Z15 大气环境有毒害物质分析方法 标准查询与下载



共找到 764 条与 大气环境有毒害物质分析方法 相关的标准,共 51

This European Standard specifies a method for sampling of Pb, Cd, As and Ni as part of the PM10 aerosol, microwave digestion of the samples and analysis by graphite furnace atomic absorption spectrometry or by inductively coupled plasma (quadrupole) mass spectrometry. This European Standard is applicable for the measurement of Pb, Cd, As and Ni as part of the PM10 aerosol fraction in the concentration ranges listed in Table 1. Table I -- Working ranges of the method in ng/m3 The actual lower limits of the working ranges depend upon the variability of the laboratory filter blank (5.3.1). The lower limits of the working ranges given in Table 1 are expected values based upon performance achieved in the field validation tests. Similarly the upper limits of the working ranges have been set arbitrarily based upon the maximum daily values measured during the field validation tests. The method can be applied to higher concentrations provided the PM10 collection characteristics of the sampler are not compromised.

Ambient air quality - Standard method for the measurement of Pb, Cd, As and Ni in the PM10 fraction of suspended particulate matter; English version of DIN EN 14902

ICS
13.040.20
CCS
Z15
发布
2005-10
实施

This European Standard specifies a method for the determination of particulate lead (Pb), cadmium (Cd), arsenic (As) and nickel (Ni) in ambient air that can be used in the framework of the European Council Directive on Ambient Air Quality Assessment and Management [1] and the 1 [2] and 4 [3] Daughter Directives. Performance requirements with which the method has to comply are specified in this European Standard. The performance characteristics of the method were determined in comparative field validation tests carried out at four European locations (see [4]). This European Standard specifies a method for sampling of Pb, Cd, As and Ni as part of the PM10 aerosol, microwave digestion of the samples and analysis by graphite furnace atomic absorption spectrometry or by inductively coupled plasma (quadrupole) mass spectrometry. This European Standard is applicable for the measurement of Pb, Cd, As and Ni as part of the PM10 aerosol fraction in the concentration ranges listed in Table 1. The actual lower limits of the working ranges depend upon the variability of the laboratory filter blank (5.3.1). The lower limits of the working ranges given in Table 1 are expected values based upon performance achieved in the field validation tests. Similarly the upper limits of the working ranges have been set arbitrarily based upon the maximum daily values measured during the field validation tests. The method can be applied to higher concentrations provided the PM10 collection characteristics of the sampler are not compromised.

Ambient air quality - Standard method for the measurement of Pb, Cd, AS, and Ni in the PM 10 fraction of suspended particulate matter

ICS
13.040.20
CCS
Z15
发布
2005-09-27
实施
2005-09-27

이 규격은 샘플링 기간 중 온도, 압력, 습도의 변화에 대하여 공기 중의 성분 등 측정 또

Air quality-Handling of temperature, pressure and humidity data

ICS
13.040.01
CCS
Z15
发布
2005-09-26
实施
2005-09-26

이 규격은 대기 중의 시료에서 매연 지수를 측정하는 방법에 대하여 규정한다. 이 방법은 공

Ambient air-Determination of a black smoke index

ICS
13.040.20
CCS
Z15
发布
2005-09-26
实施
2005-09-26

이 규격은 여과지에 포집한 납 시료의 화학적 분석을 위해 산 회화와 원자 흡수 분광법에 기

Ambient air-Determination of the particulate lead content of aerosols collected on filters(Atomic absorption spectrometric method)

ICS
13.040.20
CCS
Z15
发布
2005-09-26
实施
2005-09-26

ERRATUM

ICS
CCS
Z15
发布
2005-08-20
实施

This part of EN 14662 is in accordance with the generic methodology selected as the basis of the European Union for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period. This part of EN 14662 gives general guidance for the sampling and analysis of benzene in air, by diffusive sampling, solvent desorption and capillary gas chromatography. This part of EN 14662 is valid for the measurement of benzene in a concentration range of approximately 0,5 ug/m to 50 ug/m in an air sample typically collected over a period of several days or several weeks. A number of devices are recommended for the sampling of benzene, each device having a different range of applicability, particularly with regard to the optimum period of exposure. The upper limit of the useful range is set by the sorptive capacity of the activated charcoal and, subject to dilution of the analysed solution, by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene and/or interfering artefacts on the sampling devices or in the carbon disulphide. Alternative sorbents to activated charcoal may be used provided that the equivalence in performance characteristics of the procedure is demonstrated. Alternative desorption solvents to carbon disulphide may be used provided that the equivalence in performance characteristics of the procedure is demonstrated.

Ambient air quality - Standard method for measurement of benzene concentrations - Diffusive sampling followed by solvent desorption and gas chromatography

ICS
13.040.20
CCS
Z15
发布
2005-08-04
实施
2005-08-04

Ambient air quality - Standard method for measurement of benzene concentrations - Part 1: Pumped sampling followed by thermal desorption and gas chromatography; German version EN 14662-1:2005

ICS
13.040.20
CCS
Z15
发布
2005-08
实施

The standard describes a method for controlling the European limit value of 5 ?m for benzene by diffusive sampling. The method uses enrichment of benzene on polymerous sorbents, from which it is extracted by rapid heating. After gas chromatographic separation from other compounds benzene ise detected by a suitable detector.#,,#

Ambient air quality - Standard method for measurement of benzene concentrations - Part 4: Diffusive sampling followed by thermal desorption and gas chromatography; German version EN 14662-4:2005

ICS
13.040.20
CCS
Z15
发布
2005-08
实施

Ambient air quality - Standard method for measurement of benzene concentrations - Part 5: Diffusive sampling followed by solvent desorption and gas chromatography; German version EN 14662-5:2005

ICS
13.040.20
CCS
Z15
发布
2005-08
实施

Ambient air quality - Standard method for measurement of benzene concentrations - Part 3: Automated pumped sampling with in situ gas chromatography; German version EN 14662-3:2005

ICS
13.040.20
CCS
Z15
发布
2005-08
实施

The standard describes a method for controlling the European limit value of 5 ?m for benzene. The method uses enrichment of benzene on activated charcoal, from which it is extracted by a solvent. After gas chromatographic separation from other compounds benzene ise detected by a suitable detector.#,,#

Ambient air quality - Standard method for measurement of benzene concentrations - Part 2: Pumped sampling followed by solvent desorption and gas chromatography; German version EN 14662-2:2005

ICS
13.040.20
CCS
Z15
发布
2005-08
实施

This part of EN 14662 is in accordance with the generic methodology selected as the basis of the European Union for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period. This part of EN 14662 gives general guidance for the sampling and analysis of benzene in air by diffusive sampling, thermal desorption and capillary gas chromatography. This part of EN 14662 is valid for the measurement of benzene in a concentration range of approximately 0,5 μg/m to 50 μg/m in an air sample typically collected over a period of 14 days. The upper limit of the useful range is set by the sorptive capacity of the sorbent and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene and/or interfering artefacts on the sorbent. Artefacts are typically sub ng for sorbents such as graphitised carbon, but higher levels of aromatic hydrocarbons have been noted in other sorbents.

Ambient air quality - Standard method for measurement of benzene concentrations - Diffusive sampling followed by thermal desorption and gas chromatography

ICS
13.040.20
CCS
Z15
发布
2005-06-27
实施
2005-06-27

This part of EN 14662 is in accordance with the generic methodology selected as the basis of the European Union Reference Method for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period. The standard describes guidelines for measurements with, and type approval of, automated gas chromatographs. The use of automated instruments gives this part a different structure compared to the other parts including the procedure for selecting an appropriate automated gas chromatograph by means of type approval tests. Requirements for use in the field are also described. The standard is applicable to measurements of airborne benzene vapour in the concentration range from 0 μg/m to 50 μg/m (Standardised to 101,3 kPa and 293 K). This concentration range represents the certification range for benzene in the type approval test.

Ambient air quality - Standard method for measurement of benzene concentrations - Automated pumped sampling with in situ gas chromatography

ICS
13.040.20
CCS
Z15
发布
2005-06-27
实施
2005-06-27

This part of EN 14662 gives general guidance for the sampling and analysis of benzene in air by pumped sampling, thermal desorption and capillary gas chromatography. This part of EN 14662 is in accordance with the generic methodology selected as the basis of the European Union reference method for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period. This part of EN 14662 is valid for the measurement of benzene in a concentration range of approximately 0,5 μg/m to 50 μg/m in an air sample typically collected over a period of 24 hours. The upper limit of the useful range is set by the sorptive capacity of the sorbent and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capacity of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene and/or interfering artefacts on the sorbent. Artefacts are typically sub ng for sorbents, but higher levels of aromatic hydrocarbons have been noted in other sorbents. The detection limit will be approximately 1/10 of the lower concentration range.

Ambient air quality - Standard method for measurement of benzene concentrations - Pumped sampling followed by thermal desorption and gas chromatography

ICS
13.040.20
CCS
Z15
发布
2005-06-27
实施
2005-06-27

This document applies to air shutter frames and air doors for ventilation structures which are to remain functional after the passage of explosions with overpressures of up to 2 bar. Ventilation structures are protective systems to provide the ventilation flow after the occurrence of an explosion such that the effects of an explosion on the ventilation system can be limited and adequate possibilities remain for escape and rescue. NOTE These structures may be used when ventilation studies indicate that the air flow in the work place would be reduced considerably providing no safe escape for workers in cases where the structure is destroyed. Explosion proof ventilation structures will be individually evaluated for directional stability of ventilation flows and in order to ensure adequate ventilation flows.

Explosion prevention and protection in underground mines-Protective systems-Part 1:2-bar explosion proof ventilation structure

ICS
13.230;73.100.20
CCS
Z15
发布
2005-06-27
实施
2005-06-27

Workplace air - Determination of mercury and inorganic mercury compounds - Method by cold-vapour atomic absorption spectrometry or atomic fluorescence spectrometry.

ICS
13.040.30
CCS
Z15
发布
2005-06-01
实施
2005-06-20

Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury Corrigendum 1 to English of DIN EN 13211:2001-06

ICS
13.040.40
CCS
Z15
发布
2005-06
实施

This European standard specifies a manual reference method for the determination of the mass concentration of mercury in exhaust gases from ducts and chimneys. The method is applicable for the concentration range of total mercury from 0,001 to 0,5 mg/m3 in exhaust gases with the following composition: total suspended matter from 0 to 20 mg/m3; CxHy from 0 to 10 mg/m3; HCl from 0 to 50 mg/m3; HF from 0 to 10 mg/m3; SO2 from 0 to 250 mg/m3; NOx from 0 to 500 mg/m3; CO2 from 0 to 15 vol%; H2O (g) from 10 to 25 vol% (actual); O2 from 8 to 15 vol% (dry, actual); temperature from 60 to 140?#,,#

Air quality - Stationary source emissions - Manual methode of determination of the concentration of total mercury; German version EN 13211:2001, Corrigenda to DIN EN 13211:2001-06; German version EN 13211:2001/AC:2005

ICS
13.040.40
CCS
Z15
发布
2005-06
实施

This standard specifies procedures for the assessment and certification of fly ash in accordance with EN 450-1.

Fly ash for concrete - Part 2: Conformity evaluation; German version EN 450-2:2005

ICS
91.100.30
CCS
Z15
发布
2005-05
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号