CSA C22.2 No.31-2023

Switchgear assemblies


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CSA C22.2 No.31-2023 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
CSA C22.2 No.31-2023
发布
2023年
发布单位
SCC
当前最新
CSA C22.2 No.31-2023
 
 
代替标准
29.130.20
被代替标准
CAN/CSA C22.2 No. 31-18
适用范围
1 Scope 1.1 This Standard applies to deadfront indoor enclosed and outdoor enclosed assemblies of switchgear devices such as a) switches; b) interrupting devices; c) air circuit breakers; d) power circuit breakers; and e) control, metering, protective, and regulating equipment with associated interconnections and supporting structures. 1.2 This Standard covers equipment with a nominal voltage of 46 kV or less that is intended to be used a) in accordance with the Canadian Electrical Code, Part I; b) in non-hazardous locations; c) for controlling and protecting the power from generators or other sources; and d) for supplying electrical energy to power and lighting circuits. 1.3 This Standard does not apply to a) switchboards for power distribution (see CSA C22.2 No. 244); b) switchboards for communication circuits; c) panelboards (see CSA C22.2 No. 29); d) industrial control equipment (see CSA C22.2 No. 14); e) low-voltage assemblies consisting of separately supported enclosed switches; f) enclosed circuit breakers (see CSA C22.2 No. 5); g) service meters with interconnection between them enclosed in raceways; and h) individual low-voltage switchgear and controlgear switching devices such as contactors or proximity switches (see CSA C22.2 No. 60947 series and Note 2 below). Notes: 1) Manufacturers and installers of switchgear assemblies approved under this Standard should take due note of the Canadian Electrical Code, Part I, with respect to the location of switchgear devices in areas where certain components might not be acceptable. 2) The terms “switchgear” and “switchgear assemblies” used within the content of this Standard refer to assemblies primarily intended to provide protection and control of either low- or high-voltage feeder and sub- feeder circuits in connection with the generation, transmission, distribution, and conversion of electric power. These terms should not be confused with the IEC terms “switchgear” and “controlgear” used within the context of the CSA C22.2 No. 60947 series of standards which cover individual or combinations of individual low-voltage switching devices intended for the control, measurement, or regulation of energy-consuming equipment. 1.4 Clauses 2to 6apply to all switchgear assemblies and are supplemented and amended by a) Clause 7for low-voltage switchgear assemblies; and b) Clause 8for high-voltage switchgear assemblies. Note: See Annex Ffor additional requirements applicable for pressurized gas insulated switchgear. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

CSA C22.2 No.31-2023相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号