共找到 443 条与 电感器、变压器 相关的标准,共 30 页
Voltage transformers; amendment No. 1 to IEC 60186:1987
The General Services Administration has authorized the use of this commercial item description as a replacement for Military Specifications MIL-V-16720E and MIL-V-16721D which are cancelled.
INDUCTOR, (REACTOR) TYPE TF4SX04EB214
This specification lists the ratings, characteristics, inspection requirements and additional information for magnetic oxide cores for broad-baan transformers at assessment levels A and B, which are to be included as the minimum mandatory requirements in any detail specification derived from the correspending sectional specification: IEC Publication 723-3: Inductor and Transformer Cores for Telecommunications. Part 3: Sectional Specification: Magnetic Oxide Cores for Broad-band Transformers. which should also be referred to for guidance on optional requirements.
Harmonized system of quality assessment for electronic components - Inductor and transformer cores for telecommunications - Blank detail specification: magnetic oxide cores for broad-band transformers - Assessment levels A and B
本标准规定了脉宽调制型开关稳压电源中功率输出变压器的计算方法。 本标准适用于脉宽调制型开关电源变压器的设计计算。
Calculating methods for transformers for switched mode power supplies
Instrument transformers for metering service
Instrument transformers for testing purpose and used with general instrument
ELECTRIC TRANSFORMERS. TRANSFORMERS FOR SUPPLY OF CONTROL AND SIGNALLING CIRCUITS. PARTICULAR REQUIREMENTS AND DIMENSIONS.
Fixed inductors for radio interference suppression. Part 2: Sectional specification - Selection of methods of test and general requirements
Characteristics, ratings and inspection requirements. Selects from the generic specification BS 9925-0, and from the basic specification BS 5938-1, the appropriate methods of test to be used in detail specifications derived from it, in accordance with the appropriate blank detail specification.
Harmonized system of quality assessment for electronic components - Inductor and transformer cores for telecommunications - Sectional specification: magnetic oxide cores for broad-band transformers
Outline dimensions and fixing centres for transformers and inductors according to BS 6554-1, for bracket, U-clamp, printed wiring board and frame styles of mounting. The frame style, which is an addition to the text of IEC 60852-1:1986, is preferred in the UK to the bracket style, which has the same outline dimensions.
Outline dimensions of transformers and inductors for use in telecommunication and electronic equipment - Specification for the outline dimensions of transformers and inductors using YEI-1 laminations
Electrotechnical vocabulary. Chapter 321 : instrument transformers.
Irrespective of conductor material and type of insulation.
Winding wires - Basic dimensions - Specification for diameters of conductors for round winding wires
This standard pertains to pulse transformers for use in electronic equipment. For the various types of these transformers, the peak power transmitted ranges from a few milliwatts to kilowatts; and the peak voltage transmitted ranges from a few volts to many kilovolts. The purpose of this standard is to provide a common ground between electronic system engineers and pulse transformer design engineers.
Standard for Pulse Transformers Revision of ANSI/IEEE Std 390-1975 and IEEE Std 391-1976
Specifies requirements for the designation, rating, performance, marking, and testing of current transformers (CTs). Covers aspects common to all CTs (Section 1) and specific requirements for Class M and Class ME measurement CTs (Section 2) and for Class
Current transformers - Measurement and protection
Inspection requirements and tests from which a selection is made when preparing a detail specification for variable r.f. type inductors to be released under the terms of BS 9720 capability approval. Shows required format and lists appropriate ratings and characteristics.
Sectional specification for variable r.f. type inductors of assessed quality for use in electronic equipment for capability approval
Inspection requirements and tests from which a selection is made when preparing a detail specification for inductors to be released under the terms of BS 9720 capability approval. Shows required format and lists appropriate ratings and characteristics. Does not embody an assessment level which is now set by the customer.
Sectional specification for inductors of assessed quality for use in electronic equipment for capability approval
本标准适用于雷达发射机和其它类似设备中带有铁芯的充电电感(CHARGINGINDUCTOR)简称CI。其充电电压为1kV至50kV,重量在数公斤至数百公斤之间。
General specification for high voltage charging inductor for radar (Applicable for certification)
Specifies the outline dimensions of transformers and inductors, using E and I laminations, built for the three most commonly used forms of mounting style, namely bracket mounting, U-clamp mounting and printed wiring board mounting.
Outline dimensions of transformers and inductors for use in telecommunication and electronic equipment. Part 1 : Transformers and inductors using YEI-1 laminations
Shows required format and lists appropriate tests, ratings and characteristics.
Sectional specification for power transformers of assessed quality for use in electronic equipment for capability approval