•SCX and high pH reversed phase fractionation are both orthogonal to low pH C18 LC separation

•Strong cation exchange (SCX) requires sample desalting after fractionation

 

Reproducibly Identify More TMT-labeled Peptides

2017223151420619.jpg

 

•Significantly increase the number of proteins identified and quantified

•The percentage and number of peptides observed in only 1 fraction are within 10% between runs

 

Two New Peptide Quantitation Assays

2017223151452833.jpg

 

Colorimetric peptide assay is more sensitive than BCA

Two New Peptide Quantitation Assays

Thermo Poster Note: Quantitative Peptide Assays for Mass Spectrometry Applications; Haney P. et al

 

Peptide Quantitation Improves MS Reproducibility

2017223151517814.jpg

 

Thermo Poster Note 64604: Quantitative peptide assay for optimized and reproducible sample preparations for mass spectrometry applications; Jiang X. et al

 

Peptide Assays Provide Consistent Quantification

 2017223151546155.jpg2017223151538602.jpg

 

“We really like those peptide quant kits. We find that peptide mass quantitation is directly relevant for determining the amount of analyte we use for LC-MS/MS analyses, phosphopeptide enrichments, and for TMT labeling.

 

Instrument Configuration

 

Introducing A New Powerful Combination

 

Unlock the performance of your MS with incredibly easy chromatography

 

201722315216452.jpg

 

[EASY-nLC™ 1200 HPLC System]

•Industry leading 1200 bar system pressure

•Improved system robustness and easier maintenance

•Temperature control of EASY-Spray columns

•Effortless ultra-high performance for every user, every time

 

2017223152115744.jpg

 

[75cm EASY-Spray™ Column]

•Increased peak capacity

•Even more identifications

•Excellent retention time consistency

•Improved quantitative reproducibility

 

Extend The Performance Of Your MS with 75cm Columns

 

Improved Protein Identifications

2017223152145791.jpg

 

•Peak capacity exceeding 800.

•Deeper proteome coverage with a consistent 5700 protein groups per run.

•9% increase in protein groups over 3 combined runs compared to 50 cm column.

•Identify more proteins per hour – comparable identifications in 120 minutes to a 50 cm column in 240 minutes.

2017223152159735.jpg

 

Increased Quantitative Reproducibility

•Less run-to-run variability 91% identification overlap run to run

• More quantifiable proteins 50% increase in the number of quantifiable proteins with CVs <5%