K12 带绝缘层电线 标准查询与下载



共找到 1204 条与 带绝缘层电线 相关的标准,共 81

This part of IEC 60317 specifies requirements of glass-fibre wound resin or varnish impregnated@ bare@ grade 1 or grade 2 enamelled round copper winding wire@ temperature index 155. The impregnating agent can be@ for instance@ polyester or polyesterimide resin based. NOTE For this type of wire@ the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently@ a class based on the requirements for temperature index and heat shock temperature cannot be specified.

Specifications for particular types of winding wires - Part 48: Glass-fibre wound resin or varnish impregnated, bare or enamelled round copper wire, temperature index 155

ICS
29.060.10
CCS
K12
发布
2012-07
实施
2012-07-11

Specifications for particular types of winding wires - Part 62: Polyester glass fibre wound, minimum class 200 resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 200

ICS
29.060.10
CCS
K12
发布
2012-07
实施

This part of IEC 60317 specifies the requirements of solderable enamelled round copper winding wire of class 130 with a dual coating. The underlying coating is based on polyurethane resin@ which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is a bonding layer based on a thermoplastic resin. NOTE A modified resin is a resin that has undergone a chemical change@ or contains one or more additives to enhance certain performance or application characteristics. The range of nominal conductor diameters covered by this standard is: ?C Grade 1B: 0@020 mm up to and including 2@000 mm; ?C Grade 2B: 0@020 mm up to and including 2@000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2008.

Specifications for particular types of winding wires - Part 2: Solderable polyurethane enamelled round copper wire, class 130, with a bonding layer

ICS
29.060.10
CCS
K12
发布
2012-07
实施
2012-07-14

Specifications for particular types of winding wires - Part 0-8: General requirements - Polyester glass fibre wound, resin or varnish impregnated or not impregnated, bare or enamelled rectangular copper wire

ICS
29.060.10
CCS
K12
发布
2012-07
实施

This part of IEC 60317 specifies the requirements of glass-fibre wound resin or varnish impregnated@ bare@ grade 1 or grade 2 enamelled round copper winding wire@ temperature index 200. The impregnating agent is silicone resin based. NOTE For this type of wire@ the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently@ a class based on the requirements for temperature index and heat shock temperature cannot be specified.

Specifications for particular types of winding wires - Part 50: Glass-fibre wound silicone resin or varnish impregnated, bare or enamelled round copper wire, temperature index 200

ICS
29.060.10
CCS
K12
发布
2012-07
实施
2012-07-11

This part of IEC 60317 specifies the requirements of polyester glass fibre wound, impregnated or not impregnated, bare or enamelled rectangular copper winding wire, temperature index 155. The range of nominal conductor dimensions covered by this standard is: - width: min. 2,0 mm; max. 16,0 mm; - thickness: min. 0,80 mm; max. 5,60 mm. The specified combinations of width and thickness as well as the specified width/thickness ratio are according to IEC 60317-0-8.

Specifications for particular types of winding wires. Part 60: Polyester glass fibre wound minimum class 155 resin or varnish impregnated or not impregnated, bare or enamelled, rectangular copper wire, temperature index 155

ICS
29.060.10
CCS
K12
发布
2012-06
实施
2012-06

Single- and Multi-Layer Insulated Winding Wire

ICS
29.060.10
CCS
K12
发布
2012-05-14
实施

This part of IEC 60317 specifies the requirements of solderable fully insulated (FIW) zerodefect enamelled round copper wire@ class 180@ with a single coating based on polyurethane resin@ which may be modified providing it retains its chemical identity and satisfies all the required technical specifications. The range of nominal conductor diameters of the wires covered by this standard is as follows: ?C Grade of FIW 3 to FIW 08: 0@040 mm up to and including 0@067 mm; ?C Grade of FIW 3 to FIW 09: 0@071 mm up to and including 0@355 mm; ?C Grade of FIW 3 to FIW 08: 0@375 mm up to and including 0@475 mm; ?C Grade of FIW 3 to FIW 07: 0@500 mm up to and including 0@750 mm; ?C Grade of FIW 3 to FIW 06: 0@800 mm up to and including 1@000 mm; ?C Grade of FIW 3 to FIW 05: 1@060 mm up to and including 1@600 mm. The nominal conductor diameters are specified in IEC 60317-0-7.

Specifications for particular types of winding wires - Part 56: Solderable fully insulated (FIW) zero- defect polyurethane enamelled round copper wire with nominal conductor diameter 0,040 mm to 1,600 mm, class 180

ICS
29.060.10
CCS
K12
发布
2012-05
实施
2017-08-11

This part of IEC 60851 specifies the following tests: ?C Test 9: Heat shock; ?C Test 10: Cut-through; ?C Test 15: Temperature index; ?C Test 21: Loss of mass. For definitions@ general notes on methods of test and the complete series of methods of test for winding wires@ see IEC 60851-1.

Winding wires - Test methods - Part 6: Thermal properties

ICS
29.060.10
CCS
K12
发布
2012-05
实施
2012-05-31

Winding wires - Test methods - Part 5: Electrical properties (IEC 60851-5:2008 + A1:2011); German version EN 60851-5:2008 + A1:2011

ICS
29.060.10
CCS
K12
发布
2012-04-01
实施
2012-04-01

This part of IEC 60317 establishes general requirements for fully insulated (FIW) zero-defect enamelled round copper wires. The nominal conductor diameter range is given in the relevant technical specification.

Specifications for particular types of winding wires - Part 0-7: General requirements - Fully insulated (FIW) zero-defect enamelled round copper wire with nominal conductor diameter of 0,040 mm to 1,600 mm

ICS
29.060.10
CCS
K12
发布
2012-04
实施
2017-08-18

600 V Silicone rubber insulated wires

ICS
29.060.20;77.150.30
CCS
K12
发布
2012-02-20
实施

This standard describes test methods for insulated, single conductor, electric wire intended for aerospace applications. Particular requirements for the wire being tested need to be specified in a procurement document or other detail specification. Suggested minimum requirements are included in the notes at the end of some of the test methods. SAE Performance Standard AS4372 uses some of the tests in this document for evaluating comparative performance of aerospace wires.

Test Methods for Insulated Electric Wire

ICS
49.060
CCS
K12
发布
2012-02-03
实施

本标准规定了漆包铜圆绕组线生产能耗限定值指标、计算原则、计算方法和统计范围。 本标准适用于漆包铜圆绕组线产品电耗的计算、考核,以及新建项目的能耗控制。

Energy consumption index and measurement method for the production of enamelled copper round winding wire

ICS
29.060
CCS
K12
发布
2012-02-01
实施
2012-04-30

Electrical and Electronic FEP (Fluorinated Ethylene Propylene) Insulated High Temperature Hook-Up Wire, Types KT (250 Volt) and KK (1000 Volt)

ICS
29.060.10
CCS
K12
发布
2012-01-01
实施

The methods contained in this standard are intended primarily for referee use, for laboratory measuring, and for certifying size of standard samples used for checking other measuring equipment that may be agreed upon between the supplier and the purchaser.1.1 These test methods cover procedures for measuring the diameter or thickness of round and flat wire (ribbon) 0.060 in. (1.52 mm) maximum used in electronic devices and lamps. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Measuring Diameter or Thickness of Wire and Ribbon for Electronic Devices and Lamps

ICS
29.060.10 (Wires)
CCS
K12
发布
2012
实施

To resolve comments received by UL to the following proposal for UL 2353, which was originally published on June 24, 2011: Publication of the First Edition of the Standard for Single- and Multi-Layer Insulated Winding Wire, UL 2353, as an American National Standard.

Standard for Safety for Single- and Multi-Layer Insulated Winding Wire

ICS
29.060.10
CCS
K12
发布
2012
实施

Packaging of winding wires - Part 4-1: Methods of test - Delivery spools made from thermoplastic materials (IEC 60264-4-1:1997 + A1:2009); German version EN 60264-4-1:2010

ICS
55.060
CCS
K12
发布
2011-11
实施
2011-11-01

ERRATUM

ICS
CCS
K12
发布
2011-10-05
实施

Wire, Electric, Crosslinked Polyalkene Insulated, Silver- Coated High Strength Copper Alloy, Normal Weight, 600-Volt, 150°C

ICS
49.060
CCS
K12
发布
2011-09-06
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved