GSO ISO 17665-1:2014

Sterilization of health care products -- Moist heat -- Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices


GSO ISO 17665-1:2014 发布历史

GSO ISO 17665-1:2014由GSO 发布于 2014-12-25。

GSO ISO 17665-1:2014在国际标准分类中归属于: 11.080.01 消毒和灭菌综合。

GSO ISO 17665-1:2014 的最新版本是哪一版?

最新版本是 GSO ISO 17665-1:2014

GSO ISO 17665-1:2014的历代版本如下:

 

1.1 Inclusions 1.1.1 This part of ISO 17665 specifies requirements for the development, validation and routine control of a moist heat sterilization process for medical devices. NOTE Although the scope of this part of ISO 17665 is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other health care products. 1.1.2 Moist heat sterilization processes covered by this part of ISO 17665 include but are not limited to: a) saturated steam venting systems; b) saturated steam active air removal systems; c) air steam mixtures; d) water spray; e) water immersion. NOTE See also Annex E. 1.2 Exclusions 1.2.1 This part of ISO 17665 does not specify requirements for development, validation, and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents. NOTE See also ISO 22442-1, ISO 22442-2 and ISO 22442-3. 1.2.2 This part of ISO 17665 does not apply to those sterilization processes that are based on a combination of moist heat with other biocidal agents (e.g. formaldehyde) as the sterilizing agent. 1.2.3 This part of ISO 17665 does not detail a specified requirement for designating a medical device as “sterile.” NOTE Attention is drawn to national or regional requirements for designating medical devices as “sterile.” See, for example, EN 556-1 or ANSI/AAMI ST67. 1.2.4 This part of ISO 17665 does not specify a quality management system for the control of all stages of production of medical devices. NOTE It is not a requirement of this part of ISO 17665 to have a complete quality management system during manufacture, but the elements of a quality management system that are the minimum necessary to control the sterilization process are normatively referenced at appropriate places in the text (see, in particular, Clause 4). Attention is drawn to the standards for quality management systems (see ISO 13485) that control all stages of production of medical devices, including the sterilization process. Regional and national regulations for the provision of medical devices might require implementation of a complete quality management system and the assessment of that system by a third party. 1.2.5 This part of ISO 17665 does not specify requirements for occupational safety associated with the design and operation of moist heat sterilization facilities. NOTE Requirements for operational safety are specified in IEC 61010-2-040. Additionally, safety regulations exist in some countries.

标准号
GSO ISO 17665-1:2014
发布
2014年
发布单位
GSO
当前最新
GSO ISO 17665-1:2014
 
 

GSO ISO 17665-1:2014相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号