Z60 污染物排放综合 标准查询与下载



共找到 444 条与 污染物排放综合 相关的标准,共 30

Stationary source emissions - Sampling and determination of gaseous fluoride content.

ICS
13.040.40
CCS
Z60
发布
2006-09-01
实施
2006-09-05

Stationary source emissions - Determination of the mass concentration of carbon monoxide (CO) - Reference method: Non-dispersive infrared spectrometry English version of DIN EN 15058:2006-09

ICS
13.040.40
CCS
Z60
发布
2006-09
实施

This Technical Specification is applicable to determine the acid and/or base neutralization capacity of a material. The property is expressed in mol/kg. This Technical Specification is a parameter specific test as specified in EN 12920. The application of this test method alone is not sufficient for the determination of the detailed leaching behaviour of a waste under specified conditions. The property allows assessing the final pH of mixed waste as well as consequences of external influences (carbonation, oxidation) on the pH of a waste. NOTE This generally requires the application of several test methods, behavioral modeling and model validation as specified in EN 12920.

Characterization of waste - Leaching behaviour tests - Acid and base neutralization capacity test

ICS
47.020.30
CCS
Z60
发布
2006-07-31
实施
2006-07-31

Stationary source emissions - Determination of the mass concentration of carbon monoxide (CO) - Reference method : non-dispersive infrared spectrometry.

ICS
13.040.40
CCS
Z60
发布
2006-07-01
实施
2006-07-20

本标准规定了云南省用水定额的术语、定义及分区,规定了农、林、牧、渔业、农村人畜,以及工矿企业、城镇生活等124个行业、477项用水定额值。本标准适用于取用水单位、个人和水资源管理,水利规划设计与研究、国民经济有关行业发展规划等,可参照使用。

Water quota

ICS
CCS
Z60
发布
2006-07-01
实施
2006-10-01

This International Standard is applicable to the measurement of the gaseous fluorides that are entrained in gases carried in stacks or ducts. The gaseous fluoride content is expressed as a mass of hydrogen fluoride in the stack gas. This International Standard is applicable to all stacks emitting gases with fluoride concentrations of below 200 mg/m3. It can be used for higher concentrations, but then the absorption efficiency of the bubblers should be checked before the results can be regarded as valid. The detection limit of the method is estimated as 0.1 mg m-3, based on a sample volume of 0,1 m3. All compounds that are volatile at the filtration temperature and produce soluble fluoride compounds upon reaction with water are measured by this method. The method does not measure fluorocarbons. The concentration of fluoride in the adsorbent solution is then measured using an ion selective electrode. The amount of fluoride measured is then expressed as hydrogen fluoride by convention, though this may not reflect the chemical nature of the compounds, which are measured.

Stationary source emissions - Sampling and determination of gaseous fluoride content

ICS
13.040.40
CCS
Z60
发布
2006-06-30
实施
2006-06-30

This European Standard specifies the Standard Reference Method (SRM) for sampling, and determining carbon monoxide content in ducts and stacks emitting to atmosphere. It describes the Non Dispersive Infra-Red (NDIR) analytical technique, including the sampling system and sample gas conditioning system, to determine CO in flue gases. This European Standard is the reference method for periodic monitoring and for calibration or control of Automatic Measuring Systems (AMS) permanently installed on a stack, for regulatory purposes or other purposes. To be used as the SRM, it is necessary to demonstrate that the performance characteristics of the method are lower than the performance criteria defined in this European standard and that the overall uncertainty of the method is less than ± 6 % relative at the daily Emission Limit Value (ELV). NOTE When the NDIR method is used as an AMS, refer to EN 14181 and other relevant standards provided by CEN TC 264. It is necessary for anybody who would like to use an Alternative Method instead of this Standard Reference Method to work out the demonstration of the equivalence according to the Technical Specification TS 14793, providing that his capability to carry out this demonstration is officially recognised by his national accreditation body or law. This Standard Reference Method has been evaluated during field tests on waste incineration, co-incineration installations and large combustion plants. It has been validated for CO concentrations with sampling periods of 30 min in the range of 0 mg/m3 to 400 mg/m3 for large combustion plants and 0 mg/m3 – 740 mg/m3 for waste and co-incineration. For waste incineration plants, Council Directive 2000/76/EC lays down emission values which are expressed in mg/m3, on dry basis at a specified value of O2 and at reference conditions of 273 K and 101,3 kPa.

Stationary source emissions - Determination of the mass concentration of carbon monoxide (CO) - Reference method: non-dispersive infrared spectrometry

ICS
13.040.40
CCS
Z60
发布
2006-06-30
实施
2006-06-30

Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 2 : extraction and clean-up of PCDDs/PCDFs.

ICS
13.040.40
CCS
Z60
发布
2006-06-01
实施
2006-06-05

The present part of this Standard specifies the extraction and clean-up procedures of the sampled PCDDs/PCDFs. It is integral part of the complet measurement procedure. The use of the other two parts EN 1948-1:2003 and EN 1948-3:2003 describing sampling or identification and quantification, respectively, is necessary for the determination of the PCDDs/PCDFs. This standard has been designed to measure PCDD/PCDF concentrations at about 0,1 ng I-TEQ/m cube in stationary source emissions.#,,#

Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 2: Extraction and clean-up of PCDDs/PCDFs English version of DIN EN 1948-2:2006-06

ICS
13.040.40
CCS
Z60
发布
2006-06
实施

This part of the Standard specifies the sampling of PCDDs/PCDFs. It is an integral part of the complete measurement procedure. The use of the other two parts EN 1948-2:2003 and EN 1948-3:2003 describing extraction and clean-up and identification and quantification, respectively, is necessary for the determination of the PCDDs and PCDFs.

Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs English version of DIN EN 1948-1:2006-06

ICS
13.040.40
CCS
Z60
发布
2006-06
实施

This International Standard is applicable to the measurement of the gaseous fluorides that are entrained in gases carried in stacks or ducts. The gaseous fluoride content is expressed as a mass of hydrogen fluoride in the stack gas. This International Standard is applicable to all stacks emitting gases with fluoride concentrations of below 200 mg/m3. It can be used for higher concentrations, but then the absorption efficiency of the bubblers should be checked before the results can be regarded as valid. The detection limit of the method is estimated as 0.1 mg m-3, based on a sample volume of 0,1 m3. All compounds that are volatile at the filtration temperature and produce soluble fluoride compounds upon reaction with water are measured by this method. The method does not measure fluorocarbons. The concentration of fluoride in the adsorbent solution is then measured using an ion selective electrode. The amount of fluoride measured is then expressed as hydrogen fluoride by convention, though this may not reflect the chemical nature of the compounds, which are measured.

Stationary source emissions - Sampling and determination of gaseous fluoride content

ICS
13.040.40
CCS
Z60
发布
2006-06
实施

Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 3: Identification and quantification of PCDDs/PCDFs English version of DIN EN 1948-3:2006-06

ICS
13.040.40
CCS
Z60
发布
2006-06
实施

This European Standard describes a manual method for sampling and determining SO_2 content in ducts and stacks emitting to the atmosphere by two analytical methods: Ion chromatography and Thorin method. This European Standard is the Standard Reference Method (SRM) for periodic monitoring and for calibration or control of Automatic Measuring Systems (AMS) permanently installed on a stack, for regulatory purposes or other purposes. To be used as the SRM, the user shall demonstrate that the performance characteristics of the method are better than the performance criteria defined in this European Standard and that the overall uncertainty of the method is less than _+ 20,0 % relative at the daily Emission Limit Value (ELV). An Alternative Method to this SRM may be used provided that the user can demonstrate equivalence according to the Technical Specification CEN TS 14793, to the satisfaction of his national accreditation body or law. This Standard Reference Method has been evaluated during field tests on waste incineration, co-incineration and large combustion installations. It has been validated for sampling periods of 30 min in the range of (0,5 to 2 000) mg/m3 SO2 for Ion Chromatography variant and 5 mg/m3 to 2 000 mg/m3 SO2 for Thorin method according to emission limit values laid down in the following Council Directives: -- Council Directive 2001/80/EC on the limitation of emissions of certain pollutants into the air from large combustion plants; -- Council Directive 2000/76/EC on waste incineration plants. The limit values of EU Directives are expressed in mg SO_2/m3, on dry basis and at the reference conditions of 273 K and 101,3 kPa.

Stationary source emissions - Determination of mass concentration of sulphur dioxide - Reference method; English version of DIN EN 14791:2006-04

ICS
13.040.40
CCS
Z60
发布
2006-04
实施

This European Standard describes the condensation/adsorption technique, including the sampling system, to determine the water vapour concentration in the flue gases emitting to atmosphere from ducts and stacks. This technique is usually used all over Europe for water vapour monitoring. However to be implemented as the Standard Reference Method (SRM), the user has to demonstrate that the performance characteristics of the method are better than the performance criteria defined in this European Standard and that the overall uncertainty of the method is less than + _20 % of the measured value. This European Standard as the Standard Reference Method (SRM) is used for periodic monitoring and for calibration or control of Automatic Measuring Systems (AMS) permanently installed on a stack, for regulatory purposes or other purposes. An Alternative Method to this SRM may be used provided that the user can demonstrate equivalence according to the Technical Specification CEN/TS 14793, to the satisfaction of his national accreditation body or law. The determination of water vapour is mainly necessary for: -- regulatory purposes, to express the concentration at standard conditions (on dry gas); -- adjust the flow rate for isokinetic sampling, when a dry gas flow rate metering device is used. For both applications, the quantity to be measured is the amount of water present in the gas phase (vapour), which does not include water droplets. This European Standard is applicable in the range from 4 % to 40 % relative humidity and for water vapour concentration from 29 g/m3 to 250 g/m3 as a wet gas, although for a given temperature the upper limit of the method is related to the maximum pressure of water in air or in the gas. This European Standard has been evaluated during field tests on waste incineration, co-incineration and large combustion installations. It has been validated for sampling periods of 30 min in the concentration range of 7 % to 26 % volume. In this European Standard all the concentrations are expressed in normal conditions (273 K and 101,3 kPa). NOTE For saturated conditions the condensation/adsorption method is not applicable. Some guidance is given in this European Standard to deal with flue gas when droplets are present.

Stationary source emissions - Determination of the water vapour in ducts; English version of DIN EN 14790:2006-04

ICS
13.040.40
CCS
Z60
发布
2006-04
实施

This European Standard describes the paramagnetic method, including the sampling and the gas conditioning system, to determine the oxygen concentrations in flue gases emitted to the atmosphere from ducts and stacks. This European Standard is the Standard Reference Method (SRM) for periodic monitoring and for the calibration or control of Automatic Measuring Systems (AMS) permanently installed on a stack, for regulatory purposes or other purposes. To be used as the SRM, the user shall demonstrate that the performance characteristics of the method are better than the performance criteria defined in this European Standard and that the overall uncertainty of the method is less than + 6,0 % of the measured concentration. NOTE When paramagnetism is the measurement principle used for AMS, reference should be made to EN 14181 and other relevant standards provided by CEN/TC 264. An alternative method to this SRM may be used provided that the user can demonstrate equivalence according to the Technical Specification CEN/TS 14793, to the satisfaction of his national accreditation body or law. This Standard Reference Method has been evaluated during field tests on waste incineration, co-incineration and large combustion installations. It has been validated for sampling periods of 30 min in the range: 5 % to 26 %. Oxygen concentration values, expressed in % volume, are used in order to allow emission measurements of pollutants to be standardised to the reference 02 concentration and dry gas conditions required by the following Council Directives: -- Council Directive 2001/80/EC on the limitation of emissions of certain pollutants into the air from large combustion plants; -- Council Directive 2000/76/EC on waste incineration plants.

Stationary source emissions - Determination of volume concentration of oxygen (O2) - Reference method - Paramagnetism; English version of DIN EN 14789:2006-04

ICS
13.040.40
CCS
Z60
发布
2006-04
实施

This European Standard describes the chemiluminescence method, including the sampling and the gas conditioning system, to determine the NO/NO2/NO,. concentrations in flue gases emitted from ducts and stacks to atmosphere. This European Standard is the Standard Reference Method (SRM) for periodic monitoring and for calibration or control of Automatic Measuring Systems (AMS) permanently installed on a stack, for regulatory or other purposes such as calibration. To be used as the SRM, the user shall demonstrate that the performance characteristics of the method are better than the performance criteria defined in this European Standard and that the overall uncertainty of the method is less than + 10 % relative at the daily Emission Limit Value (ELV). NOTE When the chemiluminescence method is the measurement principle used for AMS, reference should be made to EN 14181 and other relevant standards provided by CEN TC 264. An Alternative Method to this SRM may be used provided that the user can demonstrate equivalence according to the Technical Specification CEN TS 14793, to the satisfaction of his national accreditation body or law. This SRM has been evaluated during field tests on waste incineration, co-incineration and large combustion installations. It has been validated for sampling periods of 30 min in the range of 0 mg NO2/m3 to 1 300 mg NO2/m3 for large combustion plants and 0 mg NO2/m3 to 400 mg NO2/m3 for waste incineration, according to emission limit values (ELVs) laid down in the following Council Directives: -- Council Directive 2001/80/EC on the limitation of emissions of certain pollutants into the air from large combustion plants; -- Council Directive 2000/76/EC on waste incineration plants. The ELVs for NOx (NO + NO2) in EU directives are expressed in mg NO2/m3, on dry basis, at a reference value for 02 and at the reference conditions (273 K and 101,3 kPa).

Stationary source emissions - Determination of mass concentration of nitrogen oxides (NOx) - Reference method: Chemiluminescence; English version of DIN EN 14792:2006-04

ICS
13.040.40
CCS
Z60
发布
2006-04
实施

This European Standard specifies the sampling of PCDDs/PCDFs. It is an integral part of the complete measurement procedure. The use of the other two parts EN 1948-2 and EN 1948-3 describing extraction and clean-up and identification and quantification, respectively, is necessary for the determination of the PCDDs/PCDFs. This European Standard has been developed to measure PCDD/PCDF concentrations at about 0,1 ng I-TEQ/m3 in stationary source emissions. This European Standard specifies both method validation and a framework of quality control requirements which shall be fulfilled by any PCDD/PCDF sampling. The user has the possibility to choose between three different methods: - "filter/condenser method" - "dilution method" - "cooled probe method" Each sampling method is illustrated by some sampling systems described in detail in Annex B as examples of proven procedures. During comparison measurements of the three sampling methods on municipal waste incinerators at the level of about 0,1 ng I-TEQ/m3 these methods have been deemed comparable within the expected range of uncertainty. Validation trials were performed on the flue gas of municipal waste incinerators at the level of about 0,1 ng I-TEQ/m3 and a dust loading of from 1 mg/m3 to 15 mg/m3. Although this European Standard is primarily developed and validated for gaseous streams emitted by waste incinerators, the practical experience shows that it can be applied for wide concentration ranges and various emission sources. The procedure described in the three parts of EN 1948 specifies requirements which shall be met in order to measure the 17 congeners necessary to calculate the total I-TEQ (see Table A.1). Besides the determination of PCDDs/PCDFs the described measurement methods are suitable for determination of other low-volatile substances, e.g. of dioxin-like PCBs (details for sampling and analyses see CEN/TS 1948-4), although no validated performance characteristics are available yet.

Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Sampling of PCDDs/PCDFs

ICS
13.040.40
CCS
Z60
发布
2006-03-31
实施
2006-03-31

This European Standard specifies the extraction and clean-up procedures of the sampled PCDDs/PCDFs. It is an integral part of the complete measurement procedure. The use of the other two parts EN 1948-1:2006 and EN 1948-3:2006 describing sampling or identification and quantification, respectively, is necessary for the determination of the PCDDs/PCDFs. This European Standard has been designed to measure PCDD/PCDF concentrations at about 0,1 ng I-TEQ/m3 in stationary source emissions. This European Standard specifies both method validation and a framework of quality control requirements which shall be fulfilled by any PCDD/PCDF extraction and clean-up methods to be applied. Some methods are described in detail in Annex A as examples of proven procedures. Each of the three sampling methods (Part 1) can be combined with the extraction and clean-up (Part 2) and the identification and quantification (Part 3) to complete the measurement procedure. During comparison measurements of the three sampling methods on municipal waste incinerators at the level of about 0,1 ng I-TEQ/m3 these methods have been deemed comparable within the expected range of uncertainty. Validation trials were performed on the flue gas of municipal waste incinerators at the level of about 0,1 ng I-TEQ/m3 and a dust loading of from 1 mg/m3 to 15 mg/m3. Although this European Standard is primarily developed and validated for gaseous streams emitted by waste incinerators, the practical experience shows that it can be applied for wide concentration ranges and various emission sources. The procedure described in the three parts of EN 1948:2006 specifies requirements which shall be met in order to measure the 17 congeners necessary to calculate the total I-TEQ (see Table A.1 of EN 1948-1:2006). Besides the determination of PCDDs/PCDFs the described measurement methods are suitable for determination of other low-volatile substances, e.g. of dioxin-like PCBs (details for sampling and analyses see CEN/TS 1948-4), although no validated performance characteristics are available yet.

Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Extraction and clean-up of PCDDs/PCDFs

ICS
13.040.40
CCS
Z60
发布
2006-03-31
实施
2006-03-31

This European Standard specifies the identification and quantification procedures of the sampled PCDDs/PCDFs. It is an integral part of the complete measurement procedure. The use of the other two parts of this standard, EN 1948-1:2006 and EN 1948-2:2006, describing sampling and extraction and clean-up, respectively, is necessary for the determination of the PCDDs/PCDFs. This European Standard has been designed to measure PCDD/PCDF concentrations at about 0,1 ng ITEQ/ m3 in stationary source emissions. This European Standard specifies both method validation and a framework of quality control requirements which shall be fulfilled by any PCDD/PCDF identification and quantification methods to be applied. Some methods are described in detail in Annex A as examples of proven procedures. Each of the three sampling methods (Part 1) can be combined with the extraction and clean-up (Part 2) and the identification and quantification (Part 3) to complete the measurement procedure. During comparison measurements of the three sampling methods on municipal waste incinerators at the level of about 0,1 ng I-TEQ/m3 these methods have been deemed comparable within the expected range of uncertainty. Validation trials were performed on the flue gas of municipal waste incinerators at the level of about 0,1 ng I-TEQ/m3 and a dust loading of from 1 mg/m3 to 15 mg/m3. Although this European Standard is primarily developed and validated for gaseous streams emitted by waste incinerators, the practical experience shows that it can be applied for wide concentration ranges and various emission sources. The procedure described in the three parts of EN 1948:2006 specifies requirements in order to measure every 2,3,7,8-chlorine substituted PCDD/PCDF congener required to calculate the total I-TEQ (see Table A.1 of EN 1948-1:2006). Besides the determination of PCDDs/PCDFs the described measurement methods are suitable for determination of other low-volatile substances, e.g. of dioxin-like PCBs (details for sampling and analyses see CEN/TS 1948-4), although no validated performance characteristics are available yet.

Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Identification and quantification of PCDDs/PCDFs

ICS
13.040.40
CCS
Z60
发布
2006-03-31
实施
2006-03-31

This European Standard specifies the identification and quantification procedures of the sampled PCDDs/PCDFs. It is an integral part of the complete measurement procedure. The use of the other two parts of this standard, EN 1948-1:2006 and EN 1948-2:2006, describing sampling and extraction and clean-up, respectively, is necessary for the determination of the PCDDs/PCDFs. This European Standard has been designed to measure PCDD/PCDF concentrations at about 0,1 ng ITEQ/ m3 in stationary source emissions. This European Standard specifies both method validation and a framework of quality control requirements which shall be fulfilled by any PCDD/PCDF identification and quantification methods to be applied. Some methods are described in detail in Annex A as examples of proven procedures. Each of the three sampling methods (Part 1) can be combined with the extraction and clean-up (Part 2) and the identification and quantification (Part 3) to complete the measurement procedure. During comparison measurements of the three sampling methods on municipal waste incinerators at the level of about 0,1 ng I-TEQ/m3 these methods have been deemed comparable within the expected range of uncertainty. Validation trials were performed on the flue gas of municipal waste incinerators at the level of about 0,1 ng I-TEQ/m3 and a dust loading of from 1 mg/m3 to 15 mg/m3. Although this European Standard is primarily developed and validated for gaseous streams emitted by waste incinerators, the practical experience shows that it can be applied for wide concentration ranges and various emission sources. The procedure described in the three parts of EN 1948:2006 specifies requirements in order to measure every 2,3,7,8-chlorine substituted PCDD/PCDF congener required to calculate the total I-TEQ (see Table A.1 of EN 1948-1:2006). Besides the determination of PCDDs/PCDFs the described measurement methods are suitable for determination of other low-volatile substances, e.g. of dioxin-like PCBs (details for sampling and analyses see CEN/TS 1948-4), although no validated performance characteristics are available yet.

Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 3: Identification and quantification of PCDDs/PCDFs

ICS
13.040.40
CCS
Z60
发布
2006-03-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号