K30 低压电器综合 标准查询与下载



共找到 1074 条与 低压电器综合 相关的标准,共 72

Applicable to low-voltage switchgear and controlgear ASSEMBLIES that are type tested, that have stated deviations and a rated short-circuit withstand strength above 10 kA, are stationary or movable, that have a rated voltage not exceeding 1 000 V a.c. at

Low-voltage switchgear and controlgear ASSEMBLIES Part 1: Type-tested ASSEMBLIES with stated deviations and a rated short-circuit withstand strength above 10 kA

ICS
29.130.20
CCS
K30
发布
2007-12-14
实施

Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 1 : general rules.

ICS
29.130.20
CCS
K30
发布
2007-12-01
实施
2007-12-07

This PAS describes circular M12-connectors typically used for industrial process measurement and control. These connectors consist of fixed and free connectors with screwlocking as well as adaptors. The connectors are suitable to connect two optic fibres and two electrical wires intended for power transmission to the optionally integrated transmitter and receiver, not specified in this PAS. Male connectors have round electrical contacts ? 1,0 mm and cylindrical ceramic optic contacts ? 1,25 mm according to IEC 61754-20 Type LC for All-silica optic fibre cables Single-Mode fibre 9/125 ?m Multi-Mode fibre 50/125 ?m or 62,5/125 ?m NOTE M12 is the dimension of the thread of the screw locking mechanism of these circular connectors.

Connectors for electric equipment - Product requirements - Part 2-107: Circular connectors - Detail specification for circular hybrid connectors M12 with electrical and fibre-optic contacts with screw-locking

ICS
31.220.10;33.180.20
CCS
K30
发布
2007-12
实施

Low-voltage switchgear and controlgear - Part 6-2: Multiple function equipment - Control and protective switching devices (or equipment) (CPS) (IEC 60947-6-2:2002 + A1:2007); German version EN 60947-6-2:2003 + A1:2007

ICS
29.130.20
CCS
K30
发布
2007-12
实施
2007-12-01

This part of IEC 60947 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field. These proximity switches are self-contained, have semiconductor switching elements(s) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz a.c. or 300 V d.c. This Standard is not intended to cover proximity switches with analogue outputs. The object of this standard is to state for proximity switches: – definitions; – classification; – characteristics; – product information; – normal service, mounting and transport conditions; – constructional and performance requirements; – tests to verify rated characteristics.

Low-voltage switchgear and controlgear — Part 5-2: Control circuit devices and switching elements — Proximity switches

ICS
29.120.40;29.130.20
CCS
K30
发布
2007-12
实施

이 규격에서는 50~60 Hz의 교류와 직류 전원 회로, 그리고 1 000 V r.m.s

Low-voltage surge protective devices-Part 12:Surge protective devices connected to low-voltage power distribution systems-Selection and application principles

ICS
29.240.10;29.240
CCS
K30
发布
2007-11-30
实施
2007-11-30

Covers the rating and dimensions of the conventional 16 A 250 V a.c. plug and socket-outlet system and socket-outlet adaptors for household and similar purposes, for use in South Africa.

Plug and socket-outlet systems for household and similar purposes for use in South Africa Part 1: Conventional system, 16 A 250 V a.c.

ICS
29.120.30
CCS
K30
发布
2007-11-30
实施
2007-11-30

Covers the rating and dimensions of the conventional 6 A 250 V a.c. plug and socket-outlet system and socket-outlet adaptors for household and similar purposes, for use in South Africa.

Plug and socket-outlet systems for household and similar purposes for use in South Africa Part 3: Conventional system, 6 A 250 V a.c.

ICS
29.120.30
CCS
K30
发布
2007-11-30
实施
2007-11-30

Covers the rating and dimensions of the 16 A dedicated plug and socket-outlet system for the connection of equipment to a dedicated supply system, having a nominal voltage of 250 V a.c. in household and similar applications in South Africa.

Plug and socket-outlet systems for household and similar purposes for use in South Africa Part 4: Dedicated system, 16 A 250 V a.c.

ICS
29.120.30
CCS
K30
发布
2007-11-30
实施
2007-11-30

Covers the rating and dimensions of two-pole, non-rewirable plugs, rated at 2,5 A 250 V a.c., for connection of class 11 equipment for household and similar purposes, for use in South Africa.

Plug and socket-outlet systems for household and similar purposes for use in South Africa Part 5: Two-pole, non-rewirable plugs, 2,5 A 250 V a.c., with cord, for connection of class II equipment

ICS
29.120.30
CCS
K30
发布
2007-11-30
实施

Applies to flow rate switches that sense the rate of flow of a gas, a liquid or a granular solid. These switches change their output state if a pre-set value for the speed of flow is exceeded.

Low-voltage switchgear and controlgear Part 5-9: Control circuit devices and switching elements - Flow rate switches

ICS
29.130.20
CCS
K30
发布
2007-11-02
实施

Gives supplementary requirements for enclosed distribution boards (DBU) that are stationary, type-tested assemblies (TTA) for indoor use, containing protective devices and intended for use either in domestic (household) applications or in other places wh

Low-voltage switchgear and controlgear assemblies Part 3: Particular requirements for low-voltage switchgear and controlgear assemblies intended to be installed in places where unskilled persons have access for their use - Distribution boards

ICS
29.130.20
CCS
K30
发布
2007-11-02
实施

Describes a method for specifying requirements for low-voltage power supply devices (including switching types) providing d.c. output(s) up to 200 V d.c. at a power level of up to 30 kW, operating from a.c. or d.c. source voltages of up to 600 V.

Low-voltage power supply devices, d.c. output - Performance characteristics

ICS
29.160.40
CCS
K30
发布
2007-11-02
实施

Applies to portable devices for household and similar uses (PRCDs), consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection, functionally independent of, or functionally dependent on, line voltage. They do not incorporate overcurrent protection. They are intended for single-phase circuits for rated currents not exceeding 16 A for rated voltages not exceeding 250 V a.c., or for rated current not exceeding 32 A for rated voltages not exceeding 130 V a.c. to earth. They are intended to provide protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream.

Electrical accessories - Portable residual current devices without integral overcurrent protection for household and similar use (PRCDs)

ICS
29.120.50
CCS
K30
发布
2007-11-02
实施

This Part 2-4 of IEC 60884 applies to plugs, fixed or portable socket-outlets, and to socketoutlets for appliances from 6 V up to and including 48 V d.c. or a.c. (50/60 Hz) SELV with rated current of 16 A, intended for household and similar purposes, either indoors or outdoors. NOTE 1 The extension of this standard to higher frequencies is under consideration. This standard does not cover requirements for flush mounting boxes; it covers only those requirements for surface-type mounting boxes which are necessary for the tests on the socketoutlet. This standard also applies to plugs and socket-outlets incorporated in cord extension sets or integrated in or incorporated in appliances or intended to be fixed to them. NOTE 2 A socket-outlet integrated in an appliance or equipment is a socket-outlet which is formed by the housing of the appliance or equipment. A socket-outlet incorporated in an appliance or equipment is a separate socket-outlet built in or fixed to an appliance or equipment. In addition, socket-outlets for appliances or equipment must comply with IEC 60884-2-2. This standard does not apply to – plugs, socket-outlets and couplers for industrial purposes; – appliance couplers; – fixed socket-outlets combined with fuses, automatic switches, etc. Plugs and fixed or portable socket-outlets complying with this standard are suitable for use at ambient temperatures not normally exceeding 25 °C, but occasionally reaching 35 °C. NOTE 3 Socket-outlets complying with this standard are only suitable for incorporation in equipment in such a way and in such a place that it is unlikely that the surrounding temperature exceeds 35 °C. In locations where special conditions prevail, such as in ships, vehicles and the like, and in hazardous locations, for example where explosions are liable to occur, special constructions may be required.

Plugs and socket-outlets for household and similar purposes - Part 2-4: Particular requirements for plugs and socket-outlets for SELV

ICS
29.120.30
CCS
K30
发布
2007-11
实施
2007-11-23

The IEC 61915 series is intended to improve interoperability of devices, network tools and application software. This part of IEC 61915 defines a framework for common representation of networked industrial devices and provides a template for documenting such a representation, independent of the network used. This framework follows the principles given in IEC/TR 62390, the “Common automation device – Profile guideline”, and refers to ISO 15745, “Industrial automation systems and integration – Open systems application integration framework”. NOTE 1 The device profile format specified in this part of IEC 61915 is compatible with devices connected to both bit- and byte-oriented networks. This part of IEC 61915 applies to root device profiles, generic device profiles, and specific device profiles. The root device profiles will be published in subsequent parts of the IEC 61915 series. NOTE 2 This International Standard is specifically intended for products covered by the IEC 60947 series. NOTE 3 Organisations such as consortia are encouraged to use the rules defined in this part of IEC 61915 to develop generic device profiles for use within their own organisations. Users (product manufacturers and other organizations) should use the root device profiles together with the rules defined in this part of IEC 61915. This part of IEC 61915 allows users to make extensions to the root device profiles and/or generic device profiles. Where no suitable root device profile exists, the user may develop generic or specific device profiles using the rules defined in this part of IEC 61915. This part of IEC 61915 recommends the use of a profile exchange language for representation of the device profile information in order to facilitate the profile’s use by network tools and application software. NOTE 4 The types of devices may vary from simple devices, such as pilot lights, push-buttons and limit switches, to more complex devices with many bytes of information, such as motor controllers, semiconductor motor starters, etc.

Low-voltage switchgear and controlgear - Device profiles for networked industrial devices - Part 1: General rules for the development of device profiles

ICS
29.130.20
CCS
K30
发布
2007-11
实施
2007-11-29

Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements (IEC 60309-1:1999 + A1:2005, modified); German version EN 60309-1:1999 + A1:2007

ICS
29.120.30
CCS
K30
发布
2007-11
实施
2007-11-01

This part of IEC 60320 is applicable to two-pole appliance couplers for a.c. only, with or without earthing contact, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A, for household and similar general purposes and intended for the connection of a supply cord to electrical appliances or other electrical equipment for 50 Hz or 60 Hz supply. NOTE 1 Appliance inlets integrated or incorporated in appliances or other equipment are within the scope of this standard. The dimensional and general requirements of this standard apply to such inlets, but certain tests may not be relevant. NOTE 2 The requirements for connectors are based on the assumption that the temperature of the pins of the corresponding appliance inlets does not exceed 70 °C for connectors for cold conditions; 120 °C for connectors for hot conditions; 155 °C for connectors for very hot conditions. NOTE 3 Appliance couplers complying with this standard are suitable for use at ambient temperatures not normally exceeding 25 °C, but occasionally reaching 35 °C. NOTE 4 Appliance couplers complying with the standard sheets in this standard are intended for the connection of equipment having no special protection against moisture. If appliance couplers are used with equipment which may be subject to spillage of liquid in normal use then protection against moisture is to be provided by the equipment. NOTE 5 Special constructions may be required – in locations where special conditions prevail, for example, as in ships, vehicles and the like; – in hazardous locations, for example, where explosions are liable to occur.

Appliances couplers for household and similar general purposes - Part 1: General requirements

ICS
CCS
K30
发布
2007-11
实施

Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories (IEC 60309-2:1999 + A1:2005, modified); German version EN 60309-2:1999 + A1:2007

ICS
29.120.30
CCS
K30
发布
2007-11
实施
2007-11-01

This International Standard applies to interfaces between low-voltage switchgear, controlgear, and controllers (e.g. programmable controllers, personal computers, etc.). This standard does not apply to higher level industrial communication networks that have become known as fieldbuses and are considered by IEC subcommittee 65C. The purpose of this standard is to harmonize and define rules, components and requirements of a general nature applicable to industrial CDIs. Those features of the various CDI standards which can be considered as general have therefore been brought together in this part of IEC 62026. For each CDI, two main documents are necessary to determine all requirements and tests: a) this part, referred to as “IEC 62026-1” or “Part 1” in the relevant CDI parts covering the various types of CDIs; b) the specific CDI part of the IEC 62026 series. A specific CDI part may omit a general requirement if it is not applicable, or it may add to it if it is inadequate in the particular case, but it should not deviate from the requirement unless there is substantial technical justification. NOTE Product-specific requirements for products incorporating a CDI are given in the relevant product standards. These requirements apply in addition to those given in this International Standard.

Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - General rules

ICS
29.130.20
CCS
K30
发布
2007-10-31
实施
2007-10-31



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved