K20 旋转电机综合 标准查询与下载



共找到 1061 条与 旋转电机综合 相关的标准,共 71

This part of IEC 60034 relates to a.c. machines incorporating form-wound stator coils. It specifies the test procedures and voltages to be applied to the main and interturn insulation of sample coils.

Rotating electrical machines - Impulse voltage withstand levels of form-wound stator coils for rotating a.c. machines

ICS
29.160.01
CCS
K20
发布
2009-10-31
实施
2009-10-31

Defines criteria for assessing the insulation system of stator/rotor windings of single or polyphase AC machines which are subjected to repetitive impulse voltages, such as pulse width modulation (PWM) converters, and expected to withstand partial discha

Rotating electrical machines Part 18-42: Qualification and acceptance tests for partial discharge resistant electrical insulation systems (Type II) used in rotating electrical machines fed from voltage converters

ICS
29.080.30;29.160;29.160.01
CCS
K20
发布
2009-10-02
实施

This part of IEC 60034 establishes the principal characteristics of a.c. generators under the control of their voltage regulators when used for reciprocating internal combustion (RIC) engine driven generating set applications and supplements the requirements given in IEC 60034-1. It covers the use of such generators for land and marine use@ but excludes generating sets used on aircraft or used to propel land vehicles and locomotives. NOTE 1 For some specific applications (e.g. essential hospital supplies@ high-rise buildings@ etc.) supplementary requirements may be necessary. The provisions of this standard should be regarded as a basis for such requirements. NOTE 2 Attention is drawn to the need to take note of additional regulations or requirements imposed by various regulatory bodies. Such regulations or requirements may form the subject of agreement between the customer and the manufacturer when conditions of use of the end product invoke such requirements. NOTE 3 Examples of regulatory authorities: ? classification societies@ for generating sets used on ships and offshore installations; ? government agencies; ? inspection agencies@ local utilities@ etc. Annex A discusses the behaviour of generators covered by this standard when subjected to sudden load changes.

Rotating electrical machines - Part 22: AC generators for reciprocating internal combustion (RIC) engine driven generating sets

ICS
29.160.20
CCS
K20
发布
2009-10
实施
2009-10-30

Defines criteria for assessing the insulation system of stator/rotor windings which are subjected to pulse width modulation (PWM) drives. Applies to stator/rotor windings of single or polyphase AC machines with insulation systems for converter operation.

Rotating electrical machines Part 18-41: Qualification and type tests for Type I electrical insulation systems used in rotating electrical machines fed from voltage converters

ICS
29.160
CCS
K20
发布
2009-09-04
实施

Rotating electrical machines - Part 24: Online detection and diagnosis of potential failures at the active parts of rotating electrical machines and of bearing currents - Application guide

ICS
29.160.01
CCS
K20
发布
2009-09
实施

Rotating electrical machines - Part 15 : impulse voltage withstand levels of form-wound stator coils for rotating a.c. machines.

ICS
29.160.01
CCS
K20
发布
2009-08-01
实施
2009-08-01

Rotating electrical machines - Part 25: Guidance for the design and performance of a.c. motors specifically designed for converter supply (IEC/TS 60034-25:2007); German version CLC/TS 60034-25:2008

ICS
29.160.30
CCS
K20
发布
2009-08
实施
2009-08-01

本标准针对重覆冰线路特点,规定了线路路径选择、导地线选择和布置、杆塔型式、杆塔荷载及交叉跨越等的技术要求。 本标准适用于 110kV-750kV 重覆冰架空输电线路设计,其他电压等级的交直流重覆冰架空输电线路设计可参照执行。

Technical code for designing of overhead transmission line in medium & heavy icing area

ICS
29.240.20
CCS
K20
发布
2009-07-22
实施
2009-12-01

This part of IEC 60034 specifies efficiency classes for single-speed, three-phase, 50 Hz and 60 Hz, cage-induction motors that: • have a rated voltage UN up to 1 000 V; NOTE The standard also applies to motors rated for two or more voltages and/or frequencies. • have a rated output PN between 0,75 kW and 375 kW; • have either 2, 4 or 6 poles; • are rated on the basis of either duty type S1 (continuous duty) or S3 (intermittent periodic duty) with a rated cyclic duration factor of 80 % or higher; • are capable of operating direct on-line; • are rated for operating conditions in accordance with IEC 60034-1, Clause 6. Motors with flanges, feet and/or shafts with mechanical dimensions different from IEC 60072-1 are covered by this standard. Geared motors and brake motors are covered by this standard although special shafts and flanges may be used in such motors. Excluded are: • Motors made solely for converter operation in accordance with IEC 60034-25. • Motors completely integrated into a machine (for example pump, fan and compressor) that cannot be tested separately from the machine.

