Q25 绝热、吸声、轻质与防火材料 标准查询与下载



共找到 1626 条与 绝热、吸声、轻质与防火材料 相关的标准,共 109

Thermal insulation products - Product category rules (PCR) for factory made and in-situ formed products for preparing environmental product declarations; German version EN 16783:2017

ICS
91.120.10
CCS
Q25
发布
2017-07
实施

Thermal insulation products. Product category rules (PCR) for factory made and in-situ formed products for preparing environmental product declarations

ICS
91.120.10
CCS
Q25
发布
2017-05-19
实施
2017-05-19

Thermal insulation products for building applications - Instructions for mounting and fixing for determination of the reaction to fire testing of external thermal insulation composite systems (ETICS); German version EN 16724:2015

ICS
91.100.60
CCS
Q25
发布
2017-05
实施

Test method for heat transfer coefficient of aluminum alloy insulating profiles Protected hot box method

ICS
91.100.99
CCS
Q25
发布
2017-04-12
实施
2017-10-01

This European Standard provides the product category rules (PCR) for Type III environmental declarations (as in EN 15804) for factory made and in situ thermal insulation products. Complementary to EN 15804, the PCR described in this European Standard:- specify the declared unit to be used; - define the system boundaries for thermal insulation products; - specify/describe the default scenarios and rules for defining scenarios for certain life cycle information modules. These PCR are intended to be used for cradle to gate, cradle to gate with options or cradle to grave assessment, provided the intention is properly stated in the system boundary description.

Thermal insulation products - Product category rules (PCR) for factory made and in-situ formed products for preparing environmental product declarations

ICS
91.120.10
CCS
Q25
发布
2017-04
实施

本标准规定了模塑聚苯板薄抹灰外墙外保温系统的术语和定义、一般规定、要求、试验方法、检验 规则、产品合格证和使用说明书、包装、运输和贮存。 本标准适用于民用建筑采用的模塑聚苯板薄抹灰外墙外保温系统。

Molded polystyrene board thin plaster exterior wall external thermal insulation system

ICS
ICS 91.100.60
CCS
Q25
发布
2017-03-30
实施
2017-04-30

Thermal insulation materials for buildings

ICS
91.100.60;91.120.10
CCS
Q25
发布
2017-03-21
实施

Preformed cellular plastics thermal insulation materials

ICS
83.140.99;91.100.60
CCS
Q25
发布
2017-03-21
实施

Man made mineral fibre thermal insulation materials

ICS
91.100.60;91.120.10
CCS
Q25
发布
2017-03-21
实施

Phenolic foam board thin plaster exterior wall insulation system material

ICS
91.1
CCS
Q25
发布
2017-03-20
实施
2017-09-01

Plastics - Thermoplastic jackets for insulation products for building equipment and industrial installations - Requirements and test methods; German version EN 15701:2016

ICS
83.140.99
CCS
Q25
发布
2017-02
实施

Thermal insulation products for buildings - Factory made expanded polystyrene (EPS) products - Specification; German version EN 13163:2012+A2:2016

ICS
91.100.60
CCS
Q25
发布
2017-02
实施

Thermal insulation products - Exterior insulation and finish systems - Part 1: Materials and systems

ICS
91.100.60
CCS
Q25
发布
2017-02
实施

Thermal insulation products of buildings. In-situ formed products from loose-fill expanded polystyrene (EPS) beads and bonded expanded polystyrene beads. Specification for the bonded and loose-fill products after installation

ICS
91.100.60
CCS
Q25
发布
2017-01-31
实施
2017-01-31

This European Standard applies to prefabricated walk-in cold room kits and components. It provides test or calculation methods to assess thermal insulation performances under normal end-use conditions. Performance characteristics of walk-in cold rooms are to be assessed in terms of thermal insulating properties, in order to give a basis on which assessing energy consumption related properties of walk-in cold rooms, and of their components. Performance characteristics are to be assessed for every single component of the walk-in cold room, and for the assembled walk-in cold room as a whole. The normal end-use conditions of a walk-in cold room are considered to be:- installation inside an existing building; - not exposed to external weather conditions.

Walk-in cold rooms - Definition@ thermal insulation performance and test methods - Part 1: Prefabricated cold room kits

ICS
97.130.20
CCS
Q25
发布
2017-01
实施

1.1 This specification covers the composition and physical requirements of chemically treated, recycled cellulosic fiber loose-fill type thermal insulation for use in attics or enclosed spaces in housing, and other framed buildings within the ambient temperature range from8201;−45 to 90°C by pneumatic or pouring application. While products that comply with this specification are used in various constructions, they are adaptable primarily, but not exclusively, to wood joist, rafters, and stud construction. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation

ICS
91.100.60
CCS
Q25
发布
2017
实施

1.1 This specification covers the composition and physical properties for perlite thermal insulation board used principally above structural roof decks and as a base for built-up, modified, and elastomeric membrane roofing in building construction. 1.2 When adopted by an authority having jurisdiction, codes that address fire properties in many applications regulate the use of the thermal insulation materials covered by this specification. Fire properties are controlled by job, project, or other specifications where codes or government regulations do not apply. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Perlite Thermal Insulation Board

ICS
91.100.60
CCS
Q25
发布
2017
实施

1.1 This specification covers the composition and physical properties of mineral wool insulation board used above structural roof decks in building construction. The mineral wool roof insulation acts as a base for systems such as single-ply, polymer-modified bitumen and built-up roof. This specification also covers mineral wool insulation boards that incorporate a fibrous high density upper layer on the top surface 1.2 It is possible that the use of thermal insulation materials covered by this specification will be regulated by building codes or other agencies that address fire performance, or both. The fire performance of the material needs to be addressed through standard fire test methods established by the appropriate governing documents. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of the regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Mineral Wool Roof Insulation Board

ICS
91.100.60
CCS
Q25
发布
2017
实施

1.1 The purpose of this specification is to provide general requirements for products used to reduce solar gains on buildings by reflecting solar radiation from roofs and walls. Radiation Control Coating (RCC) is a liquid applied material that cures to form a solid coating having a solar reflectance of at least 0.8 and an ambient temperature infrared emittance of at least 0.8. 1.2 This specification covers the physical and mechanical properties of liquid-applied RCCs designed for exterior application for buildings. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems has the potential to result in non-conformance with the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Exterior Solar Radiation Control Coatings on Buildings

ICS
91.120.99
CCS
Q25
发布
2017
实施

4.1 The test methods described herein are intended to provide a basis for relative comparison of roof coverings. The test methods include simulated fire exposure to the outside of the roof coverings, and, where applicable, a determination as to whether the fire performance characteristics of the roof coverings will be adversely affected by prolonged exposure to rain. 4.2 These test methods measure the surface spread of flame and the ability of the roof covering material or system to resist fire penetration from the exterior to the underside of a roof deck under the conditions of exposure. 4.3 These test methods also provide criteria to determine if the roof covering material will develop flying burning material, identified as flying brands, when subjected to a 12-mph (5.3-m/s) wind during the simulated fire exposure tests. 4.4 These test methods do not necessarily illustrate the expected performance of roof coverings under all actual fire conditions, but they do provide a basis for comparing roof covering materials when subjected to fire sources that are described herein. 4.5 These test methods do not provide any basis for determining the fire resistance characteristics when exposed to a fire originating in the building to which the roofing material is applied. 4.6 The test methods described herein involve calibrating the test equipment using a calibration deck inclined at a slope of 5 in. per horizontal ft (0.416:1). The tests described herein are performed on test decks inclined at slopes up to and including 5 in. per horizontal ft. The severity of the test exposure decreases as the slope of the test deck decreases below 5 in. per horizontal ft. 1.1 This fire-test-response standard covers the measurement of the relative fire characteristics of roof coverings exposed to simulated fire sources originating outside the building. It is applicable to roof coverings intended for installation on either combustible or noncombustible roof decks when applied as intended for use. The following test methods are included: 1.1.1 Intermittent flame exposure test. 1.1.2 Spread of flame test. 1.1.3 Burning brand test. 1.1.4 Flying brand test. 1.1.5 Rain test. 1.2 Three classes of fire test exposure are described: 1.2.1 Class A Tests are applicable to roof coverings that are expected to be effective against severe fire exposure, afford a high degree of fire protection to the roof deck, do not slip from position, and are not expected to present a flying brand hazard.

Standard Test Methods for Fire Tests of Roof Coverings

ICS
13.220.50 ; 91.060.20
CCS
Q25
发布
2017
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号