OCMA-300/305油份分析...
参数指标我要纠错

技术参数

型号OCMA-300/305OCMA-310/315OCMA-350/355
分析方法非分散性红外法NDIR     非分散性红外法NDIR非分散性红外法 NDIR
校准自动  手动手动
样品槽 内置内置可分离样品管
量程0-200mg/l0-200mg/l 0-200mg/l(油分) 
0-1000mg/kg(土壤)
0-1Abs(吸光度)
重复性0-9.9mg/l: ±0.2mg/l ±1 digit 0-9.9mg/l: ±0.4mg/l ±1 digit 
10-99.9mg/l: ±2.0mg/l ±1 digit 10-99.9mg/l: ±2.0mg/l ±1 digit 
100-200mg/l: ±4.0mg/l ±1 digit 100-200mg/l: ±4.0mg/l ±1 digit

Application: Oil contamination of fresh and salt water


Principle: Solvent extraction, NDIR analysis (Infrared spectroscopy)


Detector: Pyroelectric sensor


Measuring Range: 0 to 200 mg/L


Resolution:

0 to 99.9 mg/L; 0.1 mg/L

100 to 200 mg/L; 1 mg/L


Repeatability:

0 to 9.9 mg/L; ± 0.2 mg/L ± 1 digit

10.0 to 99.9 mg/L; ± 2 mg/L ± 1 digit

100 to 200 mg/L; ± 4 mg/L ± 1 digit


Measurement: Automatic after introduction of the oil in water sample or manual operation, selectable


Calibration: Automatic zero and span


calibration after the oil in water sample is introduced to the instrument.


Extraction Solvent:

HORIBA H-997 solvent


Sample/Solvent Volume: 20 mL/10 mL


Extraction Method: Built-in extractor for oil in water samples


Display:

Measured value; 3 digits LCD with backlight

Message; Character display LCD with

backlight (16 × 2 characters)

Functions: Data memory up to 50 data,

Self diagnostics, Stable type display,

Interactive operation, Calendar clock

Output: RS-232C and parallel printer port

Ambient Temperature: 0 to 40 ℃

Power Requirement:

100 to 240 V AC ± 10%, 50/60 Hz

100 to 120 V AC; approx. 80 VA

200 to 240 V AC; approx. 120 VA

Dimensions:

200(W)× 315(D)× 342(H) mm

7.8(W)× 12.4(D)× 13.5(H) in

Mass: Approx. 7 kg/15.5 lb


相关测油仪/油分浓度仪