Rotating electrical machines - Efficiency classes of single-speed, three-phase, cage-induction motors (IE-code)

ICS
29.160.30
CCS
K20
发布
2009-06-30
实施
2009-06-30

Specifies efficiency classes for single-speed, three-phase, 50 Hz and 60 Hz, cage-induction motors. Covers motors with flanges, feet and/or shafts with mechanical dimensions different from IEC 60072-1. Does not cover motors made solely for convertor oper

Rotating electrical machines Part 30: Efficiency classes of single-speed, three-phase, cage-induction motors (IE-code)

ICS
29.160.30
CCS
K20
发布
2009-06-26
实施

Rotating electrical machines - Part 30 : efficiency classes of single-speed, three-phase, cage-induction motors (IE-code).

ICS
29.160.30
CCS
K20
发布
2009-05-01
实施
2009-05-15

IEC 61800-7 specifies profiles for Power Drive Systems (PDS) and their mapping to existing communication systems by use of a generic interface model. The functions specified in this part of IEC 61800-7 are not intended to ensure functional safety. This requires additional measures according to the relevant standards, agreements and laws. This part of IEC 61800-7 specifies profile type 4 for Power Drive Systems (PDS). Profile type 4 can be mapped onto different communication network technologies.

Adjustable speed electrical power drive systems - Generic interface and use of profiles for power drive Systems - Profile type 4 specification

ICS
29.160.30;29.200
CCS
K20
发布
2009-04-30
实施
2009-04-30

This part of IEC 60034 describes the design features and performance characteristics of a.c. motors specifically designed for use on converter supplies. It also specifies the interface parameters and interactions between the motor and the converter including installation guidance as part of a power drive system. The general requirements of relevant parts of the IEC 60034 series of standards also apply to motors within the scope of this technical specification. NOTE 1 For motors operating in potentially explosive atmospheres, additional requirements as described in the IEC 60079 series apply. NOTE 2 This technical specification is not primarily concerned with safety. However, some of its recommendations may have implications for safety, which should be considered as necessary. NOTE 3 Where a converter manufacturer provides specific installation recommendations, they should take precedence over the recommendations of this technical specification.

Rotating electrical machines - Guidance for the design and performance of a.c. motors specifically designed for converter supply

ICS
29.160.30
CCS
K20
发布
2009-03-31
实施
2009-03-31

This part of IEC 60034 applies to three-phase synchronous machines of 1 kVA rating and larger with rated frequency of not greater than 500 Hz and not less than 10 Hz. Most of the methods are intended to be used for machines having an excitation winding with slip-rings and brushes for their supply. Synchronous machines with brushless excitation require special effort for some of the tests. For machines with permanent magnet excitation, there is a limited applicability of the described tests, and special precautions have to be taken against irreversible demagnetization. Excluded are axial-field machines and special synchronous machines such as inductor type machines and transversal flux machines. It is not intended that this standard be interpreted as requiring any or all of the tests described therein on any given machine. The particular tests to be carried out shall be subject to agreement between manufacturer and customer.

Rotating electrical machines - Methods for determining synchronous machine quantities from tests

ICS
29.160.01
CCS
K20
发布
2009-03-31
实施
2009-03-31

Portable engine-generator assemblies

ICS
27.020;29.160.40
CCS
K20
发布
2009-03-04
实施

This part of IEC 34 specifies the rated phase-to-earth impulse voltage withstand levels of rotating a.c. machines having rated voltages from 3 kV to 15 kV inclusive and incorporating form-wound stator coils@ together with the test procedures and voltages to be applied to the main and interturn insulation of sample coils to prove the compliance of the machine.

Rotating electrical machines - Part 15: Impulse voltage withstand levels of form-wound stator coils for rotating a.c. machines

ICS
29.160.01
CCS
K20
发布
2009-03
实施
2009-03-19

The scope of this SAE Recommended Practice is to provide a uniform practice for the testing of small engine powered alternating current generator sets. This document is limited to reciprocating piston engines of less than 14.9 kw (20 BHP).

Procedure for Evaluating Transient Response of Small Engine Driven Generator Sets

ICS
29.160.20
CCS
K20
发布
2009-01-26
实施

Rotating electrical machines - Part 29: Equivalent loading and superposition techniques - Indirect testing to determine temperature rise (IEC 60034-29:2008); German version EN 60034-29:2008

ICS
29.160.01
CCS
K20
发布
2009-01
实施
2009-01-01

This document describes very low frequency (VLF) testing of ac electric machines. It covers acceptance testing of new machines in the factory or on-site after erection. Also covered is the routine maintenance testing of machines that have been in service. In order to facilitate communication and comparison among investigators, this document recommends that the very low frequency used be 0.1 Hz +/- 10 percent.

Recommended Practice for Insulation Testing of AC Electric Machinery with High Voltage at Very Low Frequency

ICS
29.080.01;29.160.01
CCS
K20
发布
2009
实施

Recommended Practice for Insulation Testing of AC Electric Machinery with High Voltage at Very Low Frequency

ICS
29.080.01
CCS
K20
发布
2009
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved