Albira 性能指标

Full Field Accuracy (FFA)

FFA offers real, homogeneous sub-millimetric volumetric PET resolution in all three axes in the whole field of view, with superior precision in quantification based on: Exclusive continuous crystal detectors with new Si PM technology and true depth of interaction 3D precision equivalent to 10+ layer pixelated crystal detectors.


Virtual pixels optimizing very fast, low dose, maximum sensitivity studies and allowing software based performance upgrades Proprietary electronics and software with row and column readout, enabling advanced depth-of-interaction measurement and correction.


This patented technology generates an area of optimum resolution up to 10 times larger than conventional options.


System Specifications系统参数

  • Imaging Modalities: PET, SPECT, CT

  • Core Technologies: Patented continous crystal technology with Row And Column readout + proprietary electronics + HR 3D DOI

  • Unit Size: Single compact footprint

  • Shielding: Fully Shielded

  • Weight: 800 kg

  • Bore Size: 105


Animal Care Monitoring And Control

  • Anesthesia: Fully integrated. Compatible with most common commercial gas systems

  • Animal Handling System: Reliable, easy to use rat and mouse beds; Fully compatible with BRUKER MR

  • Physiological Signals: ECG, Respiration, Temperature, And Blood Pressure

  • Temperature Control System: Electrically heated mats for rat And mouse

  • Video Monitoring: Realtime camera

  • Gating Acquisition: Cardiac and Respiratory For PET and SPECT; Dual Gating for PET


Software And Workstation

  • Fully Integrated Albira Suite: ACQUIRER: Image Acquisition, RECONSTRUCTOR: Image Reconstruction, MANAGER: Study and Protocol Management, SUPERVISOR: Quality Control

  • Image Analysis Software: PMOD (PBAS, PFUS, PKIN MODULES INCLUDED)

  • 3D Rendering Software: VOLVIEW (+ PMOD)

  • Workstation: Dedicated Server; All Functionalities on a single system

  • Reconstruction: GPU Based, Scalable To 4 GPUs (PET); CPU Based SPECT and CT

  • Data Storage: 3 * 4TB RAID 5 Configuration; Upgradable on same Workstation


PET System 3 Ring

  • Module Architecture: 24 Modules, 8 modules per ring; Patented continous crystal coupled to 12x12 SiPM; Propietary electronics optimized for HR 3D DoI;

  • Spatial Resolution: Up to 0,7 mm; Guaranteed submilimetric volumetric resolution; FULL FIELD ACCURACY: Homogeneous resolution better than 1,2 mm in the whole FoV of 80+ mm;

  • Axial FOV: 148 mm

  • Transaxial FOV: 80 mm

  • Sensitivity: 12%; 9% NEMA

  • Average Energy Resolution: 17%

  • Reconstruction Algorithm: MLEM, Ultra fast GPU based

  • Sensitivity: 9%

  • NECR Mouse: Peak: 560 kcps at 35 MBq

  • NECR Rat: Peak: 330 kcps at 43 MBq


PET System 1 Ring

  • Module Architecture: 8 Modules in 1 ring configuration; Patented continous crystal coupled to 12x12 SiPM; Propietary electronics optimized for HR 3D DoI

  • Spatial Resolution: Up to 0,7 mm[1]; Guaranteed submilimetric volumetric resolution; FULL FIELD ACCURACY: Homogeneous resolution better than 1,2 mm in the whole FoV of 80+ mm

  • Axial FOV: 46 mm

  • Transaxial FOV: 80 mm

  • Sensitivity: 4,5%; 3% NEMA

  • Average Energy Resolution: 17%

  • Reconstruction Algorithm: MLEM, Ultra fast GPU based

  • NECR Mouse: Peak: 80 kcps at 35 MBq

  • NECR Rat: Peak: 20 kcps at 43 MBq


CT Specifications

  • X RAY ENERGY: 10 – 50 kVp

  • detector: Digital flat panel 2400x2400 pixels

  • SPATIAL RESOLUTION: 90 um

  • MAXIMUM CURRENT: 1 mA

  • FOV: 70x70 mm


SPECT 108 Specifications

  • DETECTOR: Dual head camera system with patented continous CsI(Na) crystal technology

  • SENSITIVITY: 1.800 cps/MBq

  • ENERGY RESOLUTION: 0,18

  • ENERGY RANGE: 30 – 400 keV

  • VARIABLE FOV: 25 – 120 mm

  • SPATIAL RESOLUTION: 0.5 mm

  • COLLIMATORS: A.General Purpose; B. High Energy; C. High Resolution; D. Multipinhole;

  • RECONSTRUCTION: OSEM, Fast Reconstruction


Best in class specifications under real lab conditions


  • Resolution up to 0.7 mm

  • Sensitivity of 12%

  • NEMA NECR peak rates: mouse 560 kcps, rat 330 kcps

  • Unprecedented quantification and dynamic study performance

  • Large axial FOV of 148 mm

  • Cardiac and respiratory gating