K31 低压配电电器 标准查询与下载



共找到 2417 条与 低压配电电器 相关的标准,共 162

UL Standard for Safety Solid-State Dimming Controls - Section / Paragraph Reference: Paragraph 7.1.6 Subject: Lamp compatibility information (Edition 1: January 02, 1996)

ICS
CCS
K31
发布
2015-05-15
实施

Low-voltage fuses - Part 1: General requirements (IEC 60269-1:2006 + A1:2009 + A2:2014); German version EN 60269-1:2007 + A1:2009 + A2:2014

ICS
29.120.50
CCS
K31
发布
2015-05
实施

UL Standard for Safety Industrial Control Panels - Section / Paragraph Reference: Table SB4.4 Subject: Three phase transformer secondary available short circuit currents (Edition 2: December 20, 2013)

ICS
CCS
K31
发布
2015-04-10
实施

Tap-changers - Part 1: Performance requirements and test methods (IEC 60214-1:2014); German version EN 60214-1:2014

ICS
29.130.01;29.180
CCS
K31
发布
2015-04
实施

Reed switches. Generic specification

ICS
29.120.70
CCS
K31
发布
2015-03-31
实施
2015-03-31

General requirements for fuses for the protection of low voltage cables and lines

ICS
29.120.50
CCS
K31
发布
2015-03-20
实施

Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switchdisconnectors and fuse-combination units (IEC 60947-3:2008 + A1:2012); German version EN 60947-3:2009 + A1:2012, Corrigendum to DIN EN 60947-3 (VDE 0660-107):2012-12; (IEC-Cor

ICS
29.130.20
CCS
K31
发布
2015-03
实施

Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - National Supplement 1: Protection of special electrical systems

ICS
29.120.50
CCS
K31
发布
2015-03
实施

This part of IEC 60898 applies to a.c. air-break circuit-breakers for operation at 50 Hz@ 60 Hz or 50/60 Hz@ having a rated voltage not exceeding 440 V (between phases)@ a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25 000 A. As far as possible@ it is in line with the requirements contained in IEC 60947-2. These circuit-breakers are intended for the protection against overcurrents of wiring installations of buildings and similar applications; they are designed for use by uninstructed people and for not being maintained. They are intended for use in an environment with pollution degree 2. They are suitable for isolation. Circuit-breakers of this standard@ with exception of those rated 120 V or 120/240 V (see Table 1)@ are suitable for use in IT systems. This standard also applies to circuit-breakers having more than one rated current@ provided that the means for changing from one discrete rating to another is not accessible in normal service and that the rating cannot be changed without the use of a tool. This standard does not apply to ?C circuit-breakers intended to protect motors; ?C circuit-breakers@ the current setting of which is adjustable by means accessible to the user. For circuit-breakers having a degree of protection higher than IP20 according to IEC 60529@ for use in locations where arduous environmental conditions prevail (e.g. excessive humidity@ heat or cold or deposition of dust) and in hazardous locations (e.g. where explosions are liable to occur)@ special constructions may be required. This standard does not apply to circuit-breakers for a.c. and d.c. operation@which is covered by IEC 60898-2. This standard does not apply to circuit-breakers which incorporate residual current tripping devices@ which is covered by IEC 61009-1@ IEC 61009-2-1@ and IEC 61009-2-2. A guide for co-ordination under short-circuit conditions between a circuit-breaker and another short-circuit protective device (SCPDs) is given in Annex D. For more severe overvoltage conditions@ circuit-breakers complying with other standards (e.g. IEC 60947-2) should be used. For an environment with a higher pollution degree@ enclosures giving the appropriate degree of protection should be used. NOTE 1 Circuit-breakers within the scope of this standard can also be used for protection against electric shock in case of fault@ depending on their tripping characteristics and on the characteristics of the installation. The criterion of application for such purposes is dealt with by installation rules. This standard contains all requirements necessary to ensure compliance with the operational characteristics required for these devices by type tests. It also contains the details relative to test requirements and methods of testing necessary to ensure reproducibility of test results. This standard states a) the characteristics of circuit-breakers; b) the conditions with which circuit-breakers shall comply@ with reference to: 1) their operation and behaviour in normal service; 2) their operation and behaviour in case of overload; 3) their operation and behaviour in case of short-circuits up to their rated short-circuit capacity; 4) their dielectric properties; c) the tests intended for confirming that these conditions have been met and the methods to be adopted for the tests; d) the data to be marked on the devices; e) the test sequences to be carried out and the number of samples (see Annex C); f) the co-ordination under short-circuit conditions with another short-circuit protective device (SCPD) associated in the same circuit (see Annex D); g) the routine tests to be carried out on each circuit-breaker to reveal unacceptable variations in material or manufacture@ likely to affect safety (see Annex I).

Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation

ICS
29.120.50
CCS
K31
发布
2015-03
实施
2015-03-26

Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic switches

ICS
29.120.40
CCS
K31
发布
2015-03
实施

Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic switches

ICS
29.120.40
CCS
K31
发布
2015-03
实施
2015-04-01

本标准规定电力配网低压线路末端低电压提升装置(以下简称装置)的分类、使用条件、技术要求、试验方法和检验规则以及标志、包装、运输和存储等。 本标准适用于户外正常使用条件下,额定绝缘电压660 V,额定工作电压交流400 V及以下,频率50Hz的三相或单相线路末端低电压提升装置。

General technical requirements for low-voltage lifting devices at the end of low-voltage lines in power distribution networks

ICS
29.130
CCS
K31
发布
2015-02-28
实施
2015-06-01

Miniature fuses - Part 1: Definitions for miniature fuses and general requirements for miniature fuse-links

ICS
29.120.50
CCS
K31
发布
2015-02
实施

Miniature fuses - Part 1: Definitions for miniature fuses and general requirements for miniature fuse-links; Amendment 2

ICS
29.120.50
CCS
K31
发布
2015-02
实施
2015-02-20

Miniature fuses - Part 3: Sub-miniature fuse-links

ICS
29.120.50
CCS
K31
发布
2015-01
实施

Low-voltage switchgear and controlgear assemblies. Part 3. Distribution boards intended to be operated by ordinary persons

ICS
29.130.20
CCS
K31
发布
2015
实施
2017-03-01

Low-voltage switchgear and controlgear. Part 7-4. Ancillary equipment. PCB terminal blocks for copper conductors

ICS
29.130.20
CCS
K31
发布
2015
实施
2017-03-01

Low-voltage switchgear and controlgear assemblies. Part 4. Particular requirements for assemblies for construction sites

ICS
29.130.20
CCS
K31
发布
2015
实施
2017-03-01

La présente partie de l'IEC 60127 s'applique aux ensembles-porteurs pour éléments de remplacement à cartouches conformes à l'IEC 60127-2 et aux éléments de remplacement subminiatures conformes à l'IEC 60127-3 pour la protection d'appareils électriques, de matériels électroniques et de leurs éléments constituants, normalement destinés à être utilisés à l'intérieur de bâtiments.

Miniature fuses - Part 6 : fuse-holders for miniature fuse-links

ICS
29.120.50
CCS
K31
发布
2014-12-12
实施
2014-12-12

UL Standard for Safety Fuseholders - Part 1: General Requirements - Section / Paragraph Reference: Multiple: definitions, construction, performance Subject: Allow for multilple cables per phase smaller than 1/0 AWG (Edition 1: February 28, 2007)

ICS
CCS
K31
发布
2014-12-08
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号