K30 低压电器综合 标准查询与下载



共找到 1074 条与 低压电器综合 相关的标准,共 72

This standard applies to two-pole socket-outlets with earthing contact, 16 A 250 V a.c.#,,#

Two-pole socket-outlets with earthing contact, 16 A 250 V a.c. - Part 1: Main dimensions

ICS
29.120.30
CCS
K30
发布
2006-01
实施

This document specifies standard service conditions, standard ratings, environmental performance requirements, and testing requirements for communications networking devices installed in electric power substations. It does not cover such equipment designed for operation in other environments, such as office locations. It does not cover such equipment used in protective relaying applications, for which IEEE Std C37.90-1989 [B6]1, IEEE Std C37.90.1-2002 [B7], IEEE Std C37.90.2-1995 [B8], and IEEE Std C37.90.3-2001 [B9] apply.

Environmental and testing requirements for communications networking devices in electric power substations; Corrigendum 1

ICS
CCS
K30
发布
2006
实施

This International Standard deals with the techniques for sampling free gases from gascollecting relays and for sampling oil from oil-filled equipment such as power and instrument transformers, reactors, bushings, oil-filled cables and oil-filled tank-type capacitors. Three methods of sampling free gases and three methods of sampling oil are described; the choice between the methods often depends on the apparatus available and on the quantity of oil needed for analysis. Before analysing the gases dissolved in oil, they must first be extracted from the oil. Three basic methods ar e described, one using extraction by vacuum (Toepler and parti al degassing), another by displacement of the dissolved gases by bubbling the carrier gas through the oil sample (stripping), and the last one by partition of gases between the oil sample and a small volume of the carrier gas (head space). The gases are analysed quantitatively after extraction by gas chromatography; a method of analysis is described. Free gases from gas-collecting relays are analysed without preliminary treatment. The preferred method for assuring the performance of the gas extraction and analysis equipment, considered together as a single system, is to degas samples of oil prepared in the laboratory and containing known concentrations of gases (“gas-in-oil standards”) and quantitatively analyse the gases extracted. Two methods of preparing gas-in-oil standards are described. For daily calibration checks of the chromatograph, it is convenient to use a standard gas mixture containing a suitable known amount of each of the gas components to be in a similar ratio to the commons ratios of the gases extracted from transformer oils. The techniques described take account, on the one hand, of the problems peculiar to analyses associated with acceptance testing in the factory, where gas contents of oil are generally very low and, on the other hand, of the problems imposed by monitoring equipment in the field, where transport of samples may be by un-pressurized air freight and where considerable differences in ambient temperature may exist between the plant and the examining laboratory.

Oil-filled electrical equipment - Sampling of gases and of oil for analysis of free and dissolved gases - Guidance

ICS
17.220.99;29.040.10;29.035.99
CCS
K30
发布
2005-12-02
实施
2005-12-02

Applicable to insulating gloves and mitts. Six classes of gloves, differing in electrical characteristics, and six categories of gloves, differing in properties related to acid, oil, ozone, mechanical strength (higher level) and a combination of all, and also for extremely low temperatures are provided.

Live working - Gloves of insulating material

ICS
13.260;13.340.40
CCS
K30
发布
2005-12-02
实施

This standard applies to plugs and socket-outlets, cable couplers and appliance couplers, with a rated operating voltage not exceeding 690 V d.c. or a.c. and 500 Hz a.c, and a rated current not exceeding 250 A, primarily intended for industrial use, either indoors or outdoors. The list of preferred ratings is not intended to exclude other ratings. This standard applies to plugs and socket-outlets, cable couplers and appliance couplers, hereinafter referred to as accessories, for use when the ambient temperature is normally within the range of -25 °C to +40 °C. These accessories are intended to be connected to cables of copper or copper alloy only. This standard applies to accessories with screwless type terminals or insulation piercing terminals, with a rated current up to and including. 16 A for Series I and 20 A for Series II. The use of these accessories on building sites and for agricultural, commercial and domestic applications is not precluded. Socket-outlets or appliance inlets incorporated in or fixed to electrical equipment are within the scope of this standard. This standard also applies to accessories intended to be used in extra-low voltage installations. This standard does not apply to accessories primarily intended for domestic and similar general purposes. In locations where special conditions prevail, for example on board ship or where explosions are liable to occur, additional requirements may be necessary.

Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements

ICS
29.120.30;29.120.39
CCS
K30
发布
2005-12
实施

Provides detailed specifications relating to the electrical and mechanical construction of emergency stop devices with mechanical latching function and to their testing. Is applicable to electrical control circuit devices and switching elements which are

Low-voltage switchgear and controlgear Part 5-5: Control circuit devices and switching elements - Electrical emergency stop device with mechanical latching function

ICS
29.120.99;29.130.20
CCS
K30
发布
2005-11-21
实施

This International Standard applies to twist-on connecting devices for connecting two or more unprepared rigid and/or flexible copper conductors having a cross-sectional area of 0,5 mm2 up to and including 16 mm2 and complying with IEC 60228, the total cross-sectional area of the connected conductors not exceeding 35 mm2. It covers low voltage circuits up to 1 000 V a.c. and 1 500 V d.c. where electrical energy is utilized for household and similar purposes. This standard covers TOCDs primarily designed for application by hand. However, certain TOCDs, for example for large cross-sections, may require the use of a tool designed for that particular TOCD.

