共找到 1074 条与 低压电器综合 相关的标准,共 72 页
Applies to controllers and starters, which may include a series mechanical switching device, intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c.
Low-voltage switchgear and controlgear Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters
Applies to control and protective switching devices (or equipment) (CPS), the main contacts of which are intended to be connected to circuits of rated voltage not exceeding 1 000 V a.c. or 1 500 V d.c. CPSs are intended to provide both protective and con
Low-voltage switchgear and controlgear Part 6-2: Multiple function equipment - Control and protective switching devices (or equipment) (CPS)
Low voltage electrical installations - Part 7-706: Requirements for special installations or locations - Conducting locations with restricted movement (IEC 60364-7-706:2005, modified); German implementation HD 60364-7-706:2007
Low-voltage electrical installations - Part 7-705: Requirements for special installations or locations - Agricultural and horticultural premises (IEC 60364-7-705:2006, modified); German implementation HD 60364-7-705:2007 + Corrigendum 1:2007
Low-voltage electrical installations - Part 7-740: Requirements for special installations or locations - Temporary electrical installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses (IEC 60364-7-740:2000, mo
Low-voltage electrical installations - Part 7-704: Requirements for special installations or locations - Construction and demolition site installations (IEC 60364-7-704:2005, modified); German implementation HD 60364-7-704:2007 + Cor. 1:2007
This part of IEC 60947 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field. These proximity switches are self-contained, have semiconductor switching elements(s) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz a.c. or 300 V d.c. This Standard is not intended to cover proximity switches with analogue outputs. The object of this standard is to state for proximity switches: – definitions; – classification; – characteristics; – product information; – normal service, mounting and transport conditions; – constructional and performance requirements; – tests to verify rated characteristics.
Low-voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches
이 규격은 단상 교류 300 V 이하, 정격 입력 2 kW 이하의 주로 가정에서 전열을 직
Electric cooker for household
이 규격은 단상 교류 220 V 또는 3상 교류 380 V, 380 V/440 V 겸용,
Electric storage tank water heaters
Specifies requirements for cord sets and interconnection cord sets for household and similar general purpose equipment. Does not apply to cord sets for industrial purposes nor to cord extension sets.
Electrical accessories - Cord sets and interconnection cord sets
이 규격은 주접점이 회로에 접속될, 주파수 60 Hz의 정격전압 교류 1 000 V 이하의
Low-voltage Air Circuit-Breaker(ACB)
Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters (IEC 60947-4-2:1999 + A1:2001 + A2:2006); German version EN 60947-4-2:2000 + A1:2002 + A2:2006
This part of IEC 60664 deals with insulation coordination for equipment within low-voltage systems. It applies to equipment for use up to 2 000 m above sea level having a rated voltage up to a.c. 1 000 V with rated frequencies up to 30 kHz, or a rated voltage up to d.c. 1 500 V. It specifies the requirements for clearances, creepage distances and solid insulation for equipment based upon their performance criteria. It includes methods of electric testing with respect to insulation coordination. The minimum clearances specified in this standard do not apply where ionized gases occur. Special requirements for such situations may be specified at the discretion of the relevant technical committee. This standard does not deal with distances – through liquid insulation, – through gases other than air, – through compressed air.
Insulation coordination for equipment within low-voltage systems - Principles, requirements and tests
This standard applies, when required by the relevant product standard, to switchgear and controlgear hereinafter referred to as "equipment" and intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c. It does not apply to low-voltage switchgear and controlgear assemblies which are dealt with in IEC 60439. NOTE In certain clauses or subclauses of this standard, the equipment covered by this standard is also referred to as "device", to be consistent with the text of such clauses or subclauses. The object of this standard is to state those general rules and requirements which are common to low-voltage equipment as defined in 1.1, including for example: – definitions; – characteristics; – information supplied with the equipment; – normal service, mounting and transport conditions; – constructional and performance requirements; – verification of characteristics and performance. Digital inputs and/or digital outputs contained in switchgear and controlgear, and intended to be compatible with programmable controllers (PLCs) are covered by Annex S.
Low-voltage switchgear and controlgear. General rules
이 규격은 국내 시장에 출시되는 전기전자제품(이하 제품이라 한다.)에 해당 유해물질을 규정
Guidance for self declaration of conformity about management of hazardous substance of electrical and electronics
This standard applies, when required by the relevant product standard, to switchgear and controlgear hereinafter referred to as "equipment" and intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c. It does not apply to low-voltage switchgear and controlgear assemblies which are dealt with in IEC 60439. NOTE In certain clauses or subclauses of this standard, the equipment covered by this standard is also referred to as "device", to be consistent with the text of such clauses or subclauses.
Low-voltage switchgear and controlgear - General rules
SN/T 1431 的本部分规定了进出口插头插座的要求、抽样、检验及检验结果的判定。 本部分适用于户内外使用的、家用和类似用途的、仅用于交流电、额定电压在 50V 以上但不超过 440V 额定电流不超过 32A 、专或不带接地插头的插头和固定式或移动式插座的进出口检验。也适用于装在电线组件中插头和装在电线加长组件中的插头和移动式插座的进出口的检验。
Rules for the inspection of low-voltage electrical apparatus for import and export.Part 3: Plugs and socket-outlets
Plugs, Receptacles, and Cable Connectors of the Pin and Sleeve Type third Edition
Plugs, Receptacles, and Cable Connectors of the Pin and Sleeve Type third Edition
This is the common ANCE, CSA, and UL standard for Metallic Outlet Boxes. It is the first edition of NMX-J-023/1-ANCE, the first edition of CSA C22.2 No. 18.1, and the tenth edition of UL 514A. This edition of CSA C22.2 No. 18.1 supersedes the requiremen
Metallic Outlet Boxes First Edition; UL 514A; NMX-J-023/1-ANCE; Supersedes C22.2 No 18-98-CAN/CSA; Update No 1 [Superseded: CSA C22.2 NO 18-98-CAN/CSA, CSA C22.2 NO 18-98-CAN/CSA, CSA C22.2 NO 18-98-CAN/CSA, CSA C22.2 NO 18-98-CAN/CSA, CSA C22.2 NO 18-92
Cette norme est publiée conjointement par l’Association de normalisation et de certification (ANCE), l’Association canadienne de normalisation (CSA) et les Underwriters Laboratories Inc. (UL). Des commentaires ou des propositions de modification relatif
Bo顃es de sortie m閠alliques
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved