K30 低压电器综合 标准查询与下载



共找到 1074 条与 低压电器综合 相关的标准,共 72

These requirements cover cord-connected, relocatable power taps rated 250 V AC or less and 20 A AC or less. A relocatable power tap (RPT) is intended only for indoor use as a temporary extension of a grounding alternating-current branch circuit for general use. A cord-connected product with less than three receptacle outlets that employs an electromagnetic interference filter or a transient voltage surge suppressor is covered under the Standard for Electromagnetic Interference Filters, UL 1283, and the Standard for Surge Protective Devices, UL 1449, respectively. A cord-connected product with three or more receptacle outlets that employs an electromagnetic interference filter shall also comply with the Standard for Electromagnetic Interference Filters, UL 1283. A cord-connected product with three or more receptacle outlets that employs a transient voltage surge suppressor shall also comply with the Standard for Surge Protective Devices, UL 1449. Telephone equipment and communication circuit protectors included in a RPT shall comply with the requirements in the Standard for Telephone Equipment, UL 1459, and the requirements in the Standard for Secondary Protectors for Communications Circuits, UL 497A, respectively. A RPT that incorporates an antenna discharge unit or provides antenna connections to a television, a high-voltage video product, or antenna shall comply with the applicable requirements in the Standard for Antenna Discharge Units, UL 452, and the Standard for Audio-Video Products and Accessories, UL 1492. A cord-connected product that employs ground-fault protection is investigated under the requirements in the Standard for Ground-Fault Circuit Interrupters, UL 943. A cord-connected RPT is not intended to be connected to another cord-connected RPT. This standard does not cover RPTs intended for use with medical equipment. Medical equipment is typically intended for use in General Patient Care Areas or Critical Patient Care Areas as defined by Article 517 of the National Electrical Code for

UL Standard for Safety Relocatable Power Taps COMMENTS DUE: January 21, 2008

ICS
29.120.30
CCS
K30
发布
2007
实施

KS X IEC 62026-1 문서의 일반 규정의 제안은 특별히 요청되는 이 국제표준에 부

Low-voltage switchgear and controlgear-Controller-device interfaces(CDIs)-Part 2:Actuator sensor interface(AS-i)

ICS
29.130.20
CCS
K30
发布
2006-12-26
实施
2006-12-26

Applies to transfer switching equipment (TSE) to be used in power systems with interruption of the supply to the load during transfer, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.

Low-voltage switchgear and controlgear Part 6-1: Multiple function equipment - Transfer switching equipment

ICS
29.130.20
CCS
K30
发布
2006-12-15
实施

Substation cable distribution boards (SCDBs) and cable distribution cabinets (CDCs) for power distribution in networks shall comply with all the requirements of IEC 60439-1 (1999) if not otherwise indicated hereinafter and shall also comply with the particular requirements contained in this publication. This standard gives supplementary requirements for substation cable distribution boards (SCDBs) and cable distribution cabinets (CDCs), which are stationary, type-tested assemblies (TTA). They are used for the distribution of electrical energy in three-phase systems. Opentype ASSEMBLY are not covered by this standard. Individual components, such as fuses and switching devices that comply with other standards, shall also comply with the supplementary requirements of this standard. The object of this standard is to state the definitions and to specify the service conditions, construction requirements, technical characteristics and tests for SCDBs and CDCs. Higher performance and test levels may be required for particular networks, for example, those with meshed connections.

Low-voltage switchgear and controlgear assemblies - Particular requirements for assemblies for power distribution in public networks

ICS
29.130.20
CCS
K30
发布
2006-11-30
实施
2006-11-30

Applies to plugs and fixed or portable socket-outlets for a.c. only, with or without earthing contact, with a rated voltage above 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either ind

Plugs and socket-outlets for household and similar purposes Part 1: General requirements

ICS
29.120.30
CCS
K30
发布
2006-11-10
实施

Applies to plugs and socket-outlets, cable couplers and appliance couplers, with a rated operating voltage not exceeding 690 V d.c. or a.c. and 500 Hz a.c., and a rated current not exceeding 250 A, primarily intended for industrial use, either indoors or

Plugs, socket-outlets and couplers for industrial purposes Part 1: General requirements

ICS
29.120.30
CCS
K30
发布
2006-11-10
实施
2006-11-10

Applies to plugs and socket-outlets, cable couplers and appliance couplers with a rated operating voltage not exceeding 690 V, 500 Hz and a rated current not exceeding 125 A, primarily intended for industrial use, either indoors or outdoors. Also applies

