共找到 1204 条与 带绝缘层电线 相关的标准,共 81 页
Specifications for particular types of winding wires - Part 26: Polyamide-imide enamelled round copper wire, class 200 (IEC 60317-26:1990 + A1:1997 + A2:2010); German version EN 60317-26:1996 + A1:1998 + A2:2010
Specifications for particular types of winding wires - Part 29: Polyester or polyesterimide overcoated with polyamide-imide enamelled rectangular copper wire, class 200 (IEC 60317-29:1990 + A1:1997 + A2:2010); German version EN 60317-29:1996 + A1:1998 + A
This part of IEC 60317 specifies the requirements of enamelled round copper winding wire of class 155 with a sole coating based on polyester resin, which may be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. Class 155 is a thermal class that requires a minimum temperature index of 155 and a heat shock temperature of at least 175 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows: – grade 1:0,020 mm up to and including 3,150 mm; – grade 2:0,020 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1.
Specifications for particular types of winding wires - Part 3: Polyester enamelled round copper wire, class 155
Specifications for particular types of winding wires - Part 13: Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire, class 200 (IEC 60317-13:2010); German version EN 60317-13:2010
Specifications for particular types of winding wires - Part 8: Polyesterimide enamelled round copper wire, class 180 (IEC 60317-8:2010); German version EN 60317-8:2010
Specifications for particular types of winding wires - Part 25: Polyester or polyesterimide overcoated with polyamide-imide enamelled round aluminium wire, class 200 (IEC 60317-25:2010); German version EN 60317-25:2010
Specifications for particular types of winding wires - Part 17: Polyvinyl acetal enamelled rectangular copper wire, class 105 (IEC 60317-17:2010); German version EN 60317-17:2010
Standard for Uninsulated Conductors Used In Electrical and Electronic Applications
Electrical & Electronic PTFE (Polytetrafluoroethylene) Insulated High Temperature Hook-Up Wire; Types ET, (250 Volts), E (600 Volts) and EE (1000 Volts)
Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 3: Guide to use; German version EN 50397-3:2010
Specifications for particular types of winding wires - Part 44: Aromatic polyimide tape wrapped rectangular copper wire, class 240 (IEC 60317-44:1997 + A1:2010); German version EN 60317-44:1997 + A1:2010
Specifications for particular types of winding wires - Part 43: Aromatic polyimide tape wrapped round copper wire, class 240 (IEC 60317-43:1997 + A1:2010); German version EN 60317-43:1997 + A1:2010
Specifications for particular types of winding wires - Part 12: Polyvinyl acetal enamelled round copper wire, class 120 (IEC 60317-12:2010); German version EN 60317-12:2010
1.1 This specification covers shaped wire compact concentric-lay-stranded aluminum conductors, steel supported (ACSS/TW) for use as overhead electrical conductors (see Explanatory Note 1). 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.2.1 Exceptions—For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units are numerically converted from the corresponding requirements in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units. For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard. 1.3 ACSS/TW is designed to increase the aluminum area for a given diameter of conductor by the use of trapezoidal shaped wires (TW), or to reduce the diameter for a given area of aluminum. The conductors consist of a central core of round steel wire(s) surrounded by two or more layers of trapezoidal aluminum 1350-0 wires. Different strandings of the same size of conductor are identified by type, which is the approximate ratio of steel area to aluminum area expressed in percent (see Table 1, Table 2, and Table 3). For the purpose of this specification, the sizes listed in Table 1 and Table 2 are tabulated on the basis of the finished conductor having an area or outside diameter equal to that of specified sizes of standard ACSR, ACSS, and ACSR/TW so as to facilitate conductor selection.TABLE 1 Construction Requirements for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Coated Steel SupportedANote 1—Sized to have area equal aluminum cross-sectional area to an ACSR or ACSS, Class AA conductor. ACSS/TW Conductor Size
Standard Specification for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Supported (ACSS/TW)
Addition of the Aging Condition for the Flexing Test of Nylon Jacketed Types TFN and TFFN
Standard for Safety for Fixture Wire
1.1 This specification covers shaped wire compact concentric-lay-stranded aluminum conductors, steel supported (ACSS/TW) for use as overhead electrical conductors (see Explanatory Note 1). 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.2.1 Exceptions—For conductor sizes designated by AWG or kcmil sizes, the requirements in SI units are numerically converted from the corresponding requirements in inch-pound units. For conductor sizes designated by SI units only, the requirements are stated or derived in SI units. For density, resistivity, and temperature, the values stated in SI units are to be regarded as standard. 1.3 ACSS/TW is designed to increase the aluminum area for a given diameter of conductor by the use of trapezoidal shaped wires (TW), or to reduce the diameter for a given area of aluminum. The conductors consist of a central core of round steel wire(s) surrounded by two or more layers of trapezoidal aluminum 1350-0 wires. Different strandings of the same size of conductor are identified by type, which is the approximate ratio of steel area to aluminum area expressed in percent (see Table 1, Table 2, and Table 3). For the purpose of this specification, the sizes listed in Table 1 and Table 2 are tabulated on the basis of the finished conductor having an area or outside diameter equal to that of specified sizes of standard ACSR, ACSS, and ACSR/TW so as to facilitate conductor selection.TABLE 1 Construction Requirements for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Coated Steel SupportedANote 1—Sized to have area equal aluminum cross-sectional area to an ACSR or ACSS, Class AA conductor. ACSS/TW Conductor Size
Standard Specification for Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Supported (ACSS/TW)
Clarification of Electrical Rating Requirements for Switches
Standard for Safety for Outdoor Seasonal-Use Cord-Connected Wiring Devices
Specifications for particular types of winding wires - Part 15: Polyesterimide enamelled round aluminium wire, class 180 (IEC 60317-15:2004 + A1:2010); German version EN 60317-15:2004 + A1:2010
Specifications for particular types of winding wires - Part 42: Polyester-amide-imide enamelled round copper wire, class 200 (IEC 60317-42:1997 + A1:2010); German version EN 60317-42:1997 + A1:2010
This part of IEC 60317 specifies the requirements of an enamelled round copper winding wire of class 220 with a sole coating based on polyamide-imide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. Class 220 is a thermal class that requires a minimum temperature index of 220 and a heat shock temperature of at least 240 ?C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows: – Grade 1: 0,071 mm up to and including 1,600 mm; – Grade 2: 0,071 mm up to and including 1,600 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1.
Specifications for particular types of winding wires. Polyamide-imide enamelled round copper wire, class 220
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号