K74 灯具附件 标准查询与下载



共找到 1112 条与 灯具附件 相关的标准,共 75

JIS C 7709-3:2004の一部を,次のように改正する。

Lamp caps and holders together with gauges for the control of interchangeability and safety Part 3: Gauges (Amendment 2)

ICS
29.140.10
CCS
K74
发布
2007-06-20
实施

JIS C 7709-2:2004の一部を,次のように改正する。

Lamp caps and holders together with gauges for the control of interchangeability and safety Part 2: Lampholders (Amendment 2)

ICS
29.140.10
CCS
K74
发布
2007-06-20
实施

JIS C 7709-0:2004の一部を,次のように改正する。

Lamp caps and holders together with gauges for the control of interchangeability and safety Part 0: General information (Amendment 2)

ICS
29.140.10
CCS
K74
发布
2007-06-20
实施

Lamp controlgear - Part 2-7: Particular requirements for d.c. supplied electronic ballasts for emergency lighting (IEC 61347-2-7:2006); German version EN 61347-2-7:2006

ICS
29.140.99
CCS
K74
发布
2007-06
实施
2007-06-01

This International Standard specifies performance requirements for starting devices (starters and ignitors) for tubular fluorescent and other discharge lamps for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, which produce starting pulses not greater than 5 kV. This standard is used in conjunction with IEC 61347-1 and IEC 61347-2-1. NOTE 1 All glow starters for fluorescent and other discharge lamps including thermal relay/cut-outs will be included in IEC 60155. NOTE 2 There are regional standards regarding the regulation of EMC requirements for end-products like luminaires and independent control gear. In a luminaire, the control gear is dominant in this respect. Control gear, together with other components, should comply with these standards.

Auxiliaries for lamps - Starting devices (other than glow starters) - Performance requirements

ICS
29.140.30;29.140.99
CCS
K74
发布
2007-06
实施
2013-09-18

Decentralized Rural Electrification Systems (DRES) are designed to supply electric power to sites which are not connected to a large interconnected system, or a national grid. As described in the IEC 62257-1, these systems include: • an electrical power production subsystem; • a secondary grid for sharing/distributing this power, when the system is a collective electrification system (microgrid); • a subsystem for utilizing this electrical power as a demand subsystem including the in-house wiring and user's electrical appliances. In many situations, lighting is the most expected application of the rural electrification process and the first application that the users may afford. For a given lighting performance, the electrical characteristics of the lamps may vary, particularly the power factor and the harmonic content. On large grids, the impact of these characteristics is generally not a major issue. In the context of the electrification systems considered in the IEC 62257 series, the main applications are lighting and TV. In these small systems, the power factor and the harmonic content of the supplied appliances have a high impact on the design and the sizing of the production and distribution subsystems as well as on the quality of the service provided. Project implementers cannot afford an over-sizing of any part of the system. For this reason, they have to make sure that the selected appliances have characteristics which do not adversely affect the cost of the equipment necessary to provide the quality of service required by the General Specification of the project. Some relevant products are available on the market (high power factor and low harmonic content).The purpose of this technical specification is to help project implementers to discriminate, in a potential sourcing panel, the models of lamps which could have the lowest impact on the whole system (generation and distribution subsystems). This specification deals with integral compact fluorescent technology lamps: • power less than 60 W; • with an Edison screw E27 or bayonet B22 cap; • with nominal voltage from 100 V to 250 V a.c. IEC 60969 specifies the performance requirements together with the test methods and conditions required to show compliance of tubular fluorescent and other gas-discharge lamps with integrated means for controlling starting and stable operation (self-ballasted lamps) intended for domestic and similar general lighting purpose. This specification must be considered as the reference for the manufacturers. This technical specification proposes comparative tests that could be particularly useful for project implementers to test in laboratories of developing countries the capability of products to be used for their project. The tests can be performed locally, as close as possible of the real site operating conditions. This technical specification does not cover other lamp technologies (e.g. d.c. lamps, leds, etc ) however similar principles can be used for such comparative testing. Additionally some recommendations are suggested in Annex A in order to enhance the performances or effectiveness of the lighting sources using a luminaire. This specification is not a type approval standard. It is a technical specification to be used as guidelines and does not replace any existing IEC standard on lamps.

Recommendations for small renewable energy and hybrid systems for rural electrification - Part 12-1: Selection of self-ballasted (CFL) lamps for rural electrification systems and recommendations for household lighting equipment

ICS
27.160;27.180;27.190;29.140.30;29.140.99
CCS
K74
发布
2007-06
实施

Specifies particular safety requirements for d.c. supplied electronic ballasts for maintained and non-maintained emergency lighting purposes.

Lamp controlgear Part 2-7: Particular requirements for d.c supplied electronic ballasts for emergency lighting

ICS
29.140.99
CCS
K74
发布
2007-05-18
实施
2007-05-18

This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534.

MICROCIRCUIT, HYBRID, LINEAR, 5.2- VOLT, SINGLE CHANNEL, DC-DC CONVERTER

ICS
CCS
K74
发布
2007-04-27
实施

Specifies requirements for ballasts, including reference ballasts, for discharge lamps such as high-pressure mercury vapour lamps, low-pressure sodium vapour lamps, high-pressure sodium vapour lamps and metal-halide lamps.

Ballasts for discharge lamps (excluding tubular fluorescent lamps)

ICS
29.140.30
CCS
K74
发布
2007-04-20
实施

Specifies requirements for ballasts, excluding resistance types, for fluorescent lamps for operation with starters.

Ballasts for fluorescent lamps Part 1: Ballasts for lamps for operation with starters (class A lamps)

ICS
29.140.30
CCS
K74
发布
2007-04-20
实施

This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534.

MICROCIRCUIT, LINEAR, PHASE SHIFT RESONANT CONTROLLER, MONOLITHIC SILICON

ICS
CCS
K74
发布
2007-04-13
实施

Lamp controlgear - Part 2-1: Particular requirements for starting devices (other than glow starters) (IEC 61347 2 1:2000 + A1:2005); German version EN 61347-2-1:2001 + Corrigendum July 2003 + A1:2006, Corrigenda to DIN EN 61347-2-1 (VDE 0712-31):2006-08;

ICS
29.140.99
CCS
K74
发布
2007-04
实施

AC-supplied electronic ballasts for tubular fluorescent lamps - Performance requirements (IEC 60929:2006); German version EN 60929:2006, Corrigenda to DIN EN 60929 (VDE 0712-23):2006-11; CENELEC-Corrigendum December 2006 to EN 60929:2006

ICS
29.140.99
CCS
K74
发布
2007-04
实施

Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements (IEC 60923:2005 + A1:2006); German version EN 60923:2005 + A1:2006

ICS
29.140.99
CCS
K74
发布
2007-04
实施
2007-04-01

Lamp controlgear - Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules (IEC 61347-2-13:2006); German version EN 61347-2-13:2006

ICS
29.140.99
CCS
K74
发布
2007-04
实施
2007-04-01

DC or AC supplied electronic control gear for LED modules - Performance requirements (IEC 62384:2006); German version EN 62384:2006

ICS
29.140.99
CCS
K74
发布
2007-04
实施
2007-04-01

Lamp caps and holders together with gauges for the control of interchangeability and safety – Part 2: Lampholders

Lamp caps and holders together with gauges for the control of interchangeability and safety – Part 2: Lampholders

ICS
CCS
K74
发布
2007-04
实施
2007-04-01

Lamp caps and holders together with gauges for the control of interchangeability and safety – Part 1: Lamp caps

Lamp caps and holders together with gauges for the control of interchangeability and safety – Part 1: Lamp caps

ICS
CCS
K74
发布
2007-04
实施
2007-04-01

Covers performance requirements for ballasts for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps.It covers inductive type ballasts for use on a.c. supplies up to 1 000 V at 50 Hz to 60 Hz associated with discharge lamps, having rated wattage, dimensions and characteristics as specified in the relevant lamp standards.

Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements

ICS
29.140.30
CCS
K74
发布
2007-03-02
实施

This part of IEC 61347 specifies particular safety requirements for d.c. supplied electronic ballasts for maintained and non-maintained emergency lighting purposes. It includes specific requirements for ballasts and control units for luminaires for emergency lighting as specified by IEC 60598-2-22. DC supplied electronic ballasts for emergency lighting may or may not include batteries. This standard also includes operational requirements for ballasts which, in the case of other d.c. supplied electronic ballasts, are regarded as performance requirements. This is because non-operational emergency lighting equipment presents a safety hazard. NOTE Annex J of IEC 61347-2-3 applies to a.c. supplied ballasts (normal operation) that are also suitable for emergency lighting operation from ac/dc supplies.

Lamp controlgear - Part 2-7: Particular requirements for d.c. supplied electronic ballasts for emergency lighting

ICS
29.140.99
CCS
K74
发布
2007-02-28
实施
2007-02-28



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved