifies the applicable 揗?specification designation (SI units). The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Ultrasonic Examination from Bored Surfaces of Cylindrical Forgings

ICS
77.140.85 (Iron and steel forgings)
CCS
H26
发布
2012
实施

1.1 This practice covers straight and angle beam contact, pulse-echo ultrasonic examination of austenitic steel forgings produced in accordance with Practice A388/A388M and Specifications A965/A965M and A1049/A1049M. 1.2 Ultrasonic examination of nonmagnetic retaining ring forgings should be made to Practice A531/A531M rather than this practice. 1.3 Supplementary requirements of an optional nature are provided for use at the option of the purchaser. The supplementary requirements shall apply only when specified individually by the purchaser in the purchase order or contract. 1.4 This practice is expressed in inch-pound and SI units; however, unless the purchase order or contract specifies the applicable “M” specification designation (SI units), the inch-pound units shall apply. The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the practice, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Ultrasonic Examination of Austenitic Steel Forgings

ICS
77.140.85 (Iron and steel forgings)
CCS
H26
发布
2012
实施

1.1 This practice2 covers the standards and procedures for the pulse-echo ultrasonic examination of heat-treated carbon, low-alloy, and martensitic stainless steel castings. 1.2 This practice is to be used whenever the inquiry, contract, order, or specification states that castings are to be subjected to ultrasonic examination in accordance with Practice A609/A609M. 1.3 This practice contains two procedures. Procedure A is the original A609/A609M practice and requires calibration using a series of test blocks containing flat-bottomed holes. It also provides supplementary requirements for angle beam testing. Procedure B requires calibration using a back wall reflection from a series of solid calibration blocks. Note 1: Ultrasonic examination and radiography are not directly comparable. This examination technique is intended to complement Guide E94/E94M in the detection of discontinuities. 1.4 Supplementary requirements of an optional nature are provided for use at the option of the purchaser. The supplementary requirements shall apply only when specified individually by the purchaser in the purchase order or contract. 1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. 1.5.1 Within the text, the SI units are shown in brackets. 1.5.2 This practice is expressed in both inch-pound units and SI units; however, unless the purchase order or contract specifies the applicable M-specification designation (SI units), the inch-pound units shall apply. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Castings, Carbon, Low-Alloy, and Martensitic Stainless Steel, Ultrasonic Examination Thereof

ICS
77.040.20 ; 77.140.80
CCS
H26
发布
2012
实施

1.1 This practice covers the standards and procedures for the pulse-echo ultrasonic examination of heat-treated carbon, low-alloy, and martensitic stainless steel castings. 1.2 This practice is to be used whenever the inquiry, contract, order, or specification states that castings are to be subjected to ultrasonic examination in accordance with Practice A609/A 609M. 1.3 This practice contains two procedures. Procedure A is the original A609/A609M practice and requires calibration using a series of test blocks containing flat bottomed holes. It also provides supplementary requirements for angle beam testing. Procedure B requires calibration using a back wall reflection from a series of solid calibration blocks. Note 18212;Ultrasonic examination and radiography are not directly comparable. This examination technique is intended to complement Guide E94 in the detection of discontinuities. 1.4 Supplementary requirements of an optional nature are provided for use at the option of the purchaser. The supplementary requirements shall apply only when specified individually by the purchaser in the purchase order or contract. 1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.5.1 Within the text, the SI units are shown in brackets. 1.5.2 This practice is expressed in both inch-pound units and SI units; however, unless the purchase order or contract specifies the applicable M specification designation (SI units), the inch-pound units shall apply. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Castings, Carbon, Low-Alloy, and Martensitic Stainless Steel, Ultrasonic Examination Thereof

ICS
77.140.80 (Iron and steel castings)
CCS
H26
发布
2012
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号