Specifies the safety and interchangeability requirements, together with the test methods and conditions, required to show compliance of tubular fluorescent and other gas-discharge lamps with integrated means for controlling starting and stable operation

Self-ballasted lamps for general lighting services - Safety requirements

ICS
29.140.30
CCS
K72
发布
2006-03-10
实施

This part of IEC 60598 specifies requirements for mains socket-outlet mounted nightlights for use with electric light sources, on supply voltages not exceeding 250 V a.c. 50/60 Hz. It is to be read in conjunction with those sections of Part 1 to which reference is made. NOTE This section does not cover luminaires for surveillance lighting.

Luminaires - Part 2-12: Particular requirements - Mains socket-outlet mounted nightlights

ICS
29.140.40
CCS
K72
发布
2006-03
实施
2006-03-15

この規格は,白熱電球(ハロゲン電球を含む。),蛍光ランプ,HIDランプ及び低圧ナトリウムランプを光源とする定格電圧が交流600V以下の一般用照明器具について,基本的な事項について規定する。

Luminaires -- Part 3: General requirements for performance

ICS
29.140.40
CCS
K72
发布
2006-02-20
实施

この規格は,道路照明器具のうち電源電圧が交流I000V以下のHIDランプ及び低圧ナトリウムランプを用い,6m以上の高さに取り付け,主に自動車交通の用に供する道路の照明に使用する照明器具について規定する。

Luminaires for road lighting

ICS
93.080.40
CCS
K72
发布
2006-02-20
实施

この規格は,定格システム出力20kW未満の系統連系(停電時などに一時的に自立運転可能なシステムも含む。)を行う住宅用太陽光発電システムの電気系に関し,システムとしての安全設計を主体に,各要素機器及びそれらの設置,接続配線などに必要な安全条件にーフいて規定する。

Standards for safety design of electrical circuit in photovoltaic power generating systems for residential use

ICS
27.160;29.020
CCS
K72
发布
2006-02-20
实施

Double-capped fluorescent lamps - Performance specifications.

ICS
29.140.30
CCS
K72
发布
2006-02-01
实施
2006-02-20

This European Standard specifies requirements for roof lights made of plastic materials (e.g. GF-UP, PC, PMMA, PVC) with and without upstands made of e.g. GF-UP, PVC, steel, aluminium or wood for installation in roofs. These roof lights serve the purpose of lighting by means of daylight and of ventilating interior spaces by means of opening devices. This European Standard applies to roof lights with a rectangular or circular ground plan (see Figures 1 and 2), with an opening span (width) or diameter not larger than 2,5 m and an opening length not larger than 3,0 m in roof pitches up to 25°. This document does not cover roof lights which contribute to the load-bearing or stiffness of the roof itself. This European Standard applies to roof lights without upstand and to roof lights, where a single manufacturer provides all components of the roof light with upstand, which are bought in a single purchase. The possible additional functions of smoke and heat ventilation in case of fire, and/or roof access, are outside the scope of this European Standard. This European Standard does not include calculation with regard to construction, design requirements and installation techniques. NOTE Guidelines for safety, application, use and maintenance of individual roof lights are presented in Annex A.

Prefabricated accessories for roofing - Individual roof lights of plastics - Product specification and test methods

ICS
91.060.20
CCS
K72
发布
2006-01-25
实施
2006-01-25

This is Amendment 2 to IEC 61347-2-3-2000 (Lamp controlgear- Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps)

Lamp controlgear - Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps; Amendment 2

ICS
29.140.99
CCS
K72
发布
2006-01
实施
2011-05-23

Covers emergency lighting and power equipment for use in unclassified locations and intended for connection to branch circuits of 600 volts or less. Such equipment is intended to supply automatically illumination or power or both to critical areas and equipment in the event of failure of the normal supply, in accordance with the National Electrical Code, the Life Safety Code, and the International Building Code. Examples include exit signs, emergency luminaires, unit equipment, central station battery banks, and automatic load control relays. Also covers auxiliary lighting and power equipment for use in unclassified locations.

Emergency Lighting and Power Equipment

ICS
91.140.50;91.160.10
CCS
K72
发布
2006
实施

Lighting concepts and design solutions for various health care facilities with focus on patient sensibilities and comfort needs.

Lighting for Hospitals and Health Care Facilities

ICS
91.160.10;11.020
CCS
K72
发布
2006
实施

この規格は,50Hz若しくは60Hzで1000V,又は直流1000Vを超えない入力電圧に直接接続し,15000V(ピーク)を超えることがない出力電圧で動作する,サイン及び照明放電灯設備において使用する管形冷陰極放電ランプの高周波動作用の電子インバータ及び変換器についての個別要求事項を規定する。

Lamp controlgear -- Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes)

ICS
29.140.99
CCS
K72
发布
2005-12-20
实施

This Standard applies to direct plug-in nightlights not exceeding 10 W input, for indoor use only, in non-hazardous locations and intended to be used in accordance with the Canadian Electrical Code, Part I, CSA C22.1, and the National Electrical Code, ANSI/NFPA 70. Light source types include incandescent candelabra base lamps, non-replaceable lamps, [fluorescent, neon, or light-emitting diode (LED) type] or electroluminescent panels. 1.2 These requirements cover direct plug in nightlights for insertion into a parallel slot receptacle rated 125 volts maximum. 1.3 These requirements do not cover: (a) cord-connected luminaires; (b) nightlights with more than one receptacle; or (c) direct plug-in devices with other primary functions, such as room deodorizers, insect repellers, or rechargeable flashlights.

Direct plug-in nightlights

ICS
91.160.10
CCS
K72
发布
2005-12-09
实施

This is Amendment 1 to IEC 61347-2-2-2000 (Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down)

Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps; Amendment 1

ICS
29.140.99
CCS
K72
发布
2005-12
实施

Luminaires - Part 2-11 : particular requirements - Aquarium luminaires.

ICS
29.140.40
CCS
K72
发布
2005-11-01
实施
2005-11-20

This document specifies the lighting classes set out in EN 13201-2 and gives guidelines on the application of these classes. It also gives guidelines on the selection of the relevant area to which the lighting classes from EN 13201-2 and the calculation grids and procedure from EN 13201-3 should be applied. This document does not give the criteria on which a decision to light an area can be made, nor on how a lighting installation should be used. This document does not give guidelines on the selection of lighting classes for toll stations, tunnels or canals and locks.

Road lighting - Part 1: Selection of lighting classes; German version CEN/TR 13201-1:2004

ICS
93.080.40
CCS
K72
发布
2005-11
实施

Luminaires - Part 2-10: Particular requirements - Portable luminaires for children (IEC 60598-2-10:2003); German version EN 60598-2-10:2003, Corrigenda to DIN EN 60598-2-10 (VDE 0711-2-10):2004-03

ICS
29.140.40;97.200.50
CCS
K72
发布
2005-11
实施

この規定は,JIS C 7527に規定するシート番号60357-IEC-2155の電球,又は特定の電球名称を使用して規定された低封入圧ハロゲン電球を含めて,電源電圧250V以下で使用する白熱電球用撮影用照明器其(アマチュア用)に対する安全性要求事項について規定する。

Luminaires -- Part 2: Particular requirements for safety -- Section 9: Photo and film luminaires (non-professional)

ICS
29.140.40;37.040.99;37.060.99
CCS
K72
发布
2005-09-20
实施

この規格は,入力電圧が250V以下の白熱電球,蛍光ランプ及びその他放電ランプを使用した,庭園のような場所に用いる可搬形の台座付照明器具及び花壇のような場所に使用する移動灯器具に対する安全性要求事項を規定する。

Luminaires -- Part 2: Particular requirements for safety -- Section 7: Portable luminaires for garden use

ICS
29.140.40
CCS
K72
发布
2005-09-20
实施

Specifies lamps, or information relevant to lamps, not given elsewhere in existing SANS lamp standards.

Miscellaneous lamps

ICS
29.140.20;29.140.30
CCS
K72
发布
2005-09-16
实施

This Standard specifies requirements for miniature halogen and non-halogen lamps with a nominal voltage up to 30 V and a nominal wattage up to 25 W.