EN ISO 16526-2:2020
无损检测.X射线管电压的测量与评价.第2部分:用后过滤器的恒定校验方法

Non-destructive testing - Measurement and evaluation of the X-ray tube voltage - Part 2: Constancy check by the thick filter method (ISO 16526-2:2011)

2020-09

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 EN ISO 16526-2:2020 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
EN ISO 16526-2:2020
发布
2020年
发布单位
欧洲标准化委员会
当前最新
EN ISO 16526-2:2020
 
 
适用范围
ISO 16526-2:2011 specifies a constancy check of a X-ray system where mainly the X-ray voltage is checked and also the tube current and the constitution of the target which can be changing due to ageing of the tube. The thick filter method is based on a measurement of the dose rate behind a defined thick filter using defined distances between the X-ray tube, the filter and the measuring device. This method is very sensitive to changes of the voltage, but it does not provide an absolute value for the X-ray tube voltage. Therefore, a reference value is needed and, it is recommended to find this reference, for example, within the acceptance test of the system. The thick filter method is a rather simple technique and may be applied by the operator of an X-ray system to perform regularly a constancy check of the system. The method can also be applied for consistency checks after changing components which may affect the X-ray tube voltage. This method can be applied for all types of X-ray systems, i. e. for constant potential, half wave and impulse wave generators with a tube current larger than 1 mA.

EN ISO 16526-2:2020相似标准


推荐

【产品推介】Airstream A2型二级生物安全柜 AC2-S系列

自带电压波动补偿功能,在190~250V宽电压波动范围内仍可保持恒定风速。通过国际EN 12469认证。Esco Airstream®A2型二级生物安全柜 (S系列) 表面涂有Esco ISOCIDE™抗菌涂层,可有效抑制柜体表面的细菌滋生。...

《产品质量信息系统 分类描述》等107项推荐性国家标准公开征求意见

T-610液态金属物理性能测定方法  1部分:密度测定制订2021/4/103520162502-T-469家电噪声声品质工效学测评  1部分:冰箱制订2021/4/103620193020-T-604管道用Y型铸铁过滤器制订2021/4/103720202847-T-469无损检测  微磁检测 总则制订2021/4/103820202848-T-469无损检测  非铁磁性金属材料脉冲涡流检测制订...

《多晶X射线衍射技术应用》-12(3章 多晶X射线衍射仪)

常用工频高压发生器比较笨重,但成本较低,有三种基本电路形式(图3.19)。X线管工作电压(管压)和阳极电流(管流)均有稳定电路控制,以保持X线管发生X射线强度高度稳定。管压和管流控制多采用“二次侧检测,一次侧控制”方式,即通过检测高压发生器输出侧实际施加于X线管工作电压kV和X线管阳极电流mA值来反馈控制高压发生器输入侧输入电压,使实际kV和mA值设定值相等。...

【产品推介】AirstreamA2型二级生物安全柜 AC2-S系列

Esco,给您更好选择!为您推荐最先进高效节能,低噪音,舒适紧凑生物安全柜。一、产品简介Esco Airstream系列A2型二级生物安全柜 (S系列) 是一种在实验室和工业生产中为操作者、样品和环境保护提供全面保护高效解决方案。采用高效节能EDC CM风机,传统AC风机相比可节约高达70%用电量。自带电压波动补偿功能,在190~250V宽电压波动范围内仍可保持恒定风速。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号