K73 特殊灯具 标准查询与下载



共找到 556 条与 特殊灯具 相关的标准,共 38

This standard applies for safety regulations for tripods (stands) in the technical field of stages and studios for film and television.

Projectors for film, television, stages and photography - Part 27: Hand-operated stands, safety requirements and testing

ICS
97.200.10
CCS
K73
发布
2006-01
实施

MS24345G is inactive for new design and is no longer used, except for replacement purposes.

BASE PLATE ASSEMBLY, RUNWAY MARKER LAMP

ICS
29.140.40
CCS
K73
发布
2006
实施

1.1 This specification provides the requirements for light source products intended for excitation of fluorescent materials used as a system for detection of defects in industrial coatings. This includes the examination of both longer wavelength fluorescing primer coatings as well as non-fluorescent top coatings.1.2 This specification establishes the radiometric requirements of the light source product in terms of required wavelength range and minimum irradiance.1.3 This specification establishes safety requirements for the light source product necessary to ensure the product will not pose a threat to visual health.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Light Source Products for Inspection of Fluorescent Coatings

ICS
25.220.01 (Surface treatment and coating in genera
CCS
K73
发布
2006
实施

1.1 The function of the illuminator is to provide sufficient illumination and viewing capabilities for the purpose of identification and interpretation of radiographic images. This specification provides the recommended minimum requirements for Industrial Radiographic Illuminators used for viewing industrial radiographic films using transmitted light sources.1.2 The illuminator has to ensure the same safety for personnel, or users of any electric apparatus, as specified by electrical standards applicable in the country in which the illuminator is used.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.3 Values stated in SI units are to be regarded as the standard. The values given in parenthesis are provided for information only.

Standard Specification for Illuminators Used for Viewing Industrial Radiographs

ICS
19.100 (Non-destructive testing)
CCS
K73
发布
2006
实施

This recirculation proposal provides revisions to the UL 588 proposal dated 3-10-06. The revisions being proposed are based on comments received during the ballot and review of the proposal document. The following topics are being recirculated: 2. Revision of individual flashing lamp requirements to allow alternative constructions that do not permit an individual-flashing lamp to be installed in a lampholder intended for a steady-illuminating lamp in the same lighting string 8. Requirements for lighting sculptures consisting of multiple sections 12. Increased current rating for motorized tree stands and lighting sculptures. 14. Addition of requirements for lighting strings intended for use on a patio umbrella 17. Revision to allow a light string that operates without bulbs in the sockets 18. Addition of alternate rain test for series connected lighting strings 19. Clarification of lamp replacement instructions 20. Miscellaneous corrections and clarifications.

Standard for Safety for Seasonal and Holiday Decorative Products

ICS
29.140.40
CCS
K73
发布
2006
实施

이 규격은 항공용 필라멘트 램프의 품질과 호환성을 보장하는 기술적인 요구 사항을 언급 한다

Aircraft electrical filament lamps

ICS
29.140.30
CCS
K73
发布
2005-12-28
实施
2005-12-28

To be read in conjunction with BS EN 1838:1999, BS EN 50172:2004

Emergency lighting. Code of practice for the emergency lighting of premises

ICS
13.200;29.120.99;91.160.10
CCS
K73
发布
2005-12-01
实施
2005-12-01

本部分规定了双端荧光灯用照明灯具(以下简称“灯具”)的技术要求、试验方法、检验规则、标志、包装、运输和贮存等。 本部分适用于铁道客车车厢双端荧光灯用照明灯具 。

Lamp for railway passenger car.Part 3: appliances for double-capped fluorescent lamps

ICS
45.060.20
CCS
K73
发布
2005-08-19
实施
2006-01-01

Entertainment technology, stage lighting - Two-pole special male plug with protective contact, 63 A, ~ 250 V, 50/60 Hz

ICS
29.120.30;97.200.10
CCS
K73
发布
2005-08
实施

The document is the eighth edition of UL 879, the Standard for Electric Sign Components, formerly the Standard for Electrode Receptacles for Gas-Tube Signs. 1.1.1 These requirements cover components for use in signs and outline lighting systems intended for installation in accordance with the National Electrical Code, NFPA 70. Components covered by this standard include the types specified in 1.1.2, including electromechanical components that convey a message or outline the structural features of a building by electronically directing or rechanneling available light from other sources and involving all forms of illumination such as: fluorescent lighting, high intensity discharge (HID) lighting, neon lighting, cold cathode lighting, light emitting diodes (LED), and electroluminescent lighting. 1.1.2 Examples of components intended to be covered by this standard include: a) Materials used in signs and outline lighting such as structural panels, sign face materials, switch enclosures, sign frames, electrical enclosures, accessibility barriers, trim caps, water shields, coatings and lubricants, components related to material installation and the like. b) Electrical components relating to illumination circuits operating at 1000 volts and above such as electrode receptacles, lampholders, neon electrode enclosures, GTO sleeving, integrally sleeved GTO cable, GTO cable splice enclosures and insulating devices. c) Electromechanical and electronic equipment for use in signs such as LED units, LED power sources, sign flashers, animating equipment, scrolling units, and sign rotating equipment. 1.1.3 This standard does not cover components covered by another standard, unless there are additional considerations that need to be addressed when the component is for use in signs and outline lighting. 1.1.4 These requirements do not cover: Christmas Tree and Other Decorative Lighting Devices, Exit Lighting and Luminaires and Low Level Path Marking and Lighting Systems Fluorescent Ballasts, Fluorescent Lampholders, Incandescent luminaires, GTO Cable, High Intensity Discharge Ballasts, HID lighting luminaires, Incandescent Lampholders, Incandescent lighting, Luminaires of any kind, Low Voltage Landscape Lighting Systems, Low Voltage Lighting Fixtures for Use in Recreational Vehicles, Low Voltage Marine Lighting, Marine Navigational Lights, Marine Type Fixtures, Neon Transformers and Power Supplies, Portable Electric Displays, Portable Handlamps, Portable lamps and Cabinet Lamps, Portable Luminaires, Portable Sun/Heat Lamps, Stage and Studio Luminaires, Self-ballasted fluorescent lamps, Temporary Lighting Strings, Track lighting fixtures.

Electric sign components

ICS
29.140.99
CCS
K73
发布
2005-06-06
实施

The activities above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http://assist.daps.dla.mil

LIGHT, CHEMILUMINESCENT, 6 IN - 5 IN - C

ICS
29.140.40
CCS
K73
发布
2005-05-27
实施

This proposal includes substantive changes to requirements originally balloted to the STP on July 1, 2005.

Standard for Safety for Portable Electric Luminaires

ICS
29.140.40
CCS
K73
发布
2005
实施

This is Amendment 1 to IEC 60598-2-25-2004 (Luminaires Part 2-22: Particular requirements-Luminaires for use inn clinical areas of hospitals and health care bulidings)

Amendment 1 - Luminaires - Part 2-25: Particular requirements - Luminaires for use in clinical areas of hospitals and health care buildings

ICS
29.140.40
CCS
K73
发布
2004-09-01
实施
2004-10-01

This bulletin contains the report of the STP meeting held April 14, 2004 and contains the STP's disposition of the comments from the ballot of UL 1574, bulletin dated December 12, 2003, and proposes substantive changes in requirements based on these comments.

Track Lighting System

ICS
29.140.50
CCS
K73
发布
2004-08-30
实施

The General Services Administration has authorized the use of this commercial item description as a replacement for Military Specifications MIL-V-16720E and MIL-V-16721D which are cancelled.

MARKER LIGHT, PERSONAL DISTRESS

ICS
29.140.40
CCS
K73
发布
2004-07-07
实施

Luminaires - Part 2-10 : particular requirements - Portable luminaires for children.

ICS
29.140.40;97.190
CCS
K73
发布
2004-01-01
实施
2004-01-20

The activities above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http://assist.daps.dla.mil.

LANTERN, ELECTRIC, HAND, SAFETY [Superseded: DLA MIL-L-18937 D CANC NOTICE 1, DLA MIL-L-18937 D, DLA MIL-L-18937 C, DLA MIL-L-18937 B INT AMD 1, DLA MIL-L-18937 B]

ICS
29.140.40
CCS
K73
发布
2004
实施

Covers electric lighting fixtures for installation and use in hazardous (classified) locations, Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; and Class III, Divisions 1 and 2, in accordance with the National Electrical Code, ANSI/NFPA 70. UL 844 also covers explosion-proof luminaries for installation and use in Class I, Zone 1, Groups IIA, IIB, IIB plus Hydrogen, and IIC hazardous (classified) locations.

Electric Lighting Fixtures for Use in Hazardous (Classified) Locations

ICS
29.140.40
CCS
K73
发布
2004
实施

1 This part of IEC 61534 specifies general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz/60 Hz, with a rated current not exceeding 63 A. These systems are used for distributing electricity in household, commercial and industrial premises. NOTE The extension of the scope to cover d.c. and communication systems is under consideration. 2 Powertrack systems, according to this standard, are intended for use under the following conditions: - an ambient temperature in the range -5℃ to +40 ℃, the average value over a 24 h period not exceeding 35 ℃; - a situation not subject to a source of heat likely to raise temperatures above the limits specified above; - an altitude not exceeding 2 000 m above sea level; - an atmosphere not subject to excessive pollution by smoke, chemical fumes, prolonged periods of high humidity or other abnormal conditions. In locations where special conditions prevail, as in ships, vehicles and the like and in hazardous locations, for instance, where explosions are liable to occur, special constructions may be necessary. This standard does not apply to: - cable trunking systems and cable ducting systems covered by IEC 61084 [8] - busbar trunking systems covered by IEC 60439-2 [5] - electrical supply track systems for luminaires covered by IEC 60570 [6] note:1) Figures in square brackets refer to the bibliography.

Powertrack systems - General requirements

ICS
29.060.10;29.140.50
CCS
K73
发布
2003-10-15
实施
2003-10-15

This standard applies for projectors for film and television studios, stage and photographic use with incandescent lamps with a consumption of 0,25 to 20 kW and for projectors with metal halide lamps with a consumption of 0,125 to 18 kW.#,,#

Projectors for film and television studios, stage and photographic use - Part 1: Projectors for incandescent lamps, consumption 0,25 kW to 20 kW and for metal halide lamps, consumption 0,125 kW to 18 kW; Optical systems, equipment

ICS
97.200.10
CCS
K73
发布
2003-08
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号