1.1  This specification lists code word names for bare overhead electrical conductors that are recognized in North America. A procedure has been outlined for adding additional code word names to this standard. Code word names have been in existence for many years describing various conductor constructions used in North America, Europe and elsewhere in the world. Their origin is not clearly understood. The historical basis of this standard originates from code word names developed years ago by member utility companies that participated in the US Aluminum Association, Technical Committee. 1.2  The code word names are grouped into tables of like constructions. The code word name construction can be modified with the use of suffix modifiers that identify additional construction variations. For example the type of steel core material used in an ACSR type of conductor may be modified with the letter designation “/GA3” denoting the strength and type of coating for the steel core material. 1.3  The tables provide the applicable ASTM standard for which the conductor construction may be built to. For conductors that are unique to use in Canada, the applicable CSA International standard is referenced. 1.4  The tables include code word names that are referenced in Canadian CSA and European CENELEC standards. The information is believed to be correct however the user of this document is encouraged to consult the applicable CSA or CENELEC standard for confirmation. 1.5  This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

标准号
ASTM B1006-17(2023)
发布
2023年
发布单位
美国材料与试验协会
当前最新
ASTM B1006-17(2023)
 
 

ASTM B1006-17(2023)相似标准


推荐

变电站、输电线路环保标准、豁免范围及相关距离要求汇总

1《电力设施保护条例》的规定:第十条 电力线路保护区:(一)架空电力线路保护区:导线边线向外侧水平延伸并垂直于地面所形成的两平行面内的区域,在一般地区各级电压导线的边线延伸距离如下:1-10千伏   5米35-110千伏  10米154-330千伏 15米500千伏 20米在厂矿、城镇等人口密集地区,架空电力线路保护区的区域可略小于上述规定。...

环评评价范围内工程拆迁的建筑物不列为环境敏感目标,不评价!环保验收调查范围内有公众居住等建筑物都应列

表 3输变电工程电磁环境影响评价范围  分类 电压等级评价范围变电站、换流站、 开关站、串补站线路架空线路地下电缆 交流110kV站界外30m边导线地面投影外两侧各30m 电缆管廊两侧边缘各 外延5m(水平距离)220~330kV站界外40m边导线地面投影外两侧各40m500kV及以上站界外50m边导线地面投影外两侧各50m直流±100kV及以上站界外50m极导线地面投影外两侧各50m4.7.2生态环境影响评价范围...

【华恒仪表冠名】贵州省监督抽查32批次电线电缆产品 合格率100%

架空绝缘电缆》; GB/T 9330.2-2008 《塑料绝缘控制电缆 第2部分:聚氯乙烯绝缘和护套控制电缆》;CCGF 708.1—2015《电力电缆》等标准要求进行检验。...

环保:用电汇总,常见错误

2、施工现场配电线路(1)必须采用绝缘导线;(2)导线截面应满足计算负荷要求和末端电压偏移 5%的要求;(3)电缆配线应采用有专用保护线的电缆;(4)架空线路的导线截面一般场所不得小于100m㎡(钢线)或16 m㎡(铝线),跨越公路、河道和在电力线路挡距内不得小于16 m㎡(钢线)或25 m㎡铝线;(5)配电线路至配电装置的电源进线必须做固定连接,严禁做活动连接;(6)配电线路的绝缘电阴值不得小于1000ΩW...