Morphologi G3-ID 粒...

Morphologi G3-ID 粒度、粒形及化学组分自动分析仪参数指标

参数指标我要纠错




       技术参数:

  技术:静态自动成像与拉曼光谱相结合。

  形态分析:静态自动成像

  粒度范围:0.5 µm - 1000 µm*(对于某些应用,上限可能高达10mm*)

  测量的颗粒特性:粒度、粒形、透明度、数量、位置

  粒度参数:当量圆 (CE) 直径、长度、宽度、周长、面积、zei大间距、等效球(SE)体积

  粒形参数:长宽比、圆度、凸度、延伸率、高灵敏(HS)圆度、实积度

  颗粒透明度参数:灰度平均值,灰度标准差

  整体式样品分散装置选件(仅Morphologi G3S -ID):用于干粉的全自动分散及测量,手动或SOP控制分散压力、注入时间以及停留时间。

  检测器:彩色CCD阵列

  像素尺寸 2.78 um x 2.78 um

  光学系统:Nikon CFI 60 明视场/暗视场系统

  化学鉴定的粒度范围:以样品及样品培养基为准。

  拉曼光谱仪Kaiser 光学系统,含RamanRxn1。

  光谱性能:150 cm-1 至 1850 cm-1, 4 cm-1分辨率

  激光规格:波长 785nm;光谱仪功率输出<500 mW;样品功率输出 > 10 mW 标称;放大 50x条件下的激光光斑尺寸为 3 µm。


通用

技术:Static automated imaging combined with Raman spectroscopy

Morphological analysis:Static automated imaging

粒径尺寸:1 µm – 1000 µm*

测量颗粒性质:Size, shape, transparency, count, location, chemical identification

粒径参数:Circle equivalent (CE) diameter, length, width, perimeter, area, maximum distance, sphere equivalent (SE) volume, fiber total length, and fiber width

粒形参数:Aspect ratio, circularity, convexity, elongation, high sensitivity (HS) circularity, solidity fiber elongation, fiber straightness 

Particle transparency parameters: Intensity mean, intensity standard deviation


Sample dispersion样品分散

Dispersion mechanism: Sample entrainment, leading to particle shear and particle impaction 

Dispersion pressure range: 0.5 bar – 5 bar

Dispersion pressure precision: 0.1 bar increments

Injection time range: 5 msec - 100 msec

Sample Settling time: 1 s - 600 s


Sample presentation options:

4-slide holder for standard microscope slides 

2-slide holder for large microscope slides 

25 mm and 47 mm dia. holders for membrane filters

Thin-path wet cell for low volume particle suspensions


Microscope*

Light source: White light, brightfield diascopic and episcopic

Detector: 5M pixel 2592 x 1944 color CCD array

Pixel width: 2.78 µm x 2.78 µm

Optical system: Nikon CFI 60 brightfield/darkfield system

Lens: 2.5x, 5x, 10x, 20x, 50x

Particle size: [For fully automated Chemical ID measurements (see Morphologi G3 product page for standard particle size specification)] 

2.5x: 100 µm – 1000 µm (nominal) 

5x: 25 µm – 420 µm (nominal) 

10x: 20 µm – 210 µm (nominal) 

20x: 20 µm – 100 µm (nominal) 

50x: 1 µm – 40 µm (nominal)


Spectrometer 

Chemical analysis: Raman spectroscopy

Raman spectrometer: Kaiser Optical Systems Inc. RamanRxn1

Spectral performance: 150 cm-1 to 1850 cm-1, 6 cm-1 resolution

Wavelength: 785 nm

Power:<500 mW (spectrometer)

Power: > 10 mW nominal (at sample)

Laser spot size: 3 µm at 50x magnification

Laser safety: Class 3B

Chemical identification method: Spectral correlation

Patents: The Morphologi G3-ID and Morphologi G3-ID are protected by copyright and design rights, together with patents based on EP2106536A1 and US8111395B2


Weight and dimensions:

Dimensions (W, D, H): Main instrument: 440 mm x 760 mm x 750 mm

Dimensions (W, D, H): Spectrometer: 584 mm x 448 mm x 203 mm

Weight: Main instrument: 80 kg approx

Weight: Spectrometer: 27.7 kg

Operating environment:

Power: 100 V - 240 V ac 50/60 Hz 6.0 A

Operating temperature (°C): +15°C to +30°C

Storage temperature: -15°C to +30°C

Humidity: 0%–95%, non-condensing


Notes

*: Sample and substrate dependent. Instrument can also be used as a Morphologi G3. See Morphologi G3 page for details on performance capabilities