Plugs, socket-outlets and couplers for industrial purposes Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories

ICS
29.120.30
CCS
K30
发布
2006-11-10
实施
2006-11-10

Applies to busbar trunking systems (BTS) and their accessories for feeding and distributing electrical power in residential, retail, public, agricultural and industrial premises. Also applies to busbar trunking systems that are designed to incorporate co

Low-voltage switchgear and controlgear assemblies Part 2: Particular requirements for busbar trunking systems (busways)

ICS
29.130.20
CCS
K30
发布
2006-11-10
实施

Gives supplementary requirements for substation cable distribution boards and cable distribution cabinets, which are stationary, type-tested assemblies (TTA) for outdoor installation in places which are exposed to the public, but where only skilled perso

Low-voltage switchgear and controlgear assemblies Part 5: Particular requirements for assemblies for power distribution in public networks

ICS
29.130.20;29.240.30
CCS
K30
发布
2006-11-03
实施

Applies to connecting devices with screwless-type clamping units primarily suitable for connecting unprepared conductors. Covers low-voltage circuits with a rated voltage not exceeding 1 000 V a.c. up to and including 1 000 Hz and 1 500 V d.c. where elec

Connecting devices for low-voltage circuits for household and similar purposes Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units

ICS
29.120.20
CCS
K30
发布
2006-10-27
实施

Applies to self-contained products that combine within a single enclosure, a socket-outlet or connector in accordance with IEC 60309-1 or IEC 60309-2 (published in South Africa as identical adoptions under the designations SANS 60309-1 and SANS 60309-2)

Plugs, socket-outlets and couplers for industrial purposes Part 4: Switched socket-outlets and connectors with or without interlock

ICS
29.120.30
CCS
K30
发布
2006-10-27
实施
2006-10-27

Applies to connecting devices with insulation-piercing clamping units primarily suitable for connecting insulated unprepared conductors. Covers low-voltage circuits with a rated voltage not exceeding 1 000 V a.c. up to and including 1 000 Hz and 1 500 V

Connecting devices for low-voltage circuits for household and similar purposes Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units

ICS
29.120.20
CCS
K30
发布
2006-10-27
实施

Applies to connecting devices with screw-type clamping units primarily suitable for connecting unprepared conductors. Covers low-voltage circuits with a rated current not exceeding 1 000 V a.c. up to and including 1 000 Hz and 1 500 V d.c. where electric

Connecting devices for low-voltage circuits for household and similar purposes Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units

ICS
29.120.20
CCS
K30
发布
2006-10-27
实施

Applies to connecting devices as separate entities for the connection of two or more electrical copper conductors rigid (solid or stranded) or flexible, having a cross-sectional area of 0,2 square millimetres up to and including 35 square millimetres and

Connecting devices for low-voltage circuits for household and similar purposes Part 1: General requirements

ICS
29.120.20
CCS
K30
发布
2006-10-27
实施

Applies to twist-on connecting devices for connecting two or more unprepared rigid and/or flexible copper conductors having a cross-sectional area of 0,5 square millimetres up to and including 16 square millimetres, the total cross-sectional area of the

Connecting devices for low-voltage circuits for household and similar purposes Part 2-4: Particular requirements for twist-on connecting devices

ICS
29.120.20
CCS
K30
发布
2006-10-27
实施

本标准规定了GJB 4337-2002《耐环境圆形电连接器总规范》所要求的绝缘安装板接触件的孔位排列、尺寸和定位角度等。 本标准适用于GJB 4337-2002《耐环境圆形电连接器总规范》规定的耐环境圆形电连接器绝缘安装板的设计、制造。

Insert contact arrangements for environment resisting circular electrical connectors

ICS
CCS
K30
发布
2006-10-20
实施
2007-01-01

Approval and test specification-Plugs and socket-outlets; Amendment No.1

ICS
CCS
K30
发布
2006-10-11
实施

This clause of Part 1 is applicable except as follows. Replacement of the first paragraph: This part of IEC 60884 applies to socket-outlets for a.c. only, with or without earthing contact, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A, which are integrated or intended to be incorporated in or fixed to appliances, hereafter referred to as socket-outlets for appliances. Addition after the fourth paragraph: Socket-outlets for appliances are provided with means for fixing into appropriate mounting boxes, if intended also for use in fixed installations. Socket-outlets for appliances are intended to be used in stationary equipment and appliances such as office machines, computers, audio-visual and video equipment, range hoods, ranges, etc. If necessary, the use of socket-outlets for appliances is indicated in the standards for the appropriate equipment or appliance. The temperature around socket-outlets for appliances must not exceed 35 °C.

Plugs and socket-outlets for household and similar purposes - Part 2-2: Particular requirements for socket-outlets for appliances

ICS
29.120.30
CCS
K30
发布
2006-10
实施
2006-10-13

This standard applies to circuit-breakers, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers. It applies whatever the rated currents, the method of construction or the proposed applications of the circuit-breakers may be. The requirements for circuit-breakers which are also intended to provide earth-leakage protection are contained in Annex B. The additional requirements for circuit-breakers with electronic over-current protection are contained in Annex F. The additional requirements for circuit-breakers for IT systems are contained in Annex H. The requirements and test methods for electromagnetic compatibility of circuit-breakers are contained in Annex J. The requirements for circuit-breakers not fulfilling the requirements for over-current protection are contained in Annex L. The requirements for modular residual current devices (without integral current breaking device) are contained in Annex M. The requirements and test methods for electromagnetic compatibility of circuit-breaker auxiliaries are contained in Annex N. Supplementary requirements for circuit-breakers used as direct-on-line starters are given in IEC 60947-4-1, applicable to low-voltage contactors and starters. The requirements for circuit-breakers for the protection of wiring installations in buildings and similar applications, and designed for use by uninstructed persons, are contained in IEC 60898. The requirements for circuit-breakers for equipment (for example electrical appliances) are contained in IEC 60934. For certain specific applications (for example traction, rolling mills, marine service) particular or additional requirements may be necessary. NOTE Circuit-breakers which are dealt with in this standard may be provided with devices for automatic opening under predetermined conditions other than those of over-current and undervoltage as, for example, reversal of power or current. This standard does not deal with the verification of operation under such pre-determined conditions. The object of this standard is to state: a) the characteristics of circuit-breakers; b) the conditions with which circuit-breakers shall comply with reference to: 1) operation and behaviour in normal service; 2) operation and behaviour in case of overload and operation and behaviour in case of short-circuit, including co-ordination in service (discrimination and back-up protection); 3) dielectric properties; c) tests intended for confirming that these conditions have been met and the methods to be adopted for these tests; d) information to be marked on or given with the apparatus.

Low-voltage switchgear and controlgear — Part 2: Circuit-breakers

ICS
29.130.20
CCS
K30
发布
2006-09-29
实施

This standard applies to circuit-breakers, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers. It applies whatever the rated currents, the method of construction or the proposed applications of the circuit-breakers may be. The requirements for circuit-breakers which are also intended to provide earth-leakage protection are contained in Annex B. The additional requirements for circuit-breakers with electronic over-current protection are contained in Annex F. The additional requirements for circuit-breakers for IT systems are contained in Annex H. The requirements and test methods for electromagnetic compatibility of circuit-breakers are contained in Annex J. The requirements for circuit-breakers not fulfilling the requirements for over-current protection are contained in Annex L. The requirements for modular residual current devices (without integral current breaking device) are contained in Annex M. The requirements and test methods for electromagnetic compatibility of circuit-breaker auxiliaries are contained in Annex N. Supplementary requirements for circuit-breakers used as direct-on-line starters are given in IEC 60947-4-1, applicable to low-voltage contactors and starters. The requirements for circuit-breakers for the protection of wiring installations in buildings and similar applications, and designed for use by uninstructed persons, are contained in IEC 60898. The requirements for circuit-breakers for equipment (for example electrical appliances) are contained in IEC 60934. For certain specific applications (for example traction, rolling mills, marine service) particular or additional requirements may be necessary. NOTE Circuit-breakers which are dealt with in this standard may be provided with devices for automatic opening under predetermined conditions other than those of over-current and undervoltage as, for example, reversal of power or current. This standard does not deal with the verification of operation under such pre-determined conditions. The object of this standard is to state: a) the characteristics of circuit-breakers; b) the conditions with which circuit-breakers shall comply with reference to: 1) operation and behaviour in normal service; 2) operation and behaviour in case of overload and operation and behaviour in case of short-circuit, including co-ordination in service (discrimination and back-up protection); 3) dielectric properties; c) tests intended for confirming that these conditions have been met and the methods to be adopted for these tests; d) information to be marked on or given with the apparatus.

Low-voltage switchgear and controlgear - Circuit-breakers

ICS
29.130.20
CCS
K30
发布
2006-09-29
实施
2006-09-29



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号