K12 带绝缘层电线 标准查询与下载



共找到 1204 条与 带绝缘层电线 相关的标准,共 81

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding wire of class 220 with a sole coating based on polyamide-imide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. Class 220 is a thermal class that requires a minimum temperature index of 220 and a heat shock temperature of at least 240 ?C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor dimensions covered by this standard is as follows: ? width: min. 2,0 mm; max. 16,0 mm; ? thickness: min. 0,80 mm; max. 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2.

Specifications for particular types of winding wires. Polyamide-imide enamelled rectangular copper wire, class 220

ICS
29.060.10
CCS
K12
发布
2010-11-30
实施
2010-11-30

Test procedure for the determination of the temperature index of enamelled winding wires (IEC 60172:1987 + A1:1997 + A2:2010); German version EN 60172:1994 + A1:1998 + A2:2010

ICS
29.060.10
CCS
K12
发布
2010-11
实施
2010-11-01

Specifications for particular types of winding wires - Part 22: Polyester or polyesterimide enamelled round copper wire overcoated with polyamide, class 180 (IEC 60317-22:2004 + A1:2009); German version EN 60317-22:2004 + A1:2010

ICS
29.060.10
CCS
K12
发布
2010-10
实施
2010-10-01

Specifications for particular types of winding wires - Part 18: Polyvinyl acetal enamelled rectangular copper wire, class 120 (IEC 60317-18:2004 + A1:2009); German version EN 60317-18:2004 + A1:2010

ICS
29.060.10
CCS
K12
发布
2010-10
实施
2010-10-01

Winding wires - Test methods - Part 1: General (IEC 60851-1:1996 + A1:2003 + A2:2009); German version EN 60851-1:1996 + A1:2004 + A2:2009

ICS
29.060.10
CCS
K12
发布
2010-09
实施
2010-09-01

Test procedure for the determination of the temperature index of enamelled winding wires.

ICS
29.060.10
CCS
K12
发布
2010-08-01
实施
2010-08-21

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding wire of class 220 with a sole coating based on polyamide-imide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. Class 220 is a thermal class that requires a minimum temperature index of 220 and a heat shock temperature of at least 240 ?C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor dimensions covered by this standard is as follows: ? width: min. 2,0 mm; max. 16,0 mm; ? thickness: min. 0,80 mm; max. 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2.

Specifications for particular types of winding wires - Part 58: Polyamide-imide enamelled rectangular copper wire, class 220

ICS
29.060.10
CCS
K12
发布
2010-08
实施
2010-08-10

Winding wires - Test methods - Part 2: Determination of dimensions (IEC 60851-2:2009); German version EN 60851-2:2009

ICS
29.060.10
CCS
K12
发布
2010-08
实施
2010-08-01

This part of IEC 60317 specifies the requirements of an enamelled round copper winding wire of class 220 with a sole coating based on polyamide-imide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. Class 220 is a thermal class that requires a minimum temperature index of 220 and a heat shock temperature of at least 240 ?C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows: – Grade 1: 0,071 mm up to and including 1,600 mm; – Grade 2: 0,071 mm up to and including 1,600 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1.

Specifications for particular types of winding wires - Part 57: Polyamide-imide enamelled round copper wire, class 220

ICS
29.060.10
CCS
K12
发布
2010-08
实施

Specification for particular types of winding wires - Part 43: Aromatic polyimide tape wrapped round copper wire, class 240

ICS
29.060.10
CCS
K12
发布
2010-07-01
实施

Specifications for particular types of winding wires - Part 42: Polyester-amide-imide enamelled round copper wire, class 200

ICS
29.060.10
CCS
K12
发布
2010-07-01
实施

Specifications for particular types of winding wires - Part 44: Aromatic polyimide tape wrapped rectangular copper wire, class 240

ICS
29.060.10
CCS
K12
发布
2010-07-01
实施

This Part of IEC 60317 specifies the requirements of enamelled round copper winding wires of class 180 with a sole coating based on polyesterimide resin, which may be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements. Class 180 is a thermal class that requires a minimum temperature index of 180 and a heat shock temperature of at least 200 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows: – Grade 1: 0,018 mm up to and including 3,150 mm; – Grade 2: 0,020 mm up to and including 5,000 mm; – Grade 3: 0,250 mm up to and including 1,600 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1.

Specifications for particular types of winding wires - Polyesterimide enamelled round copper wire, class 180

ICS
29.060.10
CCS
K12
发布
2010-06-30
实施
2010-06-30

This Part of IEC 60317 specifies the requirements of enamelled round copper winding wire of class 200 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamideimide resin. Class 200 is a thermal class that requires a minimum temperature index of 200 and a heat shock temperature of at least 220 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of a nominal conductor diameters covered by this standard is as follows: – Grade 1: 0,050 mm up to and including 2,000 mm; – Grade 2: 0,050 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1.

Specifications for particular types of winding wires - Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire, class 200

ICS
29.060.10
CCS
K12
发布
2010-06-30
实施
2010-06-30

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding wire of class 105 with a sole coating based on polyvinyl acetal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. Class 105 is a thermal class that requires a minimum temperature index of 105 and a heat shock temperature of at least 155 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor dimensions covered by this standard is – width: min. 2,00 mm max. 16,00 mm; – thickness: min. 0,80 mm max. 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2.

Specifications for particular types of winding wires - Polyvinyl acetal enamelled rectangular copper wire, class 105

ICS
29.060.10
CCS
K12
发布
2010-06-30
实施
2010-06-30

This Part of IEC 60317 specifies the requirements of enamelled round aluminium winding wires of class 200 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin. Class 200 is a thermal class that requires a minimum temperature index of 200 and a heat shock temperature of at least 220 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows: – Grade 1: 0,400 mm up to and including 3,150 mm; – Grade 2: 0,400 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3.

Specifications for particular types of winding wires - Polyester or polyesterimide overcoated with polyamide-imide enamelled round aluminium wire, class 200

ICS
29.060.10
CCS
K12
发布
2010-06-30
实施
2010-06-30

This part of IEC 60317 specifies the requirements of enamelled round aluminium winding wire of class 180 with a sole coating based on polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. Class 180 is a thermal class that requires a minimum temperature index of 180 and a heat shock temperature of at least 200 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows: – grade 1: 0,400 mm up to and including 1,600 mm; – grade 2: 0,400 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3.

Specifications for particular types of winding wires - Part 15: Polyesterimide enamelled round aluminium wire, class 180

ICS
29.060.10
CCS
K12
发布
2010-06-01
实施

This Part of IEC 60317 specifies the requirements of enamelled round copper winding wire of class 120 with a sole coating based on polyvinyl acetal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. Class 120 is a thermal class that requires a minimum temperature index of 120 and a heat shock temperature of at least 155 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is: – Grade 1: 0,040 mm up to and including 2,500 mm; – Grade 2: 0,040 mm up to and including 5,000 mm; – Grade 3: 0,080 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1.

Specifications for particular types of winding wires - Polyvinyl acetal enamelled round copper wire, class 120

ICS
29.060.10
CCS
K12
发布
2010-05-31
实施
2010-05-31

This Part 2 of EN 50397 contains the requirements for accessories that are for use with the covered conductors in accordance with EN 50397-1. They are for applications in overhead lines with rated voltages U above 1 kV a.c. and not exceeding 36 kV a.c. This European Standard describes the requirements and tests only for the accessories installed on the covered conductor itself.

Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2: Accessories for covered conductors - Tests and acceptance criteria; German version EN 50397-2:2009

ICS
29.240.20
CCS
K12
发布
2010-05
实施
2010-05-01

本标准规定了200级耐电晕漆包铜圆线的分类、技术要求、检验方法、检验规则及包装。 本标准适用于热级为200级的耐电晕漆包铜圆线。

Corona-resistant enamelled copper wires,class 200

ICS
29.060.10
CCS
K12
发布
2010-04-22
实施
2010-10-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号