共找到 2551 条与 供水、排水器材设备 相关的标准,共 171 页
1.1 This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2 This specification is the inch-pound companion to C506M; therefore, no SI equivalents are presented in the specification. Note 18212;This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.
Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe
1.1 This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2 This specification is the SI companion to Specification C506. Note 1???This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.
Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe (Metric)
1.1 This practice describes the minimum loads to be applied when designing monolithic or sectional precast concrete water and wastewater structures with the exception of concrete pipe, box culverts, utility structures, and material covered in Specification C478. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Practice for Minimum Structural Design Loading for Monolithic or Sectional Precast Concrete Water and Wastewater Structures
1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 This specification is the metric counterpart of Specification C655. Note 18212;Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.
Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe (Metric)
This standard describes the design, fabrication, installation, inspection, and testing of bolted aboveground thermoset fiberglass-reinforced plastic (FRP) panel-type tanks for potable water. Requirements for the fabrication, handling, construction, and testing of FRP panels, concrete and steel foundation structure, foundation, and accessories are included.
Bolted Aboveground Thermosetting Fiberglass-Reinforced Plastic Panel-Type Tanks for Water Storage
1.1* Scope. 1.1.1 This standard shall cover the design, installation, and maintenance of automatic sprinkler systems for protection against the fire hazards in one- and two-family dwellings and manufactured homes. 1.1.2 This standard assumes that the sprinkler system is designed to protect against a fire originating from a single ignition location.
Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes
1.1 This specification covers the manufacture and acceptance of precast concrete pipe designed to conform to the owner's design requirements and to ASCE 15 or an equivalent design specification. 1.2 This specification is the companion to SI Specification C1417M; therefore, no SI equivalents are presented in this specification.
Standard Specification for Manufacture of Reinforced Concrete Sewer, Storm Drain, and Culvert Pipe for Direct Design
This British Standard gives recommendations and guidance on the provision and management of temporary water supplies and distribution networks to ensure the water supplied to users is wholesome.It is applicable to situations when a permanent supply is not available or not required,for example,at building sites and outdoor public events,or when there is an interruption in the public mains water supply.
Provision and management of temporary water supplies and distribution networks (not including provisions for statutory emergencies). Code of practice
Plastics piping systems for hot and cold water installations. Polyethylene of raised temperature resistance (PE-RT). Guidance for the assessment of conformity
Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks - Part 3 : lining with close-fit pipes.
Flexible hose assemblies in drinking water installations - Functional requirements and test methods.
Drainage systems on private ground - Part 4: Fields of application of sewage pipes and fittings of different materials
This European Standard specifies the requirements and test methods for materials, dimensiona and function for flexible hose assemblies, braided or not , designed for use with drinking water with an allowable maximum operating oressure (PMA) of 1 MPa and maximum operating temperature 70
Flexible hose assemblies in drinking water installations - Functional requirements and test methods; German version EN 13618:2011
Plastics piping systems - Thermoplastics pipes and fittings for hot and cold water - Test method for the resistance of mounted assemblies to temperature cycling
Plastics piping systems for water supply, and for drainage and sewerage under pressure. Polyethylene (PE). Fittings
Plastics piping systems for water supply, and for drainage and sewerage under pressure. Polyethylene (PE). General
Plastics piping systems for water supply, and for drainage and sewerage under pressure. Polyethylene (PE). Fitness for purpose of the system
Plastics piping systems for water supply, and for drainage and sewerage under pressure. Polyethylene (PE). Fittings
Thermoplastics piping systems for non-pressure underground drainage and sewerage - Test method for resistance to combined temperature cycling and external loading.
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved