EN 15502-2-1:2022
燃气中央供暖锅炉2 -1部分:具体标准C型电器和B2型,B3和B5电器的名义热输入不超过1 000 kw

Gas-fired central heating boilers - Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW


EN 15502-2-1:2022 发布历史

EN 15502-2-1:2022由欧洲标准化委员会 IX-CEN 发布于 2022-09-21,并于 2022-12-31 实施,于 2025-09-30 废止。

EN 15502-2-1:2022在国际标准分类中归属于: 27.060.30 锅炉和热交换器。

EN 15502-2-1:2022的历代版本如下:

  • 2022年 EN 15502-2-1:2022 燃气中央供暖锅炉2 -1部分:具体标准C型电器和B2型,B3和B5电器的名义热输入不超过1 000 kw
  • 2016年 EN 15502-2-1:2012+A1:2016 燃气集中供暖锅炉-第2-1部分:额定热输入不草果1000kW的C型电气用具和B2,B3及B5型电气用具的具体标准
  • 2012年 EN 15502-2-1:2012 燃气中央供暖锅炉2 -1部分:具体标准C型电器和B2型,B3和B5电器的名义热输入不超过1 000 kw

 

This document specifies the requirements and test methods, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as "boilers". This document is intended to be used in conjunction with EN 15502-1:2021. This document covers gas-fired central heating boilers from the types C1 up to C(11) and the types B2, B3 and B5: NOTE 1 For further background information on appliance types see EN 1749:2020. a) that have a nominal heat input (on the basis of net calorific value) not exceeding 1 000 kW; b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021; c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation; d) where the maximum operating pressure in the water circuit does not exceed 6 bar; e) which can give rise to condensation under certain circumstances; f) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler"; if no declaration is given the boiler is to be considered a "standard boiler"; g) which are intended to be installed inside a building or in a partially protected place; h) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit; i) which are designed for either sealed water systems or for open water systems; j) which are either modular boilers, or non-modular boilers. k) which are from the types C(10) that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa, and C(11) that have condensing boiler modules that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa. NOTE 2 This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction needs to be assessed. An example of an assessment methodology, based upon risk assessment, is given in Clause 11. This document does not cover all the requirements for: aa) appliances above 1 000 kW; ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021); ac) appliances using flue dampers; ad) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71, C81, C(12) and C(13); ae) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW; af) appliances incorporating flexible plastic flue liners; ag) C(10) boilers: 1) without a gas-air ratio control, or 2) which are non-condensing appliances, or 3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min)); ah) C(11) boilers that have boiler modules: 1) without a gas-air ratio control, or 2) which are non-condensing appliances, or 3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min)); ai) appliances intended to be connected to a flue having mechanical extraction; aj) surface temperatures of external parts particular to children and elderly people; ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas; al) appliances equipped with an adaptive combustion control function (ACCF); am) boilers intended to be installed in areas accessible to elderly people and children.

标准号
EN 15502-2-1:2022
发布
2022年
发布单位
欧洲标准化委员会
当前最新
EN 15502-2-1:2022
 
 

EN 15502-2-1:2022相似标准


推荐

中消会消费类电器团体标准燃气采暖热水炉供暖系统 燃气采暖热水炉》正式发布

标准中增加了绿色报告、整机可靠性、热水性能评价等项目,提升了燃气系统密封性能要求、热效率要求、负荷设计制造精度要求,降低了器具表面温升、运行噪声(额定输入≤28 kW时,噪声≤48 dB(A))、NOx、COα=1排放指标,使燃气采暖热水炉产品整体性能指标相较于国家标准更严格,为企业生产高端燃气采暖热水炉产品提供了依据。...

除湿机性能如何?

),如输入功率为0.163kW亚都除湿机(标称型号:C121B),其单位输入功率除湿量为1.57 kg/(h·kW),而输入功率为0.209kW小熊除湿机(标称型号:CSJ-A02G1),其单位输入功率除湿量仅为1.02 kg/(h·kW),两者相差超过50%。...

市场监管总局2021年第41号公告

4.特种气瓶包括纤维缠绕气瓶(B3)、低温绝热气瓶(B4)、内装填料气瓶(B5)。5.覆盖关系:A1级覆盖A2、D级,A2C1C2级覆盖D级。6.取得A5级压力容器制造许可单位可以制造与其产品配套中低压压力容器。制造单位许可安全附件制造爆破片装置1.安全阀(A、B)2.紧急切断阀(A、B)3.燃气气瓶阀门(不含车用燃气阀门)1.安全阀、紧急切断阀许可参数级别见注三。...

最新特种设备生产单位许可目录

4.特种气瓶包括纤维缠绕气瓶(B3)、低温绝热气瓶(B4)、内装填料气瓶(B5)。5.覆盖关系:A1级覆盖A2、D级,A2C1C2级覆盖D级。6.取得A5级压力容器制造许可单位可以制造与其产品配套中低压压力容器。制造单位许可安全附件制造爆破片装置1.安全阀(A、B)2.紧急切断阀(A、B)3.燃气气瓶阀门(不含车用燃气阀门)1.安全阀、紧急切断阀许可参数级别见注三。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号