K71 电光源产品 标准查询与下载



共找到 1063 条与 电光源产品 相关的标准,共 71

This standard is Luminaires - Part 2-23: Particular requirements - Extra low voltage lighting systems for filament lamps; Amendment 1.

Luminaires - Part 2-23: Particular requirements - Extra low voltage lighting systems for filament lamps

ICS
29.140.40
CCS
K71
发布
2000-05
实施

For lamps for general lighting purposes of all groups having Fa6 , Fa8, G5, G13 and R17d caps.

Double-capped fluorescent lamps - Safety specifications

ICS
29.140.30
CCS
K71
发布
2000-04-15
实施
2000-04-15

Double-capped fluorescent lamps - Safety specifications

ICS
29.140.30
CCS
K71
发布
2000-04-15
实施
2000-04-15

This International Standard specifies the safety requirements for single-capped fluorescent lamps for general lighting purposes of all groups having 2G7, 2GX7, GR8, 2G10, G10q, GR10q, GX10q, GY10q, 2G11, G23, GX23, G24, GX24 and GX32 caps. It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given in this standard. NOTE - Compliance with this standard concerns only safety criteria and does not take into account the performance of single-capped fluorescent lamps for general lighting purposes with respect to luminous flux, colour, starting and operational characteristics. For this information, readers are referred to IEC 60901.

Single-capped fluorescent lamps. Safety specifications

ICS
29.140.30
CCS
K71
发布
2000-04-15
实施
2000-04-15

Specifies requirements for luminaires with built-in transformers or convertors for filament lamps, with supply voltages and output voltages not exceeding 1 000 V for class I and class II luminaires and 250 V for class 0 luminaires.

Luminaires Part 2: Particular requirements Section 6: Luminaires with built-in transformers or convertors for filament lamps

ICS
29.140.40
CCS
K71
发布
2000-04-07
实施

This International Standard specifies the performance requirements for single-capped fluorescent lamps for general lighting service. The requirements of this standard relate only to type testing. Conditions of compliance, including methods of statistical assessment, are under consideration. The following lamp types and modes of operation with external ballasts are included: a) lamps operated with an internal means of starting, having preheated cathodes, for oper-ation on a.c. mains frequencies; b) lamps operated with an external means of starting, having preheated cathodes, for operation on a.c. mains frequencies with the use of a starter, and additionally operating on high frequency; c) lamps operated with an external means of starting, having preheated cathodes, for oper-ation on a.c. mains frequencies without the use of a starter (starterless), and additionally operating on high frequency; d) lamps operated with an external means of starting, having preheated cathodes, for oper-ation on high frequency; e) lamps operated with an external means of starting, having non-preheated cathodes, for operation on high frequency.

Single-capped fluorescent lamps - Performance specifications; Amendment 2

ICS
29.140.30
CCS
K71
发布
2000-04
实施
2004-06-09

High-pressure sodium vapour lamps

ICS
29.140.30
CCS
K71
发布
2000-03-20
实施

MS 18002B remains inactive for new design, however, the document is valid for acthewhen needed.

LAMP INCANDESCENT-SEALED BEAM, PAR 36 FOG LAMP 2 SCREW TERMINAL TYPE

ICS
29.140.20
CCS
K71
发布
2000-01-10
实施

The document deals with metal halide lamps with spectral energy distribution similar to natural light for sports lighting.

Metal halide lamps with spectral energy distribution similar to natural light - Part 2: Sports lighting

ICS
29.140.30
CCS
K71
发布
2000-01
实施
2000-01-01

This is Amendment 1 to IEC 60081-2000 (Double-capped fluorescent lamps -Performance specifications)

Double-capped fluorescent lamps - Performance specifications; Amendment 1

ICS
29.140.30
CCS
K71
发布
2000-01
实施
2018-06-13

Measures sources for the purpose of hazard evaluation for photobiological safety of lamps and lamp systems. The standard is to be used by the radiometrist for guidance regarding special problems related to photobiological hazard measurements. Additionally, specific recommendations are included to provide consistency and to reduce test design time and effort.

Recommended Practice on Photobiological Safety for Lamps and Lamp Systems – Measurement Techniques

ICS
29.140.01;13.280;17.240
CCS
K71
发布
2000
实施

This part of IEC 60432 specifies the safety and the related interchangeability requirements of tungsten halogen lamps for general lighting service. It covers those tungsten halogen lamps that are used as direct replacements for conventional tungsten filament lamps as well as new tungsten halogen lamps which have no correspondence in IEC 60432-1, but for which the safety and interchangeability requirements are treated by this standard in conjunction with IEC 60432-1. These tungsten halogen lamps have the following characteristics: - rated wattage up to and including 250 W; - rated voltage of 50 V to 250 V inclusive; - caps B15d, B22d, E12, E14, E17, E26, E26d, E26/50×39, E27 or E27/51×39. Lamps complying with this standard are self-shielded, but need not be marked with a special symbol. As they are direct replacements for conventional tungsten filament lamps, there will be no corresponding luminaire marking. NOTE 1 There is no implication that a tungsten halogen lamp used as a substitute for an incandescent tungsten filament lamp would use the same bulb shape as the original incandescent lamp. NOTE 2 There are two variations of E26 caps which are not fully compatible: E26/24 caps used in North America and E26/25 caps used in Japan. NOTE 3 Self-shielded lamps are lamps for which the luminaire needs no protective shield.

Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes

ICS
29.140.20
CCS
K71
发布
1999-10
实施
2005-05-16

Corrigendum to DIN VDE 0711-217 (VDE 0711 Teil 217):1992-07

ICS
97.200.10;29.140.40
CCS
K71
发布
1999-10
实施

This International Standard specifies the safety requirements for discharge lamps (excluding fluorescent lamps) for general lighting purposes. This International Standard is applicable to low-pressure sodium vapour lamps and to high-intensity discharge (HID) lamps, i.e. high-pressure mercury vapour lamps (including blended lamps), high-pressure sodium vapour lamps and metal halide lamps. It applies to single- and double-capped lamps, having caps as listed in annex A. NOTE This standard only concerns safety criteria and does not take into account performance. The performance standards IEC 60188, IEC 60192, IEC 60662, IEC 61167 and IEC 61549 should be referred to for such characteristics. It may be expected that lamps which comply with this standard will operate safely at supply voltages between 90 % and 110 % of rated supply voltage and when operated with a ballast complying with IEC 60922 and IEC 60923, with a starting device complying with IEC 60926 and IEC 60927, and in a luminaire complying with IEC 60598-1.

Discharge lamps (excluding fluorescent lamps) - Safety specifications

ICS
29.140.30
CCS
K71
发布
1999-10
实施
2003-09-04

This European Standard has been produced under Standardization Mandate M/202 in response to the European Commission Directive implementing Council Directive 92/75/EEC with regard to energy labelling of household lamps. A method of classification of lamps according to energy efficiency is given in the Directive and is not a part of this standard. This standard specifies the test conditions and method of measurement of luminous flux, lamp wattage and lamp life as given on a label on the lamp packaging, together with a procedure for verification of the declared values. Only those parameters that are specific to the above mentioned Directive are included in this standard. All other parameters are included in the relevant lamp performance standards. Lamps covered by this standard are: —mains voltage tungsten filament lamps; —mains voltage tungsten halogen lamps; —self-ballasted lamps; —double-capped fluorescent lamps; —single-capped fluorescent lamps.

Energy efficiency of electric lamps for household use - Measurement methods

ICS
29.140.20;29.140.30
CCS
K71
发布
1999-08-15
实施
1999-08-15

International Standard IEC 60432-1 specifies the safety and interchangeability requirements of tungsten filament incandescent lamps for general lighting service having: - rated wattage up to and including 200 W; - rated voltage of 50 V to 250 V inclusive; - bulbs of the A, B, C, G, M, P, PS, PAR or R shapes, or other bulb shapes where the lamps are intended to serve the same purpose as lamps with the foregoing bulb shapes; - bulbs with all kinds of finishes; - caps B15d, B22d, E12, E14, E17, E26, E26d, E26/50×39, E27 or E27/51×39. As far as is reasonably practicable, this standard is also applicable to lamps with bulbs and caps other than those mentioned above, but which serve the same purpose. This standard specifies the method a manufacturer should use to show that his product conforms to this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given. This standard is concerned with safety criteria only and does not take into account the performance of tungsten filament lamps with respect to luminous flux, life or power consumption characteristics. Readers should refer to IEC 60064 for such characteristics with respect to types normally used for general lighting service. note: * See IEC 60887 for description of the letter symbols. Associated traditional names are: - Pear shape = A, PS - Mushroom = M - Candle = B, C (in North America) - Round bulb = P - Globular = G - Reflector = R - Parabolic reflector = PAR ** There are two variations of E26 caps which are not fully compatible. In this standard separate references are made to E26/24 caps used in North America and E26/25 caps used in Japan.

Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes

ICS
29.140.20
CCS
K71
发布
1999-08
实施
2005-05-16

This International Standard comprises maximum lamp outlines for incandescent lamps (including tungsten-halogen lamps).

Maximum lamp outlines for incandescent lamps

ICS
29.140.20
CCS
K71
发布
1999-07-15
实施
1999-07-15

This International Standard comprises maximum lamp outlines for incandescent lamps (including tungsten-halogen lamps).

Maximum lamp outlines for incandescent lamps

ICS
29.140.20
CCS
K71
发布
1999-07-15
实施
1999-07-15

本标准规定了飞机灯泡的型号、主要尺寸、灯头型号和基本参数、技术要求、试验方法、检验规则和标志、包装、运输、贮存。 本标准适用于飞机上作照明和信号指示用的小型白炽灯泡.

Aircraft bulbs

ICS
29.140
CCS
K71
发布
1999-07-12
实施
2000-01-01

Tungsten halogen lamps (non-vehicle); Amendment 12

ICS
29.140.20
CCS
K71
发布
1999-07
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved