GSO IEC 61050:2014
空载输出电压超过1000V的管状放电灯变压器(俗称霓虹灯变压器) 一般要求和安全要求

Transformers for tubular discharge lamps having a no-load output voltage exceeding 1000 V (generally called neon-transformers). General and safety requirements


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 GSO IEC 61050:2014 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
GSO IEC 61050:2014
发布
2014年
发布单位
GSO
当前最新
GSO IEC 61050:2014
 
 
适用范围
This International Standard is applicable to independent and built-in single-phase transformers with separate input and output windings, for use on a.c. supply up to 1 000 V at 50 Hz or 60 Hz, to supply and stabilize cold cathode tubular lamps (or assemblies of such lamps) having a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V (see notes 1 and 2) and intended for lighting and for electric advertising signs, light signals and similar purposes. NOTE - Different requirements apply in Japan and North America, which will be the subject of a future annex to this standard. In order to ensure the safety of these transformers, it is necessary to check their performance. But since no standardization of the characteristics of these lamps exists, reference loads are defined in this standard to ensure reproducible test results. In locations where special conditions prevail, as in ships, vehicles and the like, and in dangerous locations, for example, where explosions are liable to occur, special constructions may be required. This standard does not apply to transformers intended for the supply of lamps or tubes such as low-pressure or high-pressure sodium vapour lamps, high-pressure mercury vapour lamps, halogen lamps, xenon lamps, hot cathode tubular fluorescent lamps, special lamps for document copying machines, etc. This standard does not apply to auto-transformers and electronic convertors This standard may, nevertheless, serve as a guide for transformers with applications other than those specified in the scope, for instance transformers for photographic lamps, as long as their characteristics remain within the framework of those specified in the scope and they are not the subject of a particular IEC standard. Capacitors shall comply with IEC 1048, where applicable. NOTES 1 See definition of 2.9 2 Other limits may be specified in national standards or wiring rules, see annex A. Tests in this standard are type tests. Guidance on routine testing is given in annex C.

GSO IEC 61050:2014相似标准


推荐

干式变压器连接方式

3、输入、输出三相电源线应按变压器接线板母线颜色黄、绿、红分别接A相、B相、C相,零线应与变压器压器中性零线相接,接地线、变压器外壳以及变压器中心点相连接.平常我们说地线与零线都是从变压器中性点引出。(如变压器有机箱应与箱体地线标志对应相连接)。  检查输入输出线,确认正确无误。  4、先空载通电,观察测试输入输出电压符合要求。...

变压器参数试验台操作方法

适用于供配电系统,变压器制造厂,工矿等企业等单位。该试验台集变压器多项试验功能于一体,具有变压器各项试验控制、监视、测量、保护等多种功能。该系统具有操作简单直观、性能可靠、测量数据准确等特点。能准确测量变压器空载损耗、空载电流、负载损耗、阻抗电压、变比组别、绕组直流电阻;并自动换算到额定电压空载损耗、额定电流下和温度下负载损耗和阻抗电压百分比。...

试验三倍频变压器装置特点

广泛用于电力系统35~220kV等级串激式电压互感器交流耐压试验,以考核互感器主、从绝缘强度,同时也可对电机及小型变压器绕组进行感应试验;也可作为短时运行150Hz电源用。技术指标输入电压 380V 50Hz 正弦波输出电压 250V- 1000V 150Hz 波形失真≤5%输出容量 3kVA、5kVA、10kVA、20kVA、50kVA空载运行时间≤5分钟负载运行时间 40~60s...

输出变压器相关介绍

因此,检测行输出变压器技术依然值得探讨。 一、以空载电流大小判断行输出变压器好坏 和普通电源变压器一样,行输出变压器也有空载电流。如果行输出变压器正常,内部没有短路,其空载电流非常小;如果内部有短路,特别是次级线圈有短路,空载电流就会很大。因此短路是行输出变压器最常见典型故障。 测量行输出变压器空载电流,就要有一个能产生频率为15625Hz电源。...