CAN/CSA-C22.2 No.60947-7-4-2018

Low-voltage switchgear and controlgear — Part 7-4: Ancillary equipment — PCB terminal blocks for copper conductors


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CAN/CSA-C22.2 No.60947-7-4-2018 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
CAN/CSA-C22.2 No.60947-7-4-2018
发布
2018年
发布单位
SCC
当前最新
CAN/CSA-C22.2 No.60947-7-4-2018
 
 
代替标准
CAN/CSA-C22.2 No. 60947-7-4:18
被代替标准
29.130.20
适用范围
1.1 Scope This part of IEC 60947 specifies requirements for PCB terminal blocks primarily intended for industrial or similar use. Mounting and fixing on the printed circuit board is made by soldering, press-in or equivalent methods to provide electrical and mechanical connection between copper conductors and the printed circuit board. This standard applies to PCB terminal blocks intended to connect copper conductors, with or without special preparation, having a cross-section between 0,05 mm2 and 300 mm2 (AWG 30/600 kcmil), intended to be used in circuits of a rated voltage not exceeding 1 000 V a.c. up to 1 000 Hz or 1 500 V d.c. NOTE 1 Large cross section terminal blocks are dedicated to specific design of high current PCBs. The range up to 300 mm2 is kept to cover any possible application. Examples of high current PCBs and PCB terminal blocks are shown in Annex C. NOTE 2 AWG is the abbreviation of “American Wire Gage” (Gage (US) = Gauge (UK)); kcmil = 1 000 cmil; 1 cmil = 1 circular mil = surface of a circle having a diameter of 1 mil; 1 mil = 1/1 000 inch. This standard may be used as a guide for special types of PCB terminal blocks with components, such as disconnect units, integrated cartridge fuse-links and the like. If applicable, in this standard the term “clamping unit” is used instead of “terminal”. This is taken into account in case of references to IEC 60947-1. 1.1DV D2 Modification by adding the following: 1.1DV.1 This standard also applies to terminal blocks that have insulation piercing or displacement clamping units. 1.1DV.2 The wire range for terminal blocks covered by this standard include 0,051 mm2 to 300 mm2 (30 AWG to 600 kcmil) copper conductors and 3,31 mm2 to 300 mm2 (12 AWG to 600 kcmil) aluminum conductors. See Annex DVA for aluminum requirements. In Mexico, 3,31 mm2 (12 AWG), 5,26 mm2 (10 AWG), and 8,37 mm2 (8 AWG) aluminum conductors are not allowed. 1.1DV.3 The voltage range includes up to 1500 Vac and 1500 Vdc.

CAN/CSA-C22.2 No.60947-7-4-2018相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号