Connecting devices for low voltage circuits for household and similar purposes - Particular requirements for twist-on connecting devices

ICS
29.120.20
CCS
K30
发布
2005-11-09
实施
2005-11-09

Information is provided to users and manufacturers of surge-protective devices (SPDs) about the interactions that can occur between SPDs and power system disturbances. Applies to SPDs manufactured to be connected to 50 or 60 Hz ac power circuits rated at 100-1000 V rms.

Guide on Interactions Between Power System Disturbances and Surge Protective Devices

ICS
13.260
CCS
K30
发布
2005-10-28
实施

Applies to proximity devices with an enhanced resistance to failure (PDF). Specifies requirements for four different types of PDF.

Low-voltage switchgear and controlgear Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDF)

ICS
29.120.99;29.130.20
CCS
K30
发布
2005-10-28
实施

Describes the principles for the selection, operation, location and coordination of SPDs connected to telecommunication and signalling networks with nominal system voltages up to 1 000 V r.m.s. a.c. and 1 500 V d.c. Also addresses SPDs that incorporate protection for signalling lines and power lines in the same enclosure.

Low-voltage surge protective devices Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles

ICS
29.120.50
CCS
K30
发布
2005-10-14
实施

이 규격은 KS C IEC 60664-1에 따라서 제품의 설계 결정에 관한 요구 사항을 결

Insulation coordination for equipment within low-voltage systems-Part 2-1:Application guide-Dimensioning procedure worksheets and dimensioning examples

ICS
29.080.30
CCS
K30
发布
2005-10-06
实施
2005-10-06

이 규격은 저압 장치 및 설비에서 발생할 수 있는 여러 종류의 서지 과전압에 대해 설명하고

Insulation coordination for equipment within low-voltage systems-Part 2-2:Interface considerations-Application guide

ICS
29.080.30
CCS
K30
发布
2005-10-06
实施
2005-10-06

This is Amendment 1 IEC 60309-1-2005 (Plugs,socket-outlets and couplers for industrial purposes-Part1:General requirements )

Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements; Amendment 1

ICS
29.120.30
CCS
K30
发布
2005-10
实施
2005-12-09

This is Amendment 1 IEC 60309-2-2005 (Plugs,socket-outlets and couplers for industrial purposes-Part2:Dimensional interchangeability requrements for pin and contact-tube accessories)

Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories; Amendment 1

ICS
29.120.30
CCS
K30
发布
2005-10
实施

Low-voltage electrical installations - Update of june 2005 to NF C15-100:2002.

ICS
29.020;91.140.50
CCS
K30
发布
2005-06-01
实施

추가 요구 사항은 교류 정격 전압 1 000 V까지의 회로 또는 직류 정격 전압 1 500

Low-voltage fuses-Part 4:Supplementary requirementsfor fuse-links for the protection of semiconductor devices

ICS
29.120.50
CCS
K30
发布
2005-02-07
实施
2005-02-07

다음에 나오는 추가 요구 사항은, 예를 들어 그림 1(I)와 2(I)에서 제시된 치수를 만

Low-voltage fuses-Part 2-1:Supplementaryrequirements for fuses for use by authorized persons(fuses mainly for industrial application)-Sections I to VI:Examples of types of standardized fuses

ICS
29.120.50
CCS
K30
发布
2005-02-07
实施
2005-02-07

Applies to type-tested assemblies (TTA) intended for used on construction sites, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (

Low-voltage switchgear and controlgear assemblies Part 4: Particular requirements for assemblies for construction sites (ACS)

ICS
29.130.20
CCS
K30
发布
2005-01-28
实施

Request for comments on the proposed revisions to the Fourth Edition of the Standard for Terminal Blocks, UL 1059.

Standard for Safety for Terminal Blocks

ICS
29.120.20
CCS
K30
发布
2005-01-01
实施

This standard establishes the requirements for a distinctive symbol and labels to be used to identify materials that are lead-free (Pb-free) and are capable of providing Pb-free 2nd level interconnects, and for indicating certain types of Pb-free material and the maximum assembly temperature. It also establishes the requirements for labeling a bare board if the base resin is halogen free and the type of conformal coating used after assembly.

Marking, Symbols and Labels for Identification of Lead-Free and Other Reportable Materials in Lead-Free Assemblies, Components and Devices

ICS
CCS
K30
发布
2005-01-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved