Q70 建筑构配件与设备综合 标准查询与下载



共找到 783 条与 建筑构配件与设备综合 相关的标准,共 53

This European Standard specifies a test method for the determination of resistance to manual burglary attempts in order to assess the burglar resistant characteristics of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following means of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions. This European Standard does not directly cover the resistance of locks and cylinders to attack with picking tools. It also does not cover the attack of electric, electronic and electromagnetic operated burglar resistant construction products using attack methods that might defeat these characteristics. It is acknowledged that there are two aspects to the burglar resistance performance of construction products, their normal resistance to forced operation and their ability to remain fixed to the building. Due to the limitation of reproducing the fixing methods and building construction in a laboratory environment this aspect is not fully covered by the standard. This is particularly true with products built into a building. The performance of the fixed part of the product is evaluated using a standard sub frame. It is the manufacturer´s responsibility to ensure that guidance on the fixing of the product is contained in the mounting instructions and that this guidance is suitable for the burglar resistance class claimed for the product. As with the other referenced standards this specification uses a standard sub frame and the product is mounted according to the manufacturers' instructions. An example for the contents of the manufacturer´s installation instructions is given in Annex A of EN 1627:2011. This test method does not evaluate the performance of the fixing to the building. This European Standard does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241-1.

Pedestrian doorsets, windows, curtain walling, grilles and shutters. Burglar resistance. Test method for the determination of resistance to manual burglary attempts

ICS
13.310;91.060.50
CCS
Q70
发布
2011-06-30
实施
2011-06-30

This European Standard specifies a test method for the determination of resistance to dynamic loading in order to assess the burglar resistant properties of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following means of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions. There are two aspects to the burglar resistance performance of construction products, their normal resistance to forced operation and their ability to remain fixed to the building. Due to the limitation of reproducing the fixing methods and building construction in a laboratory environment this aspect is not fully covered by the standard. This is particularly true with products built into a building. The performance of the fixed part of the product is evaluated using a standard sub frame. It is the manufacturer´s responsibility to ensure that guidance on the fixing of the product is contained in the mounting instructions and that this guidance is suitable for the burglar resistance class claimed for the product. As with the other referenced standards this specification uses a standard sub frame and the product is mounted according to the manufacturer´s instructions. The fixing method to be considered is detailed in Annex A of EN 1627:2011. This test method does not evaluate the performance of the fixing to the building. This European Standard does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241-1.

Pedestrian doorsets, windows, curtain walling, grilles and shutters. Burglar resistance. Test method for the determination of resistance under dynamic loading

ICS
13.310;91.060.50
CCS
Q70
发布
2011-06-30
实施
2011-06-30

This European Standard specifies requirements and classification systems for burglar resistant characteristics of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following means of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions. It also covers products that include items such as letter plates or ventilation grilles. It specifies requirements for the burglar resistance of a construction product (as defined in 3.1 of this standard). This European Standard does not directly cover the resistance of locks and cylinders to attack with picking tools. It also does not cover precast concrete elements. It also does not cover the attack of electric, electronic and electromagnetic operated burglar resistant construction products using attack methods that might defeat these characteristics. NOTE 1 The mechanical parts of electric, electronic and electromagnetic operated burglar resistant construction products may be tested in electrical powerless condition. This European Standard does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241-1. NOTE 2 Construction products that can be reached or driven through by vehicles should be protected by appropriate measures such as barriers, extensible ramps, etc.

Pedestrian doorsets, windows, curtain walling, grilles and shutters. Burglar resistance. Requirements and classification

ICS
13.310;91.060.50
CCS
Q70
发布
2011-06-30
实施
2011-06-30

This European Standard specifies a test method for the determination of resistance to static loading in order to assess the burglar resistant properties of pedestrian door sets, windows, curtain walling, grilles and shutters. It is applicable to the following means of opening: Turning, tilting, folding, turntilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions. This European Standard does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241-1.

Pedestrian doorsets, windows, curtain walling, grilles and shutters. Burglar resistance. Test method for the determination of resistance under static loading

ICS
13.310;91.060.50
CCS
Q70
发布
2011-06-30
实施
2011-06-30

本标准规定了平开玻璃门用五金件(门夹、铰链、拉手)的术语和定义、分类、代号和标记、材料、要求、试验方法、检验规则及标志、包装、运输、贮存。 本标准适用于无框平开玻璃门用五金件,其他型式平开门用五金件可参考使用。

Fittings of glass swing door

ICS
91.060.50
CCS
Q70
发布
2011-06-03
实施
2011-12-01

Industrial, commercial and garage doors and gates - Product standard - Part 1 : products without fire resistance or smoke control characteristics.

ICS
91.060.50;91.090
CCS
Q70
发布
2011-06-01
实施

Industrial, commercial and garage doors and gates - Product standard - Part 1 : products without fire resistance or smoke control characteristics.

ICS
91.090
CCS
Q70
发布
2011-06-01
实施
2011-06-04

This Part of prEN 15269, which should be read in conjunction with EN 15269-1, covers the following types of steel rolling shutter assemblies: un-insulated manually operated rolling shutters, un-insulated powered rolling shutters, insulated manually operated rolling shutters and insulated powered rolling shutters. This document prescribes the methodology for extending the application of test results obtained from test(s) conducted in accordance with EN 1634-1. Subject to the completion of the appropriate test or tests selected from those identified in Clause 4 the extended application may cover all or some of the following non-exhaustive list: • Integrity only (E), radiation (EW) or insulated (EI1 or EI2) classifications; • shutter curtain; • wall/ceiling fixed elements (frame/suspension system); • decorative finishes; • intumescent, smoke, draught or acoustic seals; • alternative supporting construction(s).

Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies including their elements of building hardware. Fire resistance of steel rolling shutter assemblies

ICS
13.220.50;91.060.50
CCS
Q70
发布
2011-05-31
实施
2011-05-31

This European Standard specifies the test methods for evaluating:  the risks of decay of openable and fixed windows manufactured of different materials through increased moisture accumulation as a result of condensation or water vapour diffusion;  the influence of deformation on basic performances of openable and fixed windows manufactured of different materials exposed to different climates between their external and internal faces. Three test methods are to be differentiated. They take into account different cases of loadings.  Test method 1: For designs with low resistance to water vapour diffusion (normally designs with water vapour equalization holes); the test procedure is to be used for cross-sections where the danger is given by the moisture accumulation as a result of the condensation of moisture between the planking and the timber (see Annex A (informative), Figure A.1).  Test method 2.1 and 2.2: For designs with high resistance to water vapour diffusion (normally designs without water vapour equalization holes); the test procedure is to be used for cross-sections where the danger is given by the condensation of the moisture between the surface of the inner profile and the inner surface of the outer profile by having a different water vapour diffusion (see Annex A (informative), Figures A.2 and A.3).  Test method 3: For designs being sensitive to deformation; the test procedure is to be used for crosssections where they are sensitive to the function through deformation as a result of climatic loading. This European Standard defines the test procedures which are to be used in dependence of the potential risk of the design. This European Standard is relevant to initial type testing, i. e. to developments or changes in designs. It is not relevant to routine quality control or to proven designs. NOTE Designs are included in Annex A (informative). Annex B (normative) is the survey of general design criteria where tests are not necessary.

Windows. Behaviour between different climates. Test method

ICS
91.060.50
CCS
Q70
发布
2011-05-31
实施
2011-05-31

This European Standard specifies the safety and performance requirements for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises. This European Standard also covers commercial doors such as rolling shutters and rolling grilles used in retail premises which are mainly provided for the access of persons rather than vehicles or goods. These doors can include pass doors incorporated in the door leaf which are also covered by this European Standard. These devices can be manually or power operated. This European Standard does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000-6-3. Exclusions This European Standard does not apply to the following which are intended for a different use: lock gates and dock gates; doors on lifts; doors on vehicles; armoured doors; doors mainly for the retention of animals; theatre textile curtains; horizontally moving manually operated pedestrian doors with a leaf size less than 6,25 m2; horizontally moving power operated doors less than 2,5 m wide and 6,25 m2 area, designed principally for pedestrian use in accordance with prEN 12650-1; revolving doors of any size; railway barriers; barriers used solely for vehicles. This European Standard does not cover the radio part of doors. If a radio operating device is used, the relevant ETSI standards should be applied in addition. This European Standard does not contain any specific requirements for fire resistance or smoke control characteristics which are covered in prEN 13241-2. This European Standard does not contain any specific requirement for doors which are moving because of energy stored by dedicated means from human power such as manually tensioned springs. This European Standard does not contain any specific requirements for doors on escape routes. The ability to open the door leaf safely and easily cannot normally be achieved by industrial, commercial and garage doors due to size, weight and/or mode of operation. The noise emission of powered doors and gates is not considered to be a relevant hazard. Therefore this European Standard does not contain any specific requirements on noise in relation to the Machinery Directive. Specific applications This European Standard should also apply to power operated doors which have been created by the addition of power operation to an installed manual door in respect of the relevant requirements. Annex ZA does not apply to this kind of door. It also identifies requirements and classes of performance for additional characteristics considered to be of importance to the trade. When a door is part of the load carrying structure of the building the requirements of this European Standard can apply on a voluntary basis in addition to the requirements for the load carrying structure, which are not dealt with in this European Standard. Annex ZA does not apply for this kind of doors.

Industrial, commercial and garage doors and gates - Product standard - Part 1: Products without fire resistance or smoke control characteristics

ICS
91.090
CCS
Q70
发布
2011-04
实施

Thermal performance of windows and doors -- Calculation of thermal transmittance -- Part 1: General

ICS
91.060.50;91.120.10
CCS
Q70
发布
2011-03-22
实施

Thermal performance of windows and doors -- Calculation of thermal transmittance -- Part 2: Numerical method for frames

ICS
91.060.50;91.120.10
CCS
Q70
发布
2011-03-22
实施

This European Standard specifies requirements for butterfly valves having metallic bodies for use in flanged or butt welding piping systems and used for isolating, regulating or control applications. The PN and Class ranges are: PN 2,5; PN 6; PN 10; PN 16; PN 25; PN 40; Class 150; Class 300. The DN range is: DN 20; DN 25; DN 32; DN 40; DN 50; DN 65; DN 80; DN 100; DN 125; DN 150; DN 200; DN 250; DN 300; DN 350; DN 400; DN 450; DN 500; DN 600; DN 700; DN 750; DN 800; DN 900; DN 1000; DN 1200; DN 1400; DN 1600; DN 1800; DN 2000; DN 2200; DN 2400. DN 750 is used only for Class 150 and Class 300. For special application as industrial process control valves, see EN 1349 and EN 60534-2-1.

Industrial valves - Metallic butterfly valves

ICS
23.060.30
CCS
Q70
发布
2011-03
实施

本规程适用于现浇混凝土结构和预制构件所采用的钢框胶合板模板的设计、制作和施工应用。

Technical specification for plywood form with steel frame

ICS
CCS
Q70
发布
2011-01-07
实施
2011-10-01

BORED AND PREASSEMBLED LOCKS AND LATCHES

ICS
CCS
Q70
发布
2011-01-01
实施

POWER OPERATED PEDESTRIAN DOORS

ICS
CCS
Q70
发布
2011-01-01
实施

Release Devices - Closer Holder, Electromagnetic and Electromechanical

ICS
CCS
Q70
发布
2011-01-01
实施

The primary purpose is to establish a std. method of testing the performance of a steel door mounted in a hollow metal or channel iron frame installed with the appropriate anchors, under conditions that might reasonably be considered an accelerated field operating condition.

Test Procedure & Acceptance Criteria for - Physical Endurance for Steel Doors, Frames and Frame Anchors

ICS
91.060.50
CCS
Q70
发布
2011
实施

This standard defines performance-based and prescriptive-based methods for evaluating section interfaces. Inclusions: this specification is intended to cover residential garage door systems generally used for vehicular traffic.

Standard for Section Interfaces on Residential Garage Door Systems

ICS
91.060.50
CCS
Q70
发布
2011
实施

This specification recognizes that the effectiveness of a sheet radiant barrier is dependent on proper installation. Practice C1158 addresses use and installation of radiant barriers. This specification identifies the material properties that are important for sheet radiant barrier products. When appropriate, values for the properties have been stated. The user should consult the manufacturer about specific material properties are needed for a particular application. Radiant barriers shall be free of dust or other contaminants to remain effective. 1.1 This specification covers the general physical property requirements of radiant barrier materials for use in building construction. The scope is specifically limited to requirements for radiant barrier sheet materials that consist of at least one surface having a far-infrared emittance of 0.1 or less, such as metallic foils or metallic deposits mounted or unmounted on substrates. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 The following safety hazards caveat pertains only to the test methods (Section 10) described in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Sheet Radiant Barriers for Building Construction Applications

ICS
91.120.10 (Thermal insulation of buildings)
CCS
Q70
发布
2011
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号