技术参数:
型号 | Defender 510 | Defender 520 | Defender 530 | ||
流量范围 | 510L, 5-500ml/min | 520L, 5-500ml/min | 530L, 5-500ml/min | ||
流量精度 | 1% | 1% | 1% | ||
标准的精度 | N/A | N/A | 1.2% | ||
可选 | 流量 | mL/min, L/min, | mL/min, L/min, | mL/min, L/min, | |
标准化 | N/A | N/A | smL/min, sL/min, | ||
温度 | N/A | ℃ ℉ | ℃ ℉ | ||
压力 | N/A | mmHg, PSI, kPa | mmHg, PSI, kPa | ||
温度和压力传感器 | No | Yes | Yes | ||
压力 | N/A | 3.5 mmHg (典型) | 3.5 mmHg (典型) | ||
温度 | N/A | 0.8℃ (典型) | 0.8℃ (典型) | ||
每次读数时间 | 1~15 秒 | ||||
读数模式 (选择从1到100次测量的平均值) | 单次 (手动), 连续或突发模式 | ||||
气体兼容性 | 吴腐蚀性气体、不结露气体, 湿度小于70% | ||||
流动模式 | 压迫或抽吸 | ||||
测量单元 | 一体式 | ||||
AC 交流直流变换器/充电器 | 12V DC, > 250ma, 2.5mm中心位置 | ||||
Battery System电池类型 | 6V 可充电密封铅酸蓄电池,典型工作时间6~8 小时 | ||||
电池运行时间 (5 次/分钟) | 背景光打开3小时, 背景光关闭 8小时 | ||||
压入或抽吸附件 | 软管 | ||||
操作压力 (绝对) | 15 PSI | ||||
显示 | 带背光的图形LCD液晶显示器 | ||||
数据端口 (使用优化软件) | RS-232串口 | ||||
数据电缆 (使用优化软件) | 1 米 Defender校准器至电脑的串口 | ||||
防护箱 | 软质或硬质仪器箱 | ||||
尺寸(H x W x D) | 5.5”x6”x3”/140x150x75mm | ||||
重量 | 29oz/820g | ||||
服从:RoHS-和CE |
530L流量校准器Bios Defender 530-Low Flow
Bios Defender 530 Calibrator -- Coming January 2010
The Bios Defender 530, with
the ability to take both volumetric and standardized readings, is the
latest addition to the popular Defender 510 and 520 line of Bios DryCal
primary flow calibrators. Automatic correction of readings for
temperature and pressure, rather than merely recording of ambient
conditions, is essential for many applications.
The Defender 530, like the other instruments in the line, provides
users with a true primary flow calibrator for industrial hygiene,
environmental and laboratory applications. The design offers low cost,
light weight and ultra-compact size, incorporating the highly-regarded
DryCal technology. It is small enough to fit easily into a slim
briefcase for convenient transport.
Like
all Bios calibrators, the Defender 530 is easy to use. Turn it on.
Connect it to a sampling pump. Start taking readings. It's as simple as
that. Calibrations within a minute with no messy soap bubble solutions.
The
Defender 510, 520 and 530 can take hands-free continuous readings while
quickly and accurately setting the flow rate on air sampling pumps or
other instruments. The Defender 510/520/530 calibrators connect to any
PC and pre- and post-calibration data can be downloaded with the
included Integrator 110 with the Optimizer Collect Light software.
Bios Defender 530 Specifications | |
Size | 5.5“H x 6“W x 3“D 140 mm x 150 mm x 75 mm |
Weight | 29 oz. / 820 g |
Flow Ranges | |
DryCal Defender Low (L) Flow: | 5 to 500 ccm |
DryCal Defender Medium (M) Flow: | 50 - 5,000 ccm |
DryCal Defender High (H) Flow: | 300 - 30,000 ccm |
Accuracy | |
Volumetric | ±1.0% |
Standardized | ±1.2% |
User-Selectable Measurement Units | |
Volumetric Flow | mL/min, L/min, cc/min, cf/min |
Standarized Flow | smL/min, sL/min, scc/min, scf/min |
Pressure | mmHg, PSI, kPa |
Temperature | ºC, ºF |
Readings | |
Approximate Time per Reading | 1-15 seconds |
Reading Styles | Single (manual), Continuous or Burst, with averaging function user-selectable from 1 to 100 measurements |
Gas Compatibility | Use with non-corrosive, non-condensing, non-combustible gases, less than 70% humidity |
Flow Modes | Suction or Pressure |
Measurement Cell Style | Integrated |
Temperature & Pressure Sensors | In the flow stream Press: 3.5 mmHg (typical), 7.0 mm (max) Temp: 0.8 °C (typical) 1.3 °C (max) |
Battery System | |
AC Adapter/Charger | 12 DC, >250 ma, 2.5 mm, center positive |
Battery | 6V rechargeable, sealed lead-acid, 6-8 hours typical operation |
Battery Operational Time | (5 cycles/min), 3 hours backlight on, 8 hours backlight off |
Pressure & Suction Fittings | ¼” ID Hose Barb |
Display | Backlit graphical LCD |
Storage Temperature | 0-70 °C |
Ambient Humidity | 0-70% - non-condensing |
Operating Pressure | (Absolute) 15 PSI |
Warranty | Instrument: 1 year, Battery: 6 months |
Data Port | Serial RS-232 (for use with Optimizer Collect software) |
Data Cable | 1 meter (Defender Data Port to PC Serial Port) |
Protective Case | Soft side or Pelican cases available |
Laboratory Accreditation | Backed by ISO 17025 accreditation by NVLAP of NIST |
Instrument Certification | RoHS and CE Compliant |
Bios Defender 500 Kits Include: One flow cell, Bios Optimizer 110 PC Serial Cable, Software CD, AC Power Adapter/Charger, Plastic Leak Test Caps (2), NIST-Traceable Calibration Certificate and Mini-Manual. |
Bios Integrator 110 and Optimizer Collect Software
The
Defender 510/520 and the Defender 530 come standard with the Bios
Integrator 110 and Optimizer Collect Light software for bullet-proof
transfer of an ASCII text file of the flow data into an Excel® spread
sheet with automatic recording and graphing of flow measurements.
The
Optimizer Collect software helps to meet the needs of ISO, TQM, or
occupational health and safety management systems by providing a secure
audit trail for all pump calibrations, regardless of the pump type or
manufacturer.
The
basic Bios Optimizer Collect Light allows users to download data
directly to a Microsoft Excel® preconfigured Spreadsheet.for easier
collection, storage and record-keeping.
Enter
flow rates from pumps or other flow source and calibrate the flow
source. Data is recorded directly to a preconfigured Microsoft Excel®
Spreadsheet.
Enter flow data from a flow meter and capture and compare the flow
measurements from tje Bios DryCal precision calibrator into a
preconfigured Microsoft Excel® Spreadsheet.
Optiimizer Collect light is upgradeable to a full version of Collect by
purchasing an Activation code from Bios for automatic multi-point
calibration of MFC/MFM using DryCal and Integrator 110.
The
upgrade to the Bios Optimizer Collect full version allows the user to
not only capture, but secure, organize, search and present data. It
stores the records in a small but secure SQL database. These records can
also be easily opened in a variety of off-the-shelf database
applications, including Microsoft Excel and Access.
Accuracy
Proven percent of reading accuracy is supported by ISO 17025 accreditation by NVLAP of NIST < >Integrated temperature sensors and pressure transducers placed directly in the flow stream for optimum standardized results.Convenience
Large illuminated flow cell viewing window
Rated for extreme cold operation, down to -20 ºC
Choose between flow units
Take individual readings, continuous hands-free readings, or set to read in time intervals anywhere from one minute to sixty minutes between readings
Bios Defender 510 to calibrate personal air samplers and other volumetric instruments; < >Bios
Defender 520 “three-in-one“ to calibrate volumetric instruments, record
ambient temperature and pressure conditions for the audit trail, or to
calibrate devices that read in mass flow; Bios
Defender 530, for both volumetric flow readings or standarized
readings, which correct for temperature and pressure, or to calibrate
devices that read in mass flow,. Software:
The upgrade to the Bios Optimizer Collect Full version allows the user to not only capture, but secure, organize, search and present data. It stores the records in a small but secure SQL database. These records can also be easily opened in a variety of off-the-shelf database applications, including Microsoft Excel and Access.
The Integrator 110 and Optimizer Collect Light software is bundled with the Defender with an integrated serial PC interface for easy transfer of flow data to a text file, with automatic recording and graphing of flow measurements.
Available in three models for application expansion. Use the
Standardized: smL/min, L/min, cc/min, scf/min
– Volumetric: mL/min, L/min, cc/min, or cf/min
Include up to one hundred readings in a group average
RoHS (Restriction of Hazardous Substances) compliant for Europe < > Automatic ShutoffFlexibility
Navigation menu and a large, illuminated graphical display with zoom feature
Housed in a molded case with rubber handgrips for a better feel and a sleeker, more contemporary look