Q81 供水、排水器材设备 标准查询与下载



共找到 2551 条与 供水、排水器材设备 相关的标准,共 171

NSF/ANSI 61 - Drinking Water System Components: Health Effects

ICS
13.060.20;91.140.60
CCS
Q81
发布
2012
实施

1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 This specification is the metric counterpart of Specification C655. Note 1???Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q81
发布
2012
实施

1.1 This specification covers reinforced elliptically shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2 Pipe designed for placement with the major axis horizontal shall be designated as “Horizontal Elliptical Pipe.” Pipe designed for placement with the major axis vertical shall be designated as “Vertical Elliptical Pipe.” 1.3 This specification is the SI companion to Specification C507. Note 18212;This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.

Standard Specification for Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q81
发布
2012
实施

1.1 This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2 This specification is the SI companion to Specification C506. Note 18212;This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.

Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe (Metric)

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q81
发布
2012
实施

This standard sets the minimum requirements for closed-vessel UV disinfection systems and equipment elements used for drinking water disinfection of Cryptosporidium, Giardia, and viruses. It does not include wastewater, reuse, or advanced oxidation treatment. Equipment and elements covered under this standard include UV reactors, related appurtenances and reactor validation.

Ultraviolet Disinfection Systems for Drinking Water

ICS
13.060.20
CCS
Q81
发布
2012
实施

This standard describes the various types and classes of propeller meters in sizes 2 in. (50 mm) through 72 in. (1,800 mm) for waterworks applications. These meters register by recording the revolutions of a propeller set in motion by the force of flowing water striking the blades.

Propeller-Type Meters for Waterworks Applications

ICS
91.140.60
CCS
Q81
发布
2012
实施

1.1 This specification covers reinforced concrete pipe intended to be used for the construction of pressure pipelines with low internal hydrostatic heads generally not exceeding 125 ft. 1.2 This specification is the inch-pound companion to Specification C361; therefore, no SI equivalents are presented in the specification.Note 1???Field tests on completed portions of the pipeline are not covered by this specification for the manufacture of the pipe but should be included in specifications for pipe laying.

Standard Specification for Reinforced Concrete Low-Head Pressure Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q81
发布
2012
实施

1.1 This specification covers single-cell precast reinforced concrete box sections cast monolithically and intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes and sewage.Note 1???This specification is primarily a manufacturing and purchasing specification. However, standard designs per the AASHTO LRFD Bridge Design Specifications are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that proper correlation of the loading conditions and the field requirements with the box section specified, and provision for inspection at the construction site, are required. 1.2 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.

Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers Designed According to AASHTO LRFD

ICS
91.100.30 (Concrete and concrete products); 93.030
CCS
Q81
发布
2012
实施

1.1 This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts. 1.2 This specification is the inch-pound companion to Specification C76M; therefore, no SI equivalents are presented in this specification. Reinforced concrete pipe that conform to the requirements of C76M, are acceptable under this Specification C76 unless prohibited by the Owner. Note 18212;This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site. Note 28212;Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (Specification C655).

Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q81
发布
2012
实施

1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 A complete metric companion to Specification C655 has been developedSpecification C655M; therefore, no metric equivalents are presented in this specification. Note 18212;Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q81
发布
2012
实施

Wrought Copper & Wrought Copper Allow Solder Joint Drainage Fittings - DWV

ICS
23.040.40
CCS
Q81
发布
2012
实施

Drinking water treament units - Health effects

ICS
13.060.20;91.140.60
CCS
Q81
发布
2012
实施

Residential wastewater treatment systems

ICS
91.140.80
CCS
Q81
发布
2012
实施

1.1 This specification covers glass fiber-reinforced polyester manholes and wetwells for use primarily in sanitary and storm sewer applications. 1.2 The values given in inch-pound units are to be regarded as the standard. The values in parentheses are provided for information purposes only. 1.3 The following precautionary caveat pertains only to the test methods portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note 18212;There is no known ISO equivalent to this standard.

Standard Specification for Glass-Fiber-Reinforced Polyester Manholes and Wetwells

ICS
13.060.30 (Sewage water)
CCS
Q81
发布
2012
实施

This standard describes the design, fabrication, installation, inspection, and testing of bolted aboveground thermoset fiberglass-reinforced plastic (FRP) panel-type tanks for potable water. Requirements for the fabrication, handling, construction, and testing of FRP panels, concrete and steel foundation structure, foundation, and accessories are included.

Bolted Aboveground Thermosetting Fiberglass-Reinforced Plastic Panel-Type Tanks for Water Storage

ICS
23.020.10
CCS
Q81
发布
2012
实施

1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 A complete metric companion to Specification C655 has been developed???Specification C655M; therefore, no metric equivalents are presented in this specification. Note 1???Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q81
发布
2012
实施

Evaluation of components and devices used in wastewater treatment systems

ICS
91.140.80
CCS
Q81
发布
2012
实施

Plumbing Fixture Fittings

ICS
91.140.70
CCS
Q81
发布
2012
实施

Solders for capillary soldering of fittings of copper and copper alloys for connecting the pipelines systems. Grades

ICS
77.120.60;77.120.99
CCS
Q81
发布
2012
实施
2014-01-01

Specification for 150 to 1500 mm [6 to 60 in] Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings for Sanitary Sewer Applications

ICS
93.030
CCS
Q81
发布
2012
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号