K12 带绝缘层电线 标准查询与下载



共找到 1204 条与 带绝缘层电线 相关的标准,共 81

Specifications for particular types of winding wires - Part 0-3 : general requirements - Enamelled round aluminium wire.

ICS
29.060.10
CCS
K12
发布
2005-03-01
实施
2005-03-20

This is Amendment 2 IEC 60317-17-1990 (Specifications for particular types of winding wires -Part 17:Polyvinyl acetal enamelled rectangular copper wire, class 105)

Amendment 2 - Specifications for particular types of winding wires - Part 17: Polyvinyl acetal enamelled rectangular copper wire, class 105

ICS
29.060.10
CCS
K12
发布
2005-03
实施
2010-03-12

This is Amendment 2 IEC 60317-0-2-1997 (Specifications for particular types of winding wires -Part 0-2:General requirements -Enamelled rectangular copper wire)

Specifications for particular types of winding wires - Part 0-2: General requirements - Enamelled rectangular copper wire; Amendment 2

ICS
29.060.10
CCS
K12
发布
2005-01
实施

Individual varnishes behave differently when applied to the same fibrous- or film-wrapped magnet wire when exposed to elevated temperatures. Likewise, a varnish does not always behave the same when applied to different types of fibrous or film-wrapped magnet wires and when exposed to elevated temperatures. FIG. 1 Jig for Forming Wire1.1 This test method covers the determination of thermal endurance of rectangular and square fibrous- or film-wrapped magnet wire coated with an insulating varnish.1.2 The values given in SI units are the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific precautionary statement is given in Section 5.Note 18212;There is no similar or equivalent IEC Standard.

Standard Test Method for Thermal Endurance of Varnished Fibrous- or Film-Wrapped Magnet Wire

ICS
29.060.10 (Wires)
CCS
K12
发布
2005
实施

GB/T 11018的本部分规定了130级丝包直焊聚氨酯漆包束线的要求。 丝包层由一层或两层丝组成。 单根漆包线为130级直焊聚氨酯漆包铜圆线(GB/T 6109.4)。 当提及GB/T 11018的本部分所涉及的产品时,给出如下内容: ——GB编号和(或)IEC编号; 一一束丝中的单线根数和导体标称直径,mm。 示例:GB/T l1018.2—2008 O.071×25或IEC 60317—11—25×O.071

Specifications for particular types of winding wires-Part11:Bunched solderable polyurethane enamelled round copper wires ,class130,with silk covering

ICS
29.060.10
CCS
K12
发布
2005
实施

Individual varnishes behave differently when applied to the same fibrous- or film-wrapped magnet wire when exposed to elevated temperatures. Likewise, a varnish does not always behave the same when applied to different types of fibrous or film-wrapped magnet wires and when exposed to elevated temperatures. FIG. 1 Jig for Forming Wire1.1 This test method covers the determination of thermal endurance of rectangular and square fibrous- or film-wrapped magnet wire coated with an insulating varnish. 1.2 The values given in SI units are the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific precautionary statement is given in Section 5. Note 18212;There is no similar or equivalent IEC Standard.

Standard Test Method for Thermal Endurance of Varnished Fibrous- or Film-Wrapped Magnet Wire

ICS
29.060.10 (Wires)
CCS
K12
发布
2005
实施

GB/T 4074的本部分规定了下列试验方法: ——试验方法12:耐溶剂; ——试验方法16:耐冷冻剂; ——试验方法17:直焊性; 一一试验方法20:耐水解和耐变压器油。 定义、试验方法总则和绕组线试验方法一览表见GB/T 4074.1。

Winding wires-Test methods-Part4:Chemical properties

ICS
29.060.01
CCS
K12
发布
2005
实施

1.1 This specification covers 8000 series aluminum alloys fabricated into round wires in annealed or intermediate tempers suitable for stranding into conductors or for solid single conductors, usually to be insulated.1.2 The values stated in inch-pound or SI units are to be regarded separately as the standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.2.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as the standard.Note 1Aluminum alloys capable of meeting the requirements of this specification are listed in .Note 2The alloy and temper designations conform to ANSI H35.1. Unified Numbering System alloy designations are listed in in accordance with Practice E 527.Note 3Certain aluminum alloys may be subject to patent rights. U.S. patents numbers are shown in .This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for 8000 Series Aluminum Alloy Wire for Electrical Purposes-Annealed and Intermediate Tempers

ICS
29.060.10 (Wires)
CCS
K12
发布
2005
实施

1.1 This specification covers tinned hard-drawn and medium-hard-drawn round copper wire for electrical purposes.1.2 The SI values of resistance and density are to be regarded as standard. For all other properties, values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information purposes only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For hazard statement, see Sections and .

Standard Specification for Tinned Hard-Drawn and Medium-Hard-Drawn Copper Wire for Electrical Purposes

ICS
29.060.10 (Wires)
CCS
K12
发布
2005
实施

Substantive revisions to the proposed Sixth edition of UL 1088 are being recirculated for review and comment, which include (a) the deletion of use of cadmium coating for corrosion protection, (b) correction to the designations of outdoor cords from "W-A" to "W", and (c) the addition of an Exception to the Security of Screw Shell Test if a lampholder complies with UL 496.

Standard for Safety for Temporary Lighting Strings

ICS
29.140.40
CCS
K12
发布
2005
实施

Substantive changes to the following proposals of the UL 817 bulletin dated July 20, 2004: 1. Revision to Requirements to Reference ANSI/NEMA WD 6 Instead of UL 1681 2. Clarification of Outdoor-Use Cord Set and Noninterchangeability Requirements 8. Clarification of Requirements for Special-Use Power-Supply Cords 9. Clarification of Requirements for Switches Used in Cord Sets.

Standard for Safety for Cord Sets and Power-Supply Cords (Bulletin dated 3/14/2005)

ICS
29.060.20
CCS
K12
发布
2005
实施

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding wire of class 120 with a sole coating based on polyvinyl acetal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. Class 120 is a thermal class that requires a minimum temperature index of 120 and a heat shock temperature of at least 155 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor dimensions covered by this standard is as follows: ? width: minimum 2,0 mm; maximum 16,0 mm; ? thickness: minimum 0,80 mm; maximum 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio width/ thickness are given in IEC 60317-0-2.

Specifications for particular types of winding wires - Polyvinyl acetal enamelled rectangular copper wire, class 120

ICS
29.060.10
CCS
K12
发布
2004-12-13
实施
2004-12-13

This part of IEC 60317 specifies the requirements of enamelled round copper winding wire of class 180 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide resin. Class 180 is a thermal class that requires a minimum temperature index of 180 and a heat shock temperature of at least 200 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows: – grade 1: 0,050 mm up to and including 3,150 mm; – grade 2: 0,050 mm up to and including 5,000 mm; – grade 3: 0,250 mm up to and including 1,600 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1.

Specifications for particular types of winding wires - Polyester or polyesterimide enamelled round copper wire overcoated with polyamide, class 180

ICS
29.060.10
CCS
K12
发布
2004-12-13
实施
2004-12-13

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding wire of class 120 with a sole coating based on polyvinyl acetal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. Class 120 is a thermal class that requires a minimum temperature index of 120 and a heat shock temperature of at least 155 ℃. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor dimensions covered by this standard is as follows: - width: minimum 2,0 mm; maximum 16,0 mm; - thickness: minimum 0,80 mm; maximum 5,60 mm. Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio width/ thickness are given in IEC 60317-0-2.

Specifications for particular types of winding wires - Polyvinyl acetal enamelled rectangular copper wire, class 120

ICS
29.060.10
CCS
K12
发布
2004-12-13
实施
2004-12-13

This part of IEC 60317 specifies the requirements of enamelled round copper winding wire of class 180 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide resin. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. Class 180 is a thermal class that requires a minimum temperature index of 180 and a heat shock temperature of at least 200 ℃. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows: - grade 1: 0,050 mm up to and including 3,150 mm; - grade 2: 0,050 mm up to and including 5,000 mm; - grade 3: 0,250 mm up to and including 1,600 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1.

Specifications for particular types of winding wires - Polyester or polyesterimide enamelled round copper wire overcoated with polyamide, class 180

ICS
29.060.10
CCS
K12
发布
2004-12-13
实施
2004-12-13

Insulated cables and their accessories for power systems - Suspension equipments for overhead distribution with bundle assembled cores, of rated voltage 0,6/1 kV.

ICS
29.240.20
CCS
K12
发布
2004-12-01
实施
2004-12-20

This part of IEC 60317 specifies the requirements of enamelled round aluminium winding wire of class 180 with a sole coating based on polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. Class 180 is a thermal class that requires a minimum temperature index of 180 and a heat shock temperature of at least 200 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows: – grade 1: 0,400 mm up to and including 1,600 mm; – grade 2: 0,400 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3.

Specifications for particular types of winding wires - Polyesterimide enamelled round aluminium wire, class 180

ICS
29.060.10
CCS
K12
发布
2004-11-25
实施
2004-11-25

This part of IEC 60317 specifies the requirements of enamelled round aluminium winding wire of class 180 with a sole coating based on polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. Class 180 is a thermal class that requires a minimum temperature index of 180 and a heat shock temperature of at least 200 ℃. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows: - grade 1: 0,400 mm up to and including 1,600 mm; - grade 2: 0,400 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3.

Specifications for particular types of winding wires - Polyesterimide enamelled round aluminium wire, class 180

ICS
29.060.10
CCS
K12
发布
2004-11-25
实施
2004-11-25

KS C IEC 60317-37은 이중 코팅을 가지고 분류 등급 180인 납땜 가능한

Specifications for particular types of winding wires-Part 37:Polyesterimide enamelled round copper wire, class 180, with a bonding layer

ICS
29.060.10
CCS
K12
发布
2004-11-20
实施
2004-11-20

KS C IEC 60317-42는 폴리에스터-아미드-이미드 수지를 기본으로 단일 코팅한

Specifications for particular types of winding wires-Part 42:Polyester-amide-imide enamelled round copper wire, class 200

ICS
29.060.10
CCS
K12
发布
2004-11-20
实施
2004-11-20



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved