K74 灯具附件 标准查询与下载



共找到 1112 条与 灯具附件 相关的标准,共 75

Lamp controlgear - Part 2-13 : particular requirements for d.c. for a.c. supplied electronic controlgear for LED modules.

ICS
29.140.99
CCS
K74
发布
2006-10-01
实施
2006-10-20

This part of IEC 60730 applies to the evaluation of thermal protectors for ballasts for tubular fluorescent lamps. This standard applies to thermal protectors using NTC or PTC thermistors, additional requirements for which are contained in Annex J. Requirements concerning the testing of the combination of ballasts and thermal protectors are given in IEC 61347-1. 1.1.1 This standard applies to the inherent safety, to the operating values, operating times, and operating sequences where such are associated with equipment safety, and to the testing of thermal protectors used to protect ballasts for tubular lamps from overheating. This standard applies to thermal protectors for ballasts within the scope of IEC 61347-2-8. Thermal protectors covered by this standard may be suitable for ballasts for other discharge lamps such as ballasts under the scope of IEC 61347-2-9. Throughout this standard, the word "protector" means "self-resetting thermal ballast protector". 1.1.2 This standard is not applicable to other means used to protect ballasts. 1.1.3 This standard does not apply to a manual device for opening the circuit. This standard applies to protectors for use with ballasts for use on a.c. supplies up to 690 V at 50 Hz or 60 Hz. This standard does not take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer applies.

Automatic electrical controls for household and similar use - Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps

ICS
29.140.99;97.120
CCS
K74
发布
2006-10
实施

This part of IEC 61347 specifies particular safety requirements for electronic controlgear for use on d.c. supplies up to 250 V and a.c. supplies up to 1 000 V at 50 Hz or 60 Hz and at an output frequency which can deviate from the supply frequency, associated with LED modules. Controlgear for LED modules specified in this standard are designed to provide constant voltage or current at SELV or SELV equivalent or higher voltages.Deviations from the pure voltage and current types do not exclude the gear from this standard. The annexes of IEC 61347-1 which are applicable according to this Part 2-13 and using the word “lamp” are understood to also comprise LED modules. Particular requirements for stationary independent SELV controlgear, which are part of the wiring in installations, are given in Annex I. Performance requirements will be covered by IEC 623841. Plug-in controlgear, being part of the luminaire, are covered as for built-in controlgear by the additional requirements of the luminaire standard.

Lamp controlgear - Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules

ICS
29.140.99
CCS
K74
发布
2006-09-29
实施
2006-09-29

Applies to connectors for building-in (including those used for interconnection between LED modules) of miscellaneous types to be used with PCB-based LED modules.

Miscellaneous lampholders Part 2-2: Particular requirements - Connectors for LED-modules

ICS
29.140.10;31.220.10
CCS
K74
发布
2006-09-22
实施
2006-09-22

Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps (IEC 61347-2-8:2000 + A1:2006); German version EN 61347-2-8:2001 + Corrigendum July 2003 + A1:2006

ICS
29.140.99
CCS
K74
发布
2006-09
实施
2006-09-01

This International Standard specifies performance requirements for ballasts for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. Clauses 12 through 15 each detail specific requirements for a particular type of ballast. This standard covers inductive type ballasts for use on a.c. supplies up to 1 000 V at 50 Hz to 60 Hz associated with discharge lamps, having rated wattage, dimensions and characteristics as specified in the relevant IEC lamp standards. NOTE 1 For certain types of discharge lamps an ignitor is required. NOTE 2 Extension of the standard to cover ballasts incorporating, or for use with, series capacitors is under consideration. NOTE 3 The performance requirements of ballasts for tubular fluorescent lamps are covered by IEC 60921. NOTE 4 There are regional standards regarding the regulation of mains current harmonics for end-products such as luminaires and independent control gear. In a luminaire the control gear is dominant in this respect. Control gear, together with other components, should comply with these standards.

Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements

ICS
29.140.99
CCS
K74
发布
2006-09
实施

Lamp controlgear - Part 1: General and safety requirements

ICS
29.140.99
CCS
K74
发布
2006-09
实施

To be read in conjunction with BS EN 60838-1

Miscellaneous lampholders. Particular requirements. Connectors for LED-modules

ICS
29.140.10
CCS
K74
发布
2006-08-31
实施
2006-08-31

Lamp controlgear - Part 2-2 : particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps.

ICS
29.140.99
CCS
K74
发布
2006-08-01
实施
2006-08-20

This part of IEC 61347 specifies particular safety requirements for d.c. supplied electronic ballasts for maintained and non-maintained emergency lighting purposes. It includes specific requirements for ballasts and control units for luminaires for emergency lighting as specified by IEC 60598-2-22. DC supplied electronic ballasts for emergency lighting may or may not include batteries. This standard also includes operational requirements for ballasts which, in the case of other d.c. supplied electronic ballasts, are regarded as performance requirements. This is because non-operational emergency lighting equipment presents a safety hazard. NOTE Annex J of IEC 61347-2-3 applies to a.c. supplied ballasts (normal operation) that are also suitable for emergency lighting operation from ac/dc supplies.

Lamp controlgear - Part 2-7: Particular requirements for d.c. supplied electronic ballasts for emergency lighting

ICS
29.140.99
CCS
K74
发布
2006-08
实施
2011-12-08

Lamp controlgear - Part 2-1: Particular requirements for starting devices (other than glow starters) (IEC 61347-2-1:2000 + A1:2005); German version EN 61347-2-1:2001 + Corrigendum July 2003 + A1:2006

ICS
29.140.99
CCS
K74
发布
2006-08
实施
2006-08-01

Specifies particular safety requirements for electronic step-down convertors for use on d.c. supplies up to 250 V or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz and rated output voltage less than and equal to 50 V r.m.s. at a frequency deviating from t

Lamp controlgear Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps

ICS
29.140.99
CCS
K74
发布
2006-07-28
实施
2006-07-28

States the requirements for both self-healing and non-selfhealing continuously rated a.c. capacitors of up to and including 2,5 kVAr, and not less than 0,1 鍲, having a rated voltage not exceeding 1 000 V, which are intended for use in discharge lamp cir

Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements

ICS
29.140.30
CCS
K74
发布
2006-07-28
实施

Specifies particular safety requirements for starting devices (starters other than glow starters and ignitors) for fluorescent and other discharge lamps for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz which produce starting pulses not greater th

Lamp controlgear Part 2-1: Particular requirements for starting devices (other than glow starters)

ICS
29.140.99
CCS
K74
发布
2006-07-21
实施

この規格は,定格電流が30A以下で,定格電圧が交流277V以下の単相又は交流480V以下の2相若しくは3相50Hz/60Hzの電源用ライティングダクト(PT)システムの一般要求事項及び試験について規定する。

Lighting busways -- Particular safety requirements for power supply use -- Part 1: General requirements

ICS
29.060.10;29.120.20
CCS
K74
发布
2006-07-20
实施

Lamp controlgear - Part 2-2 : particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps.

ICS
29.140.99
CCS
K74
发布
2006-07-01
实施
2006-07-05

This is Amendment 1 to IEC 60923-2005 (Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) -Performance requirements)

Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements - Amendment 1

ICS
29.140.30;29.140.99
CCS
K74
发布
2006-07
实施

To be read in conjunction with BS EN 60598-1

Luminaires. Particular requirements. Mains socket-outlet mounted nightlights

ICS
29.140.40
CCS
K74
发布
2006-06-30
实施
2006-06-30

Lamp controlgear - Part 2-3 : particular requirements for a.c. supplied electronic ballasts for fluorescent lamps.

ICS
29.140.99
CCS
K74
发布
2006-06-01
实施
2006-06-20

AC-Supplied electronic ballasts for tubular fluorescent lamps - Performance requirements.

ICS
29.140.99
CCS
K74
发布
2006-06-01
实施
2006-06-20



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号