60601-2-1 AMD 2-1990
Modification 2 a la Publication 601-2-1 (1981) Safety of Medical Electrical Equipment Part 2: Particular Requirements for Medical Electron Accelerators in the Range 1 MeV to 50 MeV Section One: General Section Two: Radiation Safety for Equipment (Edition

Amendment 2 to Publication 601-2-1 (1981) Securite des appareils electromedicaux Deuxieme partie: Regles particulieres pour accelerateurs medicaux d'electrons dans la gamme 1 MeV a 50 MeV - Section Un: Generalites Section Deux: Securite radiologique des a


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 60601-2-1 AMD 2-1990 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
60601-2-1 AMD 2-1990
发布日期
1990年02月01日
实施日期
2014年06月25日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEC - International Electrotechnical Commission
引用标准
50
适用范围
The test procedures described in this amendment are classified in three grades: GRADE A Inspection of the analysis of equipment design provided by the manufacturer as related to the specified safety provisions. GRADE B Visual inspection@ functional test or measurement on the equipment. The test procedures are specified by this amendment to the Particular Standard. The test procedures are based only on operating states (including fault condition states) achievable without interference with the circuitry or construction of the equipment. GRADE C Functional test or measurement on the equipment. The test procedure shall be specified by the manufacturer in the ACCOMPANYING DOCUMENTS in accordance with the principlestated in this amendment to the Particular Standard. The test procedure may involve operating states which require interference with the circuity or construction of theequipment. In such cases of interference@ the work should be personnel or under the direct supervision or approval of the manufacture's personnel. Test procedures specified by the manufacturer shall include instructions on how to reset the equipment into the primary condition after the execution of the tests@ and how this condition shall be verified. Test Procedures specified by the manufacturer shall include the test condition (e.g. GANTRY angular Position@ NOMINAL ENERGY@ RADIATION TYPE). Test procedures specified by the manufactures shall either: a) Generate the described fault condition or@ if not practicable b) As near as practicable to the source of the signal that would be produced in a fault condition@ simulate this signal. The manufacture shall demonstrate in the ACCOMPANYING DOCUMENTS by results of design analysis or experiment that the test signal accurately simulates the signal that would be produced in the fault condition. Note. ?C In special cases@ one test signal may simulate more than one fault condition.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号