应用范围:将蛋白从聚丙烯酰胺凝胶上电转移到膜上
技术参数:
凝胶尺寸:21 x 26 cm
独特穿孔的铂-铌和不锈钢屏幕电极
转移时间:小于一小时
采用穿孔的屏幕电极在转移时能让气泡散发,不会造成转移障碍。
一次可转移尺寸为21x26cm的三块凝胶
缓冲液量非常少,仅需浸透滤纸和膜
自仪器安装验收合格后,提供整机一年免费保修
Parameter | TE 70 Semi-Dry Transfer Unit, 14 × 16 cm |
---|---|
Application | Designed to deliver outstanding electrophoretic transfer results using low current and voltage with a minimal amount of buffer |
Compliance | The product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from GE Healthcare and connected only to other CE labeled GE Healthcare modules or other products as recommended. For regulatory details please see declaration of conformity. |
Depth | 46 cm |
Height | 9 cm |
Includes | 25 sheets of blotting paper, 50 sheets of cellophane, 2 solid masks, masks for 7 x 8 cm and 14 x 16 cm gels. |
Operating Conditions | Indoor use: 4 – 40°C operating conditions: Humidity up to: 80% Altitude up to: 2000 m Installation category: II Pollution degree: 2 |
Output Current | 0.5 A |
Output Voltage | 30 V |
Recommended Power Supply | EPS2A201 |
Weight | 3.7 kg |
Width | 38 cm |
Built-in Power | No |
Gel Size | 14 x 16 cm |
Parameter | TE 77 Semi-Dry Transfer Unit, 21 × 26 cm |
---|---|
Application | Designed to deliver outstanding electrophoretic transfer results using low current and voltage with a minimal amount of buffer |
Compliance | The product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from GE Healthcare and connected only to other CE labeled GE Healthcare modules or other products as recommended. For regulatory details please see declaration of conformity. |
Depth | 46 cm |
Height | 9 cm |
Includes | 25 sheets of blotting paper, 50 sheets of cellophane, solid mask and mask for 14 x 16 cm gels. |
Operating Conditions | Indoor use: 4 – 40°C operating conditions: Humidity up to: 80% Altitude up to: 2000 m Installation category: II Pollution degree: 2 |
Output Current | 0.5 A |
Output Voltage | 30 V |
Recommended Power Supply | EPS 301 |
Weight | 3.7 kg |
Width | 38 cm |
Built-in Power | No |
Gel Size | 21 x 26 cm |
Parameter | TE 70 PWR Semi-Dry Transfer Unit, 14 × 16 cm |
---|---|
Application | Designed to deliver outstanding electrophoretic transfer results using low current and voltage with a minimal amount of buffer |
Compliance | The product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from GE Healthcare and connected only to other CE labeled GE Healthcare modules or other products as recommended. For regulatory details please see declaration of conformity. |
Depth | 46 cm |
Height | 9 cm |
Includes | 25 sheets of blotting paper, 50 sheets of cellophane, 2 solid masks, masks for 7 x 8 cm and 14 x 16 cm gels. |
Input Current | 0.7 A |
Input Voltage | 100 - 240 V |
Operating Conditions | Indoor use: 4 – 40°C operating conditions: Humidity up to: 80% Altitude up to: 2000 m Installation category: II Pollution degree: 2 |
Output Current | 0.5 A |
Output Voltage | 30 V |
Weight | 3.7 kg |
Width | 38 cm |
Built-in Power | Yes |
Gel Size | 14 x 16 cm |
Parameter | TE 77 PWR Semi-Dry Transfer Unit, 21 × 26 cm |
---|---|
Application | Designed to deliver outstanding electrophoretic transfer results using low current and voltage with a minimal amount of buffer |
Compliance | The product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from GE Healthcare and connected only to other CE labeled GE Healthcare modules or other products as recommended. For regulatory details please see declaration of conformity. |
Depth | 46 cm |
Height | 9 cm |
Includes | 25 sheets of blotting paper, 50 sheets of cellophane, solid mask and mask for 14 x 16 cm gels. |
Input Current | 0.7 A |
Input Voltage | 100 - 240 V |
Operating Conditions | Indoor use: 4 – 40°C operating conditions: Humidity up to: 80% Altitude up to: 2000 m Installation category: II Pollution degree: 2 |
Output Current | 0.5 A |
Output Voltage | 30 V |
Weight | 3.7 kg |
Width | 38 cm |
Built-in Power | Yes |
Gel Size | 21 x 26 cm |