K35 防爆电器 标准查询与下载



共找到 919 条与 防爆电器 相关的标准,共 62

Explosive atmospheres - Part 0: Equipment - General requirements; Supplement 1: Interpretation Sheet 1 (IEC 60079-0/ISH1:2013)

ICS
29.260.20
CCS
K35
发布
2014-06
实施

La présente partie de la série CEI 60079 contient les exigences spécifiques de conception, de sélection, de construction et d'inspection initiale applicables aux installations électriques situées ou en relation avec des atmosphères explosives.

Explosive atmospheres - Part 14 : electrical installations design, selection and erection

ICS
29.260.20
CCS
K35
发布
2014-05-30
实施
2014-05-30

Le présent amendement modifie les paragraphes 9.3.3, 29.3, 29.9, 29.10 et 29.16 ainsi que les Annexes ZY et ZZ de la norme homologuée NF EN 60079-0, de janvier 2013.Le présent document entre dans le champ d'application de la Directive ATEX no 94/9/CE du 23/03/1994.

Explosive atmospheres - Part 0 : equipment - General requirements

ICS
29.260.20
CCS
K35
发布
2014-03-26
实施
2014-03-26

Explosive atmospheres - Part 25: Intrinsically safe electrical systems (IEC 60079-25:2010); German version EN 60079-25:2010, Cori gendum to DIN EN 60079-25 (VDE 0170-10-1):2011-06; German version EN 60079-25:2010/AC:2013

ICS
29.260.20
CCS
K35
发布
2014-01
实施

Explosive atmospheres. Part 35-1. Caplights for use in mines susceptible to firedamp. General requirements and test methods in relation to the risk of explosion

ICS
29.260.20;73.100.20
CCS
K35
发布
2014
实施
2016-12-01

本标准规定了额定工作电压380V及以下的可燃性粉尘环境用的、用外壳和限制表面温度保护的粉尘防爆操作柱(以下简称操作柱)的产品分类,基本参数、技术要求、试验方法、检测规则、标志、包装、运输和贮存。本标准适用于可燃性粉尘环境用的、用外壳和限制表面温度保护的粉尘防爆操作柱。本标准不适用于:a) 可能同时出现或者分别出现可燃性气体和可燃性粉尘的环境中使用的电气设备;b) 本标准不适用于那些不需要大气中的氧即可燃烧的炸药粉尘或自燃引火物质;c) 本标准不适用于沼气和/或可燃性粉尘引起危险的煤矿井下用操作柱。本标准未考虑由粉尘散发出来的可燃性或毒性气体引起的危险。

Electrical apparatus for use in the presence of combustible dust.Dust explosion-proof operating post by enclosures and surface temperature limitation-specification for apparatus

ICS
29.260.20
CCS
K35
发布
2013-12-31
实施
2014-07-01

本标准规定了额定工作电压460V及以下的可燃性粉尘环境用、用外壳和限制表面温度保护的、粉尘防爆照明(动力)配电箱(以下简称配电箱)的产品分类、基本参数、技术要求、试验方法、检验规则、标志、包装、运输和贮存。本标准适用于可燃性粉尘环境用电气设备用外壳和限制表面温度保护的粉尘防爆照明 (动力)配电箱。本标准不适用于:a)可能同时出现或分别出现可燃性气体和可燃性粉尘的环境中使用的电气设备;b)不需要大气中的氧即可燃烧的炸药粉尘或自燃引火物质;c)沼气和/或可燃性粉尘引起危险的煤矿井下用配电箱。本标准未考虑由粉尘散发出来的可燃性或毒性气体引起的危险。

Electrical apparatus for use in the presence of combustible dust.Dust lighting (power) distribution box by enclosures and surface temperature limitation-specification for apparatus

ICS
29.260.20
CCS
K35
发布
2013-12-31
实施
2014-07-01

本标准规定了防爆低压电气用接线端子(以下简称接线端子)的产品分类、结构型式、技术要求、试验方法、检验规则、标志、包装、运输及贮存。本标准适用于接线端子的设计、制造与检验。

Connectiong terminals for explosion proof low voltage electric apparatus

ICS
29.260.20
CCS
K35
发布
2013-12-31
实施
2014-07-01

本标准规定了爆炸性环境用防爆照明(动力)配电箱(以下简称配电箱)的产品分类、基本参数、技术要求、试验方法、检验规则、标志、包装、运输和贮存等内容。 本标准适用于爆炸性环境用防爆照明(动力)配电箱。

Electrical apparatus for explosive gas atmospheres .Explosion-proof lighting (power) distribution box

ICS
29.260.20
CCS
K35
发布
2013-12-31
实施
2014-07-01

Guidelines for Implementation of Safety Production Standardization in Metal and Nonmetal Mining and Construction Enterprises

ICS
29.260.20
CCS
K35
发布
2013-12-25
实施
2014-02-01

UL Standard for Safety Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I@ II@ and III@ Division 1@ Hazardous (Classified) Locations (Eighth Edition; Reprint with Revisions Through and Including October 16@ 2015)

ICS
29.260.20
CCS
K35
发布
2013-12-06
实施

Explosive atmospheres. Equipment protection by special protection "s"

ICS
29.260.20
CCS
K35
发布
2013-11-30
实施
2013-11-30

Explosion-proof and dust-ignition-proof electrical equipment for use in hazardous (classified) locations

ICS
29.260.20
CCS
K35
发布
2013-11-22
实施

Explosive atmospheres - Part 0: Equipment - General requirements; Interpretation sheet 1

ICS
29.260.20
CCS
K35
发布
2013-11
实施

Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"

ICS
29.260.20
CCS
K35
发布
2013-11
实施

This part of the IEC 60079 series contains the specific requirements for the design@ selection@ erection and initial inspection of electrical installations in@ or associated with@ explosive atmospheres. Where the equipment is required to meet other environmental conditions@ for example@ protection against ingress of water and resistance to corrosion@ additional protection requirements may be necessary. The requirements of this standard apply only to the use of equipment under standard atmospheric conditions as defined in IEC 60079-0. For other conditions@ additional precautions may be necessary@ and the equipment should be certified for these other conditions. For example@ most flammable materials and many materials which are normally regarded as non-flammable might burn vigorously under conditions of oxygen enrichment. NOTE 1 The standard atmospheric conditions defined in IEC 60079-0 relate to the explosion characteristics of the atmosphere and not the operating range of the equipment i.e. Temperature: ?C20 ??to 60 ?? Pressure: 80 kPa (0@8 bar) to 110 kPa (1@1 bar); and air with normal oxygen content@ typically 21 % v/v. These requirements are in addition to the requirements for installations in non-hazardous areas. NOTE 2 For voltages up to 1 000 V a.c. or 1 500 V d.c. requirements of this standard are based on installation requirements in the IEC 60364 series@ but other relevant national requirements can apply. This standard applies to all electrical equipment including fixed@ portable@ transportable and personal@ and installations@ permanent or temporary. This standard does not apply to ?C electrical installations in mines susceptible to firedamp; NOTE 3 This standard can apply to electrical installations in mines where explosive gas atmospheres other than firedamp can be formed and to electrical installations in the surface installation of mines. ?C inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing); ?C rooms used for medical purposes; ?C electrical installations in areas where the hazard is due to flammable mist. NOTE 4 Additional guidance on the requirements for hazards due to hybrid mixtures of dust or flyings and flammable gas or vapour is provided in Annex M. No account is taken in this Standard of the toxic risks that are associated with flammable gases@ liquids and dusts in concentrations that are usually very much less than the lower explosive limit. In locations where personnel may be exposed to potentially toxic concentrations of flammable material@ appropriate precautions should be taken. Such precautions are outside the scope of this Standard.

Explosive atmospheres - Part 14: Electrical installations design, selection and erection

ICS
29.260.20
CCS
K35
发布
2013-11
实施
2013-11-30

This part of the IEC 60079 series applies to users and covers factors directly related to the inspection and maintenance of electrical installations within hazardous areas only@ where the hazard may be caused by flammable gases@ vapours@ mists@ dusts@ fibres or flyings. It does not include: other fundamental installation and inspection requirements for electrical installations; the verification of electrical equipment; the repair and reclamation of explosion protected equipment (see IEC 60079-19). This standard supplements the requirements of IEC 60364-6. In the case of dusts@ fibres or flyings the level of housekeeping may influence the inspection and maintenance requirements. This standard is intended to be applied where there can be a risk due to the presence of explosive gas or dust mixtures with air or combustible dust layers under normal atmospheric conditions. It does not apply to: underground mining areas@ dusts of explosives that do not require atmospheric oxygen for combustion@ pyrophoric substances.

Explosive atmospheres - Part 17: Electrical installations inspection and maintenance

ICS
29.260.20
CCS
K35
发布
2013-11
实施
2013-11-21

Explosive atmospheres - Part 32-1: Electrostatic hazards - Guidance

ICS
29.260.20;35.240.50
CCS
K35
发布
2013-08
实施

National Differences For UL 60079-0 Explosive atmospheres - Part 0: Equipment - General requirements (Sixth Edition; Reprint with revisions through and including October 20@ 2017)

ICS
CCS
K35
发布
2013-07-26
实施

UL Standard for Safety Explosive atmospheres �C Part 0: Equipment �C General requirements (Sixth Edition; Reprint with revisions through and including October 20@ 2017)

ICS
29.260.20
CCS
K35
发布
2013-07-26
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号