K72 一般灯具 标准查询与下载



共找到 737 条与 一般灯具 相关的标准,共 50

This Part 1 of International Standard IEC 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classificatio

Luminaires - Part 1: General requirements and tests

ICS
29.140.40
CCS
K72
发布
2003-10
实施
2008-04-22

この規格は,JIS C 8105-1第0章の0.1の規定を基に,定格電圧が250V以下の白熱電球,蛍光ランプ及ぴその他の放電ランプを光源とする一般照明用移動灯器具について規定する。

Luminaires -- Part 2: Particular requirements for safety -- Section 4: Portable general purpose luminaires

ICS
29.140.40
CCS
K72
发布
2003-09-20
实施

この規格は,電源電圧が1000V以下の白熱電球(ハロゲン電球を合む。),蛍光ランプ及びその他の放電ランプ用の投光器に適用する。

Luminaires -- Part 2: Particular requirements for safety -- Section 5: Floodlights

ICS
13.260;29.140.40
CCS
K72
发布
2003-09-20
实施

この規格は,入力電圧が1000V以下の白熱電球,蛍光ランプ及びその他放電ランプ用の一般用埋込み形照明器具の要求事項を規定する。

Luminaires -- Part 2: Particular requirements for safety -- Section 2: Recessed luminaires

ICS
29.140.40;91.160.01
CCS
K72
发布
2003-09-20
实施

Luminaires -- Part 2: Particular requirements for safety -- Section 3: Luminaires for road and street lighting

ICS
29.140.40;93.080.40
CCS
K72
发布
2003-09-20
实施

This Standard applies to direct plug-in nightlights not exceeding 10 W input, for indoor use only, in non-hazardous locations and intended to be used in accordance with the Canadian Electrical Code, Part I, CSA C22.1, and the National Electrical Code, ANSI/NFPA 70. Light source types include incandescent candelabra base lamps, non-replaceable lamps, [fluorescent, neon, or light-emitting diode (LED) type] or electroluminescent panels. 1.2 These requirements cover direct plug in nightlights for insertion into a parallel slot receptacle rated 125 volts maximum. 1.3 These requirements do not cover: (a) cord-connected luminaires; (b) nightlights with more than one receptacle; or (c) direct plug-in devices with other primary functions, such as room deodorizers, insect repellers, or rechargeable flashlights.

(DRAFT) UL Standard for Safety Direct Plug-In Nightlights Proposed Third Edition; Comments due by 10/20/2003

ICS
91.160.10
CCS
K72
发布
2003-09-02
实施

Lamp controlgear - Part 1: General and safety requirements; Amendment 1

ICS
29.140.99
CCS
K72
发布
2003-09
实施

This standard is about Lamp controlgear - Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps); Amendment 1

Lamp controlgear - Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps); Amendment 1

ICS
29.140.99
CCS
K72
发布
2003-09
实施

This International Standard specifies lamps, or information relevant to lamps, not given elsewhere in existing IEC lamp standards. It covers both safety and performance aspects.

Miscellaneous lamps

ICS
29.140.20;29.140.30
CCS
K72
发布
2003-07-24
实施
2003-07-24

Miscellaneous lamps

ICS
CCS
K72
发布
2003-07-24
实施
2003-07-24

This International Standard specifies lamps, or information relevant to lamps, not given elsewhere in existing IEC lamp standards. It covers both safety and performance aspects. NOTE For reasons of flexibility the information in this loose-leaf publication is given in data sheet format.

Miscellaneous lamps

ICS
29.140.20;29.140.30
CCS
K72
发布
2003-07-24
实施
2003-07-24

This European Standard specifies the requirements for the verification of the design of lighting columns by calculation. It applies to post top columns not exceeding 20 m height for post top lanterns and to lighting columns with brackets not exceeding 18 m height for side entry lanterns. The calculations used in this standard are based on limit state principles, where the effects of factored loads are compared with the relevant resistance of the structure. Two limit states are considered: a) the ultimate limit state, which corresponds to the load-carrying capacity of the lighting column; b) the serviceability limit state, which relates to the deflection of the lighting column in service. NOTE In following this approach, simplifications appropriate to lighting columns have been adopted, These are: 1) the calculations are applicable to circular and regular octagonal cross-sections; 2) the number of separate partial safety factors have been reduced to a minimum; 3) serviceability partial safety factors have a value equal to unity. The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this standard. This standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not included, this group of lighting columns will have additional requirements (see prEN 40-2).

Lighting columns - Design and verification - Verification by calculation

ICS
93.080.40
CCS
K72
发布
2003-07-02
实施
2003-07-02

This standard is Luminaires - Part 2: Particular requirements - Section 20: Lighting chains; Interpretation Sheet 3.

Luminaires - Part 2: Particular requirements - Section 20: Lighting chains

ICS
29.140.40
CCS
K72
发布
2003-07
实施

This standard is Luminaires - Part 2: Particular requirements - Section 20: Lighting chains; Interpretation Sheet 2.

Luminaires - Part 2: Particular requirements - Section 20: Lighting chains

ICS
29.140.40
CCS
K72
发布
2003-07
实施

Specifies requirements for luminaires for road, street lighting and other public outdoor lighting applications, tunnel lighting, column-integrated luminaires with a minimum total height above normal ground level of 2,5 m, and for use with electrical ligh

Luminaires Part 2-3: Particular requirements - Luminaires for road and street lighting

ICS
29.140.40;93.080.40
CCS
K72
发布
2003-06-27
实施

The document specifies the performance requirements for fibre reinforced polymer composite lighting columns for which the main intended use is road lighting. It includes materials and test methods. The composite materials considered are those constructed from a fibrous reinforcing material that is suspended in a matrix of resin material. It applies to post top columns not exceeding 20 m height for post top lanterns and columns with brackets not exceeding 18 m height for side entry lanterns.

Lighting columns - Part 7: Requirements for fibre reinforced polymer composite lighting columns; German version EN 40-7:2002

ICS
83.120;93.080.40
CCS
K72
发布
2003-06
实施

Rules for the inspection of portable luminaires for garden use for import and export

ICS
29.140
CCS
K72
发布
2003-05-28
实施
2003-12-01

本标准规定了进出口固定式通用灯具的安全要求和外观,包装检验的抽样,检验及 检验结果的判定。 本标准适用于电源电压不超过 1 000 V ,使用钨丝灯、管形荧光灯及其他气体放电灯等作为光源的 进出口灯具的检验。

Rules for the inspection of fixed general purpose luminaires for import and export

ICS
29.140
CCS
K72
发布
2003-05-28
实施
2003-12-01

本标准规定了进出口嵌人式通用灯具的安全要求和外觀,包裝檢驗的抽樣、檢驗及 检验结果的判定。 本标准适用于电源电压不超过 1 000 V ,使用钨丝灯、管形荧光灯和其他气体放电灯为光源的进出 口戏和人式灯具的检验。

Rules for the inspection of recessed general purpose luminaires for import and export

ICS
29.140
CCS
K72
发布
2003-05-28
实施
2003-12-01

May 1997 Standard NF C17-200 Interpretation Table No. 17-200-F2

ICS
29.260.10;93.080.40
CCS
K72
发布
2003-05-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved