60332-1-2-2004
Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame (Edition 1.0; Replaces IEC 60332-1:1993)

Essais des c?bles électriques et à fibres optiques soumis au feu Partie 1-2: Essai de propagation verticale de la flamme sur conducteur ou c?ble isolé Procédure pour flamme à prémélange de 1 kW (Edition 1.0; Replaces IEC 60332-1:1993)


说明:

  • 此图仅显示与当前标准最近的5级引用;
  • 鼠标放置在图上可以看到标题编号;
  • 此图可以通过鼠标滚轮放大或者缩小;
  • 表示标准的节点,可以拖动;
  • 绿色表示标准:60332-1-2-2004 , 绿色、红色表示本平台存在此标准,您可以下载或者购买,灰色表示平台不存在此标准;
  • 箭头终点方向的标准引用了起点方向的标准。

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 60332-1-2-2004 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
60332-1-2-2004
发布日期
2004年07月01日
实施日期
2015年07月30日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEC - International Electrotechnical Commission
引用标准
30
适用范围
This part of IEC 60332 specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable@ or optical fibre cable@ under fire conditions. The apparatus is given in IEC 60332-1-1.NOTE 1 Testing to IEC 60332-1-2 may be performed simultaneously with that to IEC 60332-1-3 if required.Recommended requirements for performance are given in Annex A.IEC 60332-1-2 specifies the use of a 1 kW pre-mixed flame and is for general use@ except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0@5 mm? total cross-section because the conductor melts before the test is completed@ or for the testing of small optical fibre cables because the cable is broken before the test is completed. In these cases@ the procedure given in IEC 60332-2-2 is recommended.NOTE 2 Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation@ it is recommended that wherever the risk of propagation is high@ for example in long vertical runs of bunches of cables@ special installation precautions should also be taken. It cannot be assumed that because the sample of cable complies with the performance requirements recommended in this standard@ that a bunch of cables will behave in a similar manner. (See IEC 60332-3 series.)




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号