K48 绝缘子 标准查询与下载



共找到 589 条与 绝缘子 相关的标准,共 40

Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1000 V - Definitions, test methods, acceptance criteria and design recommendations (IEC 61462:2007); German version EN 6

ICS
29.080.10
CCS
K48
发布
2008-06
实施
2008-06-01

This Technical Specification applies to - ceramic and glass hollow insulators intended for general use in electrical equipment; - ceramic hollow insulators intended for use with a permanent gas pressure in switchgear and controlgear. They are intended for indoor and outdoor use in electrical equipment, operating on alternating current with a rated voltage greater than 1 000 V and a frequency not greater than 100 Hz or for use in direct current equipment with a rated voltage greater than 1 500 V. This specification specifies the dimensional and mechanical characteristics of the hollow insulator, which are essential for interchangeability of the hollow insulator of the same type. It is not the object of this specification to prescribe electrical characteristics because they are dependent on the apparatus of which the hollow insulator ultimately forms a part. However, standard lightning impulse withstand voltage which is provided in IEC 60071-1 is described only for reference for classification purpose. This specification applies to hollow insulators for use in electrical equipment in clean areas or lightly polluted areas, where seismic qualification is not required. For use in areas characterised by heavy pollution levels and for other particular or extreme environmental conditions such as seismic force, it may be necessary for certain dimensions to be changed. The hollow insulators covered by this specification are: a) straight type hollow insulators with metal fittings on both ends; b) taper type hollow insulators with metal fittings on both ends; c) straight type hollow insulators without metal fittings; d) taper type hollow insulators without metal fittings. The hollow insulators are intended for use in electrical equipment, for example: - circuit-breakers; - instrument transformers; - surge arresters; - bushings; - cable sealing ends; - switch-disconnectors; - disconnectors; - earthing switches; - capacitors. There may be some cases that hollow insulators whose design can strongly be influenced by other components of specific equipment, for example, active parts of circuit-breakers. For such cases, the hollow insulators can be separately designed, depending on respective requirements of such equipment and not be covered by this specification. NOTE 1 Hollow insulators not prescribed in this specification can also be applied to electrical equipment, depending on specific requirements of the equipment. However, if similar insulators are available in this specification, it is preferable to apply them. NOTE 2 For general recommendations for design and tests of the hollow insulators, see IEC 62155 NOTE 3 For characteristics of hollow insulators for use in polluted areas, reference can be made to IEC 60815- 1and IEC 60815-2.

Characteristics of hollow pressurised and unpressurised ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V

ICS
29.080.10
CCS
K48
发布
2008-05
实施

This International Standard applies to composite suspension/tension insulators consisting of a load-bearing cylindrical insulating solid core consisting of fibres - usually glass - in a resin- based matrix, a housing (outside the insulating core) made of polymeric material and end fittings permanently attached to the insulating core. Composite insulators covered by this standard are intended for use as suspension/tension line insulators, but it should be noted that these insulators can occasionally be subjected to compression or bending, for example when used as phase-spacers. This standard can be applied in part to hybrid composite insulators where the core is made of a homogeneous material (porcelain, resin), see Clause 8. The object of this standard is to - define the terms used, - prescribe test methods, - prescribe acceptance criteria. This standard does not include requirements dealing with the choice of insulators for specific operating conditions.

Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1000 V - Definitions, test methods and acceptance criteria

ICS
29.080.10
CCS
K48
发布
2008-05
实施
2008-05-31

This International Standard applies to composite line post insulators consisting of a load- bearing cylindrical insulating solid core consisting of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of polymeric material and end fittings permanently attached to the insulating core. Composite line post insulators covered by this standard are subjected to cantilever, tensile and compressive loads, when supporting the line conductors. They are intended for use on a.c. overhead lines with a rated voltage greater than 1 000 V and a frequency not greater than 100 Hz. The object of this standard is - to define the terms used, - to prescribe test methods, - to prescribe acceptance or failure criteria. This standard does not include requirements dealing with the choice of insulators for specific operating conditions.

Insulators for overhead lines - Composite line post insulators for a.c. systems with a nominal voltage greater than 1000 V - Definitions, test methods and acceptance criteria

ICS
29.080.10
CCS
K48
发布
2008-05
实施
2008-06-03

Ceramic support insulators for voltage over 1000 V. General specifications

ICS
29.080.10
CCS
K48
发布
2008
实施
2010-01-01

This International Standard applies to composite hollow insulators consisting of a load-bearing insulating tube made of resin impregnated fibres, a housing (outside the insulating tube) made of elastomeric material (for example silicone or ethylene-propylene) and metal fixing devices at the ends of the insulating tube. Composite hollow insulators as defined in this standard are intended for general use (unpressurized) or for use with a permanent gas pressure (pressurized). They are intended for use in both outdoor and indoor electrical equipment operating on alternating current with a rated voltage greater than 1 000 V and a frequency not greater than 100 Hz or for use in direct current equipment with a rated voltage greater than 1 500 V. This standard does not prescribe impulse voltage or power frequency voltage type tests, nor does it prescribe pollution tests because the withstand voltages are not characteristics of the hollow insulator itself, but of the apparatus of which it ultimately forms a part. All the tests in this standard, apart from the thermal-mechanical test, are performed at normal ambient temperature. This standard does not prescribe tests that may be characteristic of the apparatus of which the hollow insulator ultimately forms a part. Further technical input is required in this area.

Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1000 V. Definitions, test methods, acceptance criteria and design recommendations

ICS
29.080.10
CCS
K48
发布
2007-11-30
实施
2007-11-30

This standard is about Composite string insulator units for overhead lines with a nominal voltage greater than 1000 V - Part 1: Standard strength classes and end fittings; Corrigendum 1

Composite string insulator units for overhead lines with a nominal voltage greater than 1000 V - Part 1: Standard strength classes and end fittings; Corrigendum 1

ICS
29.080.10
CCS
K48
发布
2007-11
实施

IEC/TS 62371, Ed. 1.0: Characteristics of hollow pressurised and unpressurised ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V

ICS
29.080.10
CCS
K48
发布
2007-10
实施

Applies to composite hollow insulators consisting of a load-bearing insulating tube made of resin impregnated fibres, a housing (outside the insulating tube) made of elastomeric material (for example silicone or ethylene-propylene) and metal fixing devic

Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations

ICS
29.080.10
CCS
K48
发布
2007-09-28
实施

International Electrotechnical Vocabulary - Part 471 : insulators.

ICS
01.040.29;29.080.10
CCS
K48
发布
2007-08-01
实施
2007-08-18

Polymeric insulators for indoor and outdoor use with a nominal voltage 1000 V - General definitions, test methods and acceptance criteria (IEC 62217:2005); German version EN 62217:2006, Corrigenda to DIN EN 62217 (VDE 0441-1000):2006-11; German v

ICS
01.040.29;29.080.10
CCS
K48
发布
2007-08
实施

本标准规定了低压绝缘子瓷件的技术要求、试验、包装和标志的一般要求。 本标准适用于直流电压低于1000V的或交流电压低于1000V、频率不超过lOOHz的架空电力线路、电气装置和设备上使用的绝缘子瓷件。 本标准不适用于在有破坏瓷及釉的介质(气体或液体)中工作的瓷件。

Technical specifications of porcelain element for low voltage insulators

ICS
29.080.10
CCS
K48
发布
2007-07-27
实施
2006-10-11

本标准规定了交流系统中运行的电力设备和装置上的户内和户外复合支柱绝缘子的定义、技术要求、标志和试验分类及检验规则。 本标准适用于标称电压1kV~252kV、频率不超过50Hz的交流系统中运行的电力设备和装置上的户内和户外棒形支柱复合绝缘子(简称绝缘子)。安装地点的海拔高度为1000m及以下,环境温度在-40℃~+40℃之间。 本标准不包含特殊运行条件下选用绝缘子的要求。

Composite post insulators for a.c. with a nominal voltage greater than 1000V.definitions,test methods and acceptance criteria

ICS
29.080.10
CCS
K48
发布
2007-07-20
实施
2007-12-01

IEC 60815-1 TS, Ed. 1.0: Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles

ICS
29.080.10;29.260.99
CCS
K48
发布
2007-07
实施

IEC 60815-3-TS, Ed. 1.0: Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part §: Polymer insulators for a.c. systems

ICS
29.080.10;29.260.99
CCS
K48
发布
2007-07
实施

Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria (IEC 62231:2006); German version EN 62231:2006

ICS
29.080.10
CCS
K48
发布
2007-07
实施
2007-07-01

IEC 60815-2-TS, Ed. 1.0: Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems

ICS
29.080.10;29.260.99
CCS
K48
发布
2007-07
实施

This International Standard applies to composite station post insulators consisting of a load bearing cylindrical insulating solid core made of resin impregnated fibres, a housing (outside the insulating solid core) made of elastomer material (e.g. silicone or ethylene-propylene) and end fittings attached to the insulating core. Composite station post insulators covered by this standard are subjected to cantilever, torsion, tension and compression loads. They are intended for substations with a.c. voltages greater than 1 000 V up to 245 kV. The object of this standard is – to define the terms used, – to prescribe test methods, – to prescribe acceptance or failure criteria. This standard does not include requirements dealing with the choice of insulators for specific operating conditions.

Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria

ICS
29.080.10
CCS
K48
发布
2007-05-31
实施
2007-05-31

General Instructions for CSA Standards are now called Updates. Please contact CSA Information Products Sales or visit www.ShopCSA.ca for information about the CSA Standards Update Service.

Extruded insulating tubes

ICS
CCS
K48
发布
2007-03-01
实施

本标准规定了额定电压1kV(Um=1.2kV)到10kV(Um=12kV)纸绝缘电力电缆用瓷套式终端的产品标记和代号、技术要求、试验方法、检验规则、标志、包装、运输和贮存。 本标准适用于额定电压1kV(Um=1.2kV)至10kV(Um=12kV)纸绝缘电力电缆用瓷套式户内终端和户外终端,使用条件符合IEC 60055-1-1997中22.2和22.3规定。

Porcelain bushing terminations for paper insulation power cables with rated voltages from 1kV(Um=1.2kV) up to 10kV(Um=12kV)

ICS
29.035.30
CCS
K48
发布
2007-02-01
实施
2007-02-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved