GSO IEC 60079-0:2024
爆炸性环境 第0部分:设备 一般要求

Explosive atmospheres - Part 0: Equipment - General requirements


标准号
GSO IEC 60079-0:2024
发布
2024年
发布单位
GSO
当前最新
GSO IEC 60079-0:2024
 
 
适用范围
IEC 60079-0:2017 is also available as IEC 60079-0:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60079-0:2017 specifies the general requirements for construction, testing and marking of Ex Equipment and Ex Components intended for use in explosive atmospheres. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it may be assumed that Ex Equipment can be operated are: -temperature –20 °C to +60 °C; -pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and -air with normal oxygen content, typically 21 % v/v. This part of IEC 60079 and other standards supplementing this standard specify additional test requirements for Ex Equipment operating outside the standard temperature range, but further additional consideration and additional testing may be required for Ex Equipment operating outside the standard atmospheric pressure range and standard oxygen content. Such additional testing may be particularly relevant with respect to Types of Protection that depend on quenching of a flame such as ‘flameproof enclosures “d”’ (IEC 60079-1) or limitation of energy, ‘intrinsic safety “i”’ (IEC 60079-11). This seventh edition cancels and replaces the sixth edition, published in 2011. This edition constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 7.0 and the previous edition of the document. Keywords: Ex Equipment and Ex Components intended for use in explosive atmospheres The contents of the interpretation sheet 1 of April 2019, of the interpretation sheet 2 of June 2019 and the corrigendum 1 of January 2020 have been included in this copy.

GSO IEC 60079-0:2024相似标准


推荐

防爆空调的标准

  防爆空调产品必需符合国家相关防爆标准才允许进入市场,国家公布的防爆类产品执行标准有;  GB3836.1-2000 爆炸性气体环境用电气设备 1部分:通用要求  GB3836.2-2000 爆炸性气体环境用电气设备 2部分:隔爆型“d”  GB3836.4-2000 爆炸性气体环境用电气设备 2部分:本安型“ib”  GB3836.9-2006 爆炸性气体环境用电气设备 9部分:浇封型“...

防爆空调的使用场地主要有

  一、危险场所的危险程度选择防爆空调   根据GB3836.14-2000《爆炸性气体环境用电气设备14部分:危险场所分类》,危险场所可分为0区、1区和2区。  (a)0区:爆炸性气体环境连续出现或长期存在的场所。  (b)1区:正常运行时可能出现爆炸性气体环境的地方。  (c)2区:正常运行时,爆炸性气体环境是不可能的,如果发生,也是偶尔发生,只存在很短时间。  ...

防爆空调的概述

标准  防爆空调产品必需符合国家相关防爆标准才允许进入市场,国家公布的防爆类产品执行标准有;  GB3836.1-2000 爆炸性气体环境用电气设备 1部分:通用要求  GB3836.2-2000 爆炸性气体环境用电气设备 2部分:隔爆型“d”  GB3836.4-2000 爆炸性气体环境用电气设备 2部分:本安型“ib”  GB3836.9-2006 爆炸性气体环境用电气设备 9部分:浇封型...

防爆空调的概述及特点

标准  防爆空调产品必需符合国家相关防爆标准才允许进入市场,国家公布的防爆类产品执行标准有;  GB3836.1-2000 爆炸性气体环境用电气设备 1部分:通用要求  GB3836.2-2000 爆炸性气体环境用电气设备 2部分:隔爆型“d”  GB3836.4-2000 爆炸性气体环境用电气设备 2部分:本安型“ib”  GB3836.9-2006 爆炸性气体环境用电气设备 9部分:浇封型...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号