GSO ISO 9555-3:2014

Measurement of liquid flow in open channels -- Tracer dilution methods for the measurement of steady flow -- Part 3: Chemical tracers


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 GSO ISO 9555-3:2014 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
GSO ISO 9555-3:2014
发布
2014年
发布单位
GSO
当前最新
GSO ISO 9555-3:2014
 
 
适用范围
This part of ISO 9555 deals with the use of chemical tracers in discharge measurements by the dilution method. Apparatus and methods of general application are set out in ISO 9555-1 and are not repeated here, with the exception of those relating specifically to chemical tracers. Chemical tracers have several advantages as follows. a) As with fluorescent tracers, the handling of the tracer follows normal chemical laboratory practice, and no special equipment (e.g. radiation shielding) is required. Care is still required, however, when handling concentrated tracer, to avoid contamination of samples and, with some tracers, for reasons of chemical toxicity. b) In general, chemical tracers are widely available commercially, and may be stored indefinitely. c) Analysis may be possible using laboratory facilities currently used for water quality determination. d) In general, chemical tracers are photochemically stable. The disadvantages of chemical tracers are as follows: a) Their detection limits are relatively high and therefore a larger quantity of tracer is required for each gauging than in the case of radioactive or fluorescent tracers. For practical reasons this may restrict their application to small discharges. However, for certain tracers, reconcentration techniques can permit the measurement of large discharges (of the order of 1 000 m3/s) where conditions of mixing and tracer loss are acceptable. b) With the exception of the conductivity method for sodium choride, the determination ranges of laboratory analysis methods are limited, so dilution of river samples may be necessary before analysis. This limitation means that the constant-rate injection method is preferable for chemical tracers (excepting the conductivity method) since determination of the peak concentrations resulting from a sudden injection would be difficult. c) Natural background levels, particularly of conductivity (resulting from dissolved solids in natural waters), may be high and variable, and this necessitates the use of a larger amount of tracer than would be apparent from a consideration of detection limits only. d) It is not possible to use a carrier, as in the case of radioactive tracers, and losses by adsorption may be serious in some cases.

GSO ISO 9555-3:2014相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号