Standard models and available pump laser power matrix | ||||
TiF-100ST (standard wavelength range) | TiF-100LW (extended IR range) | |||
Pump laser power | Wavelength tuning | Output power | Wavelength tuning | Output power |
3 W | 740-860 nm | >350 mW аt 800 nm | n/a | n/a |
4 W | 735-870 nm | >500 mW аt 800 nm | n/a | n/a |
5 W | 730-875 nm | >650 mW аt 800 nm | 830-950 nm | >200 mW at 950 nm |
6 W | 725-880 nm | >850 mW аt 800 nm | 830-960 nm | >200 mW at 960 nm |
8 W | 720-885 nm | >1.25 W аt 800 nm | 830-970 nm | >200 mW at 970 nm |
10 W | 715-890 nm | >1.55 W аt 800 nm | 830-980 nm | >150 mW at 980 nm |
It is possible to combine both ranges in a single laser system, please enquire for details. |
General optical specifications | |
Output pulse duration1) | <100 fs |
Spectrum width1) (FWHM) | >8 nm |
Pulse repetition rate (fixed) | 80±10 MHz |
Pump laser | integrated or stand-alone DPSS 532 nm low-noise laser (up to 10 W) |
Beam mode | TEMoo (M^2 <1.2) |
Beam diameter (at 1/e^2) | <2 mm |
Output polarization | linear, horizontal, PER >20 dB |
Beam divergence | <1 mrad |
Long-term stability2) | <0.1% rms |
Noise3) | <0.2% rms |
Physical dimensions (L × W × H) | |
Laser head | 516 × 350 × 118 mm (including integrated pump laser) |
Pump laser control unit | 353 × 360 × 119 mm |
Closed-loop chiller | 430 × 340 × 190 mm |
Environmental and utility specifications | |
Operating temperature | 15-30 °C |
Relative humidity | <60%, non-condensing |
Voltage | single-phase; 100-240 VAC; 50/60 Hz |
Power consumption | <2 kW |
Available configuration packages4) | |
Thermally stabilized monolithic body | included in any package |
Pulse train SMA output with mode-lock LED | included in any package |
“Auto” factory package | - built-in spectrometer - single-touch wavelength tuning w. presets - built-in power meter - active output power stability locking - Windows software with configurable widgets - automatic mode-lock start and monitoring PC requirements: USB 2.0 port, Windows 10 |
“Basic“ factory package (default) | - push-button starter - USB 2.0 wavelength tuning via step-motor slit (via step number information and calibration) PC requirements: USB 2.0 port, Windows 10 |
“Manual” factory package | - push-button starter - manual wavelength tuning slit |
1) - when tuned to 800 nm central wavelength; 2) - after 30 min warm-up with cold start, during 12-hour continuous operation under equal room temperature conditions using recommended stabilized closed-loop chiller with proper capacity and recommended low-noise on-board integrated highly stable pump laser with active power locking; 3) - measured from 10 Hz to 10 MHz; 4) - please select one of the packages for your system; certain features may be tailored or combined differently according to specific customer requirements. |