GSO ASTM C336:2011由GSO 发布于 2011-04-12。
GSO ASTM C336:2011在国际标准分类中归属于: 81.040.10 原材料和未加工的玻璃。
GSO ASTM C336:2011 用纤维伸长率测定玻璃塑化点和应力点的标准测试方法的最新版本是哪一版?
最新版本是 GSO ASTM C336:2011 。
1.1 This test method covers the determination of the annealing point and the strain point of a glass by measuring the viscous elongation rate of a fiber of the glass under prescribed condition. 1.2 The annealing and strain points shall be obtained by following the specified procedure after calibration of the apparatus using fibers of standard glasses having known annealing and strain points, such as those specified and certified by the National Institute of Standards and Technology (NIST)2 (see Appendix X1). 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
十、大力总伸长率Agt和大力非比例伸长率Ag 的测定: (1) 图解方法(包括自动方法):1、引伸计标距应等于或近似等于试样标距。2、建议:当大力总延伸率< 5 %时,使用不劣于1 级引伸计; ≥5 %时,使用不劣于2 级引伸计。试验时纪录力-延伸曲线或采集力-延伸数据,直至超过大力点。取大力点的总延伸计算A gt 。...
ASTM D-2343标准规定了适用于玻璃纤维的拉伸试验方法;ASTM D-897标准中规定了适用于粘结剂的拉伸试验方法;ASTM D-412标准中规定了硬橡胶的拉伸试验方法。塑性是指金属材料在载荷作用下产生塑性变形而不致破坏的能力,常用的塑性指标是延伸率和断面收缩率。延伸率又叫伸长率,是指材料试样受拉伸载荷折断后,总伸长度同原始长度比值的百分数,用δ表示。...
夹具内表面的材料和设计应使试样达到zui大负荷时,与夹具之间的滑动距离不超过夹具初始距离的1%。伸长率的测定:通过监视夹具的分离或者通过传感器监测试样上的两个固定点之间的距离测定。测厚仪:详细资料见KD-352皮革厚度测定仪。游标卡尺:zui小精度0.1mm操作程序:在每个试样的粒面和肉面各选取三个位置,用游标卡尺测量试样的宽度(到0.1mm)。...
夹具内表面的材料 和设 计 应 使 试 样 达 到zui大负荷时,与夹具之间的滑动距离不超过夹具初始距离的I% 4.2 伸长测定装置 通 过 监 视夹具的分离或者通过传感器监测试样上的两个固定点之间的距离测定。 4.3 测厚仪 符合 QB /T2 709-2005的规